General Electric (Japan)

Type
CompanyLocations
Tokyo, JapanRelationships
Latest Publications
- Open Access
- 11 May 2026
- Published by Wiley in Magnetic Resonance in Medicine
DynaTOF : Time‐Resolved Noncontrast Cerebral MR Angiography Using Spatially Modulated RF Saturation
Purpose: To develop a time‐resolved extension of three‐dimensional time‐of‐flight MR angiography, termed Dynamic TOF (DynaTOF), that exploits intrinsic RF saturation behavior to enable noncontrast visualization of cerebrovascular hemodynamics. Methods: DynaTOF was implemented by varying flip angle, repetition time (TR), and slab‐selective RF excitation profile to modulate longitudinal magnetization saturation and encode relative inflow timing. Data were acquired using a short‐TR protocol combined with deep‐learning reconstruction to ensure scan efficiency. Five healthy volunteers underwent DynaTOF and pulsed arterial spin labeling (PASL) MRA. Five patients with intracranial arteriovenous malformations (AVMs) were scanned to evaluate clinical feasibility and compare temporal patterns with digital subtraction angiography (DSA). Analyses included inflow‐time characterization, cross‐correlation with PASL, region‐of‐interest assessment of arterial, nidus, and venous structures, as well as apparent SNR and contrast‐to‐noise ratio (CNR) quantification. Results: In healthy volunteers, DynaTOF exhibited predictable parameter‐dependent inflow behavior and qualitative agreement with PASL‐derived inversion‐time dynamics. Apparent arterial SNR and CNR maxima were slice‐position dependent, shifting from higher flip angles (20°–30°) at the slab entrance to lower angles (7°–15°) distally. In AVM patients, DynaTOF delineated arterial‐to‐nidus‐to‐early‐venous transitions consistent with DSA, while venous depiction was attenuated for horizontal or curved‐flow vessels due to the directional dependence of TOF‐based inflow contrast. Short‐TR acquisition with deep‐learning reconstruction enabled single‐slab imaging with a voxel size of 0.5 × 0.7 × 0.8 mm 3 in approximately 1 min, supporting flexible parameter sweeps within routine clinical time constraints. Conclusion: DynaTOF offers a noninvasive approach for time‐resolved characterization of cerebrovascular flow while preserving TOF‐like spatial resolution.
- 11 May 2026
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessDynaTOF : Time‐Resolved Noncontrast Cerebral MR Angiography Using Spatially Modulated RF Saturation
Purpose: To develop a time‐resolved extension of three‐dimensional time‐of‐flight MR angiography, termed Dynamic TOF (DynaTOF), that exploits intrinsic RF saturation behavior to enable noncontrast visualization of cerebrovascular hemodynamics. Methods: DynaTOF was implemented by varying flip angle, repetition time (TR), and slab‐selective RF excitation profile to modulate longitudinal magnetization saturation and encode relative inflow timing. Data were acquired using a short‐TR protocol combined with deep‐learning reconstruction to ensure scan efficiency. Five healthy volunteers underwent DynaTOF and pulsed arterial spin labeling (PASL) MRA. Five patients with intracranial arteriovenous malformations (AVMs) were scanned to evaluate clinical feasibility and compare temporal patterns with digital subtraction angiography (DSA). Analyses included inflow‐time characterization, cross‐correlation with PASL, region‐of‐interest assessment of arterial, nidus, and venous structures, as well as apparent SNR and contrast‐to‐noise ratio (CNR) quantification. Results: In healthy volunteers, DynaTOF exhibited predictable parameter‐dependent inflow behavior and qualitative agreement with PASL‐derived inversion‐time dynamics. Apparent arterial SNR and CNR maxima were slice‐position dependent, shifting from higher flip angles (20°–30°) at the slab entrance to lower angles (7°–15°) distally. In AVM patients, DynaTOF delineated arterial‐to‐nidus‐to‐early‐venous transitions consistent with DSA, while venous depiction was attenuated for horizontal or curved‐flow vessels due to the directional dependence of TOF‐based inflow contrast. Short‐TR acquisition with deep‐learning reconstruction enabled single‐slab imaging with a voxel size of 0.5 × 0.7 × 0.8 mm 3 in approximately 1 min, supporting flexible parameter sweeps within routine clinical time constraints. Conclusion: DynaTOF offers a noninvasive approach for time‐resolved characterization of cerebrovascular flow while preserving TOF‐like spatial resolution.
- 12 May 2025
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 52 (4) , 439-440
Sonographic evaluation of vascular normalization induced by lenvatinib in a patient with hepatocellular carcinoma
- 12 May 2025
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 52 (4) , 439-440
Sonographic evaluation of vascular normalization induced by lenvatinib in a patient with hepatocellular carcinoma
- 5 May 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 43 (8) , 1295-1302
Heart volume on health checkup CT scans inversely correlates with pulse rate: data-driven analysis using deep-learning segmentation
Purpose This study aims to elucidate correlation between heart volume on computed tomography (CT) and various health checkup examination data in the general population. Furthermore, this study aims to examine the utility of a deep-learning segmentation tool in the data-driven analysis of CT big data. Materials and methods Health checkup examination data and CT images acquired in 2013 and 2018 were retrospectively analyzed. We first quantified heart volume using a public deep-learning model, TotalSegmentator. The accuracy of segmentation was evaluated using Dice score on 30 randomly chosen images and annotation by a radiologist. Then, Spearman’s partial correlation was calculated for 58 numerical items, and the analysis of covariance was performed for 13 categorical items, adjusting for the effect of gender, medication, height, weight, abdominal circumference, and age. The variables found to be significant proceeded to longitudinal analysis. Results In the dataset, 7993 records were eligible for cross-sectional analysis and 1306 individuals were eligible for longitudinal analysis. Pulse rate was most strongly inversely correlated with the heart volume (Spearman’s correlation coefficients ranging from – 0.29 to – 0.33). A 10 bpm increase in pulse rate was correlated with roughly a 0.5 percentage point decrease in the cardiothoracic ratio. Hemoglobin, hematocrit, total protein, albumin, and cholinesterase also showed weak inverse correlation. Five-year longitudinal analysis corroborated these findings. Conclusions We found that pulse rate was the strongest covariate of the heart volume on CT, rather than other cardiovascular-related variables such as blood pressure. The study also demonstrated the feasibility and utility of the artificial intelligence-assisted data-driven research on CT big data.
- 5 May 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 43 (8) , 1295-1302
Heart volume on health checkup CT scans inversely correlates with pulse rate: data-driven analysis using deep-learning segmentation
Purpose This study aims to elucidate correlation between heart volume on computed tomography (CT) and various health checkup examination data in the general population. Furthermore, this study aims to examine the utility of a deep-learning segmentation tool in the data-driven analysis of CT big data. Materials and methods Health checkup examination data and CT images acquired in 2013 and 2018 were retrospectively analyzed. We first quantified heart volume using a public deep-learning model, TotalSegmentator. The accuracy of segmentation was evaluated using Dice score on 30 randomly chosen images and annotation by a radiologist. Then, Spearman’s partial correlation was calculated for 58 numerical items, and the analysis of covariance was performed for 13 categorical items, adjusting for the effect of gender, medication, height, weight, abdominal circumference, and age. The variables found to be significant proceeded to longitudinal analysis. Results In the dataset, 7993 records were eligible for cross-sectional analysis and 1306 individuals were eligible for longitudinal analysis. Pulse rate was most strongly inversely correlated with the heart volume (Spearman’s correlation coefficients ranging from – 0.29 to – 0.33). A 10 bpm increase in pulse rate was correlated with roughly a 0.5 percentage point decrease in the cardiothoracic ratio. Hemoglobin, hematocrit, total protein, albumin, and cholinesterase also showed weak inverse correlation. Five-year longitudinal analysis corroborated these findings. Conclusions We found that pulse rate was the strongest covariate of the heart volume on CT, rather than other cardiovascular-related variables such as blood pressure. The study also demonstrated the feasibility and utility of the artificial intelligence-assisted data-driven research on CT big data.
- 17 April 2025
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (11) , 5079-5089
DWI of the rectum with deep learning reconstruction: comparison of PROPELLER, reduced FOV, and conventional DWI.
Purpose To compare the image quality and diagnostic performance of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER), reduced field-of-view (rFOV), and conventional diffusion-weighted imaging (cDWI) combined with deep learning reconstruction (DLR) for evaluating rectal tumors. Methods This prospective study included 42 MRI examinations of 38 patients with rectal tumors who underwent initial staging and/or restaging MRI. PROPELLER-DWI, rFOV-DWI, and cDWI obtained with DLR were reviewed by two radiologists and compared for image quality and diagnostic performance for local tumor extent at staging and restaging and response to chemoradiotherapy at restaging. Results PROPELLER-DWI had significantly the least artifacts and distortions, but the worst perceptive noise, while rFOV-DWI had significantly the best sharpness for both readers (P < 0.01). For overall image quality and rectal/tumor conspicuity, PROPELLER-DWI and rFOV-DWI were significantly superior to cDWI in both readers (P < 0.01). The incidence of suboptimal image quality was significantly lower with PROPELLER-DWI and rFOV-DWI than with cDWI (5 and 1 patients with PROPELLER-DWI, 14 and 6 with rFOV-DWI, and 29 and 25 with cDWI by the 2 readers, P < 0.01). Although there were no significant differences in the accuracy of staging and restaging among the 3 types of DWI, inter-reader agreement was highest for PROPELLER-DWI (weighted kappa, 0.62–0.71) compared with cDWI (weighted kappa, 0.38–0.52) and rFOV-DWI (weighted kappa, 0.47–0.61). Conclusions PROPELLER-DWI and rFOV-DWI with DLR may improve the image quality of rectal DWI by reducing artifacts and distortions or increasing sharpness, although the impact on diagnostic accuracy was not significant. Graphical abstract
- 17 April 2025
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (11) , 5079-5089
DWI of the rectum with deep learning reconstruction: comparison of PROPELLER, reduced FOV, and conventional DWI.
Purpose To compare the image quality and diagnostic performance of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER), reduced field-of-view (rFOV), and conventional diffusion-weighted imaging (cDWI) combined with deep learning reconstruction (DLR) for evaluating rectal tumors. Methods This prospective study included 42 MRI examinations of 38 patients with rectal tumors who underwent initial staging and/or restaging MRI. PROPELLER-DWI, rFOV-DWI, and cDWI obtained with DLR were reviewed by two radiologists and compared for image quality and diagnostic performance for local tumor extent at staging and restaging and response to chemoradiotherapy at restaging. Results PROPELLER-DWI had significantly the least artifacts and distortions, but the worst perceptive noise, while rFOV-DWI had significantly the best sharpness for both readers (P < 0.01). For overall image quality and rectal/tumor conspicuity, PROPELLER-DWI and rFOV-DWI were significantly superior to cDWI in both readers (P < 0.01). The incidence of suboptimal image quality was significantly lower with PROPELLER-DWI and rFOV-DWI than with cDWI (5 and 1 patients with PROPELLER-DWI, 14 and 6 with rFOV-DWI, and 29 and 25 with cDWI by the 2 readers, P < 0.01). Although there were no significant differences in the accuracy of staging and restaging among the 3 types of DWI, inter-reader agreement was highest for PROPELLER-DWI (weighted kappa, 0.62–0.71) compared with cDWI (weighted kappa, 0.38–0.52) and rFOV-DWI (weighted kappa, 0.47–0.61). Conclusions PROPELLER-DWI and rFOV-DWI with DLR may improve the image quality of rectal DWI by reducing artifacts and distortions or increasing sharpness, although the impact on diagnostic accuracy was not significant. Graphical abstract
- Open Access
- 19 February 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1) , 1-13
Three-dimensional amide proton transfer (APT) imaging appliable to navigation surgery can present comparable metabolic activity of glioblastoma to 11C-Methionine PET
Background: Amide proton transfer (APT) imaging has been proposed as a technique to assess tumor metabolic activity. We have previously 11C-methionine positron emission tomography (11C-Met-PET) can evaluate the metabolic activity of peritumoral area including infiltrating tumor cells in glioblastoma (GBM). To resolve disadvantages of 11C-Met-PET, in the present study, we aimed to evaluate whether three-dimensional fast spin echo-based APT (3D FSE-APT) imaging is usable for not only presenting the metabolic activity of brain tumors, but also detecting areas where infiltrating tumor cells including glioma stem cells (GSCs) could exist, by applying an image-guided navigation system incorporating 3D FSE-APT to glioblastoma surgery. Methods: Twenty-six consecutive patients with GBMs were enrolled in this study. Among these 26 cases, 10 patients underwent 11C-Met-PET examination. All 26 patients underwent two-dimensional single shot fast spine echo-based APT acquisition with a chemical exchange saturation transfer sequence (2D SSFSE-APT). The most recent 14 cases underwent 3D FSE-APT to examine whether 3D APT imaging was applicable to the navigation system. We investigated the clinical applicability of 3D FSE-APT by comparison with 2D SSFSE-APT and evaluated the utility of 3D FSE-APT as a metabolic imaging guide in the intraoperative navigation system. We also analyzed whether 3D FSE-APT can depict the extent of infiltrating tumor cells including GSCs in the peritumoral area in GBM. Results: The most recent 14 cases underwent 3D FSE-APT. The 3D FSE-APT was visually almost equivalent to 2D SSFSE-APT and mean APT intensity (APTmean) in GBM obtained by 3D FSE-APT was almost equal to that from 2D SSFSE-APT. Mean APTmean on 2D SSFSE-APT at the site showing a tumor-to-contralateral normal brain tissue ratio (TNR) of 1.4 on 11C-Met-PET was 1.52 ± 0.16%. In contrast, mean APTmean on 3D FSE-APT at the same site was 1.30 ± 0.06%. The optimal cut-off value for APTmean on 3D FSE-APT was evaluated as 1.28%, offering 100% sensitivity and 100% specificity. Incorporating 3D FSE-APT into the navigation system allowed tumor resection including infiltrating tumor cells under image-guided navigation. Mean Ki-67 staining index in the area with a mean APTmean of 1.28% was 11.8% (range, 5.0–20.0%). Conclusions: The area of tumor invasion could be evaluated by 3D FSE-APT in a similar way to 11C-Met-PET, and the cut-off value for deciding the borderline between the area including infiltrating tumor cells and that with almost no tumor cells was 12.8%. In addition, 3D FSE-APT could be applied to navigation systems and may have great potential as an imaging modality replacing 11C-Met-PET in GBM surgery.
- 19 February 2025
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 167 (1) , 1-13
Open AccessThree-dimensional amide proton transfer (APT) imaging appliable to navigation surgery can present comparable metabolic activity of glioblastoma to 11C-Methionine PET
Background: Amide proton transfer (APT) imaging has been proposed as a technique to assess tumor metabolic activity. We have previously 11C-methionine positron emission tomography (11C-Met-PET) can evaluate the metabolic activity of peritumoral area including infiltrating tumor cells in glioblastoma (GBM). To resolve disadvantages of 11C-Met-PET, in the present study, we aimed to evaluate whether three-dimensional fast spin echo-based APT (3D FSE-APT) imaging is usable for not only presenting the metabolic activity of brain tumors, but also detecting areas where infiltrating tumor cells including glioma stem cells (GSCs) could exist, by applying an image-guided navigation system incorporating 3D FSE-APT to glioblastoma surgery. Methods: Twenty-six consecutive patients with GBMs were enrolled in this study. Among these 26 cases, 10 patients underwent 11C-Met-PET examination. All 26 patients underwent two-dimensional single shot fast spine echo-based APT acquisition with a chemical exchange saturation transfer sequence (2D SSFSE-APT). The most recent 14 cases underwent 3D FSE-APT to examine whether 3D APT imaging was applicable to the navigation system. We investigated the clinical applicability of 3D FSE-APT by comparison with 2D SSFSE-APT and evaluated the utility of 3D FSE-APT as a metabolic imaging guide in the intraoperative navigation system. We also analyzed whether 3D FSE-APT can depict the extent of infiltrating tumor cells including GSCs in the peritumoral area in GBM. Results: The most recent 14 cases underwent 3D FSE-APT. The 3D FSE-APT was visually almost equivalent to 2D SSFSE-APT and mean APT intensity (APTmean) in GBM obtained by 3D FSE-APT was almost equal to that from 2D SSFSE-APT. Mean APTmean on 2D SSFSE-APT at the site showing a tumor-to-contralateral normal brain tissue ratio (TNR) of 1.4 on 11C-Met-PET was 1.52 ± 0.16%. In contrast, mean APTmean on 3D FSE-APT at the same site was 1.30 ± 0.06%. The optimal cut-off value for APTmean on 3D FSE-APT was evaluated as 1.28%, offering 100% sensitivity and 100% specificity. Incorporating 3D FSE-APT into the navigation system allowed tumor resection including infiltrating tumor cells under image-guided navigation. Mean Ki-67 staining index in the area with a mean APTmean of 1.28% was 11.8% (range, 5.0–20.0%). Conclusions: The area of tumor invasion could be evaluated by 3D FSE-APT in a similar way to 11C-Met-PET, and the cut-off value for deciding the borderline between the area including infiltrating tumor cells and that with almost no tumor cells was 12.8%. In addition, 3D FSE-APT could be applied to navigation systems and may have great potential as an imaging modality replacing 11C-Met-PET in GBM surgery.
- Open Access
- 1 November 2024
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 43 (6) , 457-468
Washout-parametric imaging with Sonazoid for enhanced differentiation of focal liver lesions
Purpose: The study aimed to compare the diagnostic performance of washout-parametric imaging (WOPI) with that of conventional contrast-enhanced ultrasound (cCEUS) in differentiating focal liver lesions (FLLs).Methods: A total of 181 FLLs were imaged with contrast-enhanced ultrasound using Sonazoid, and the recordings were captured for 10 minutes in a prospective setting. WOPI was constructed from three images, depicting the arterial phase (peak enhancement), the early portal venous phase (1-minute post-injection), and the vasculo-Kupffer phase (5 or 10 minutes post-injection). The intensity variations in these images were color-coded and superimposed to produce a single image representing the washout timing across the lesions. From the 181 FLLs, 30 hepatocellular carcinomas (HCCs), 30 non-HCC malignancies, and 30 benign lesions were randomly selected for an observer study. Both techniques (cCEUS and WOPI) were evaluated by four off-site readers. They classified each lesion as benign or malignant using a continuous rating scale, with the endpoints representing "definitely benign" and "definitely malignant." The diagnostic performance of cCEUS and WOPI was compared using the area under the receiver operating characteristic curve (AUC) with the DeLong test. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC).Results: The difference in average AUC values between WOPI and cCEUS was 0.0062 (95% confidence interval, -0.0161 to 0.0285), indicating no significant difference between techniques. The interobserver agreement was higher for WOPI (ICC, 0.77) than cCEUS (ICC, 0.67).Conclusion: The diagnostic performance of WOPI is comparable to that of cCEUS in differentiating FLLs, with superior interobserver agreement.
- 1 November 2024
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 43 (6) , 457-468
Open AccessWashout-parametric imaging with Sonazoid for enhanced differentiation of focal liver lesions
Purpose: The study aimed to compare the diagnostic performance of washout-parametric imaging (WOPI) with that of conventional contrast-enhanced ultrasound (cCEUS) in differentiating focal liver lesions (FLLs).Methods: A total of 181 FLLs were imaged with contrast-enhanced ultrasound using Sonazoid, and the recordings were captured for 10 minutes in a prospective setting. WOPI was constructed from three images, depicting the arterial phase (peak enhancement), the early portal venous phase (1-minute post-injection), and the vasculo-Kupffer phase (5 or 10 minutes post-injection). The intensity variations in these images were color-coded and superimposed to produce a single image representing the washout timing across the lesions. From the 181 FLLs, 30 hepatocellular carcinomas (HCCs), 30 non-HCC malignancies, and 30 benign lesions were randomly selected for an observer study. Both techniques (cCEUS and WOPI) were evaluated by four off-site readers. They classified each lesion as benign or malignant using a continuous rating scale, with the endpoints representing "definitely benign" and "definitely malignant." The diagnostic performance of cCEUS and WOPI was compared using the area under the receiver operating characteristic curve (AUC) with the DeLong test. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC).Results: The difference in average AUC values between WOPI and cCEUS was 0.0062 (95% confidence interval, -0.0161 to 0.0285), indicating no significant difference between techniques. The interobserver agreement was higher for WOPI (ICC, 0.77) than cCEUS (ICC, 0.67).Conclusion: The diagnostic performance of WOPI is comparable to that of cCEUS in differentiating FLLs, with superior interobserver agreement.
- Open Access
- 5 July 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (7) , e0301919
Verification of the effect of data-driven brain motion correction on PET imaging
Introduction: Brain positron emission tomography/computed tomography (PET/CT) scans are useful for identifying the cause of dementia by evaluating glucose metabolism in the brain with F-18-fluorodeoxyglucose or Aβ deposition with F-18-florbetaben. However, since imaging time ranges from 10 to 30 minutes, movements during the examination might result in image artifacts, which interfere with diagnosis. To solve this problem, data-driven brain motion correction (DDBMC) techniques are capable of performing motion corrected reconstruction using highly accurate motion estimates with high temporal resolution. In this study, we investigated the effectiveness of DDBMC techniques on PET/CT images using a Hoffman phantom, involving continuous rotational and tilting motion, each expanded up to approximately 20 degrees. Materials and methods: Listmode imaging was performed using a Hoffman phantom that reproduced rotational and tilting motions of the head. Brain motion correction processing was performed on the obtained data. Reconstructed images with and without brain motion correction processing were compared. Visual evaluations by a nuclear medicine specialist and quantitative parameters of images with correction and reference still images were compared. Results: Normalized Mean Squared Error (NMSE) results demonstrated the effectiveness of DDBMC in compensating for rotational and tilting motions during PET imaging. In Cases 1 and 2 involving rotational motion, NMSE decreased from 0.15–0.2 to approximately 0.01 with DDBMC, indicating a substantial reduction in differences from the reference image across various brain regions. In the Structural Similarity Index (SSIM), DDBMC improved it to above 0.96 Contrast assessment revealed notable improvements with DDBMC. In continuous rotational motion, % contrast increased from 42.4% to 73.5%, In tilting motion, % contrast increased from 52.3% to 64.5%, eliminating significant differences from the static reference image. These findings underscore the efficacy of DDBMC in enhancing image contrast and minimizing motion induced variations across different motion scenarios. Conclusions: DDBMC processing can effectively compensate for continuous rotational and tilting motion of the head during PET, with motion angles of approximately 20 degrees. However, a significant limitation of this study is the exclusive validation of the proposed method using a Hoffman phantom; its applicability to the human brain has not been investigated. Further research involving human subjects is necessary to assess the generalizability and reliability of the presented motion correction technique in real clinical scenarios.
- 5 July 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (7) , e0301919
Open AccessVerification of the effect of data-driven brain motion correction on PET imaging
Introduction: Brain positron emission tomography/computed tomography (PET/CT) scans are useful for identifying the cause of dementia by evaluating glucose metabolism in the brain with F-18-fluorodeoxyglucose or Aβ deposition with F-18-florbetaben. However, since imaging time ranges from 10 to 30 minutes, movements during the examination might result in image artifacts, which interfere with diagnosis. To solve this problem, data-driven brain motion correction (DDBMC) techniques are capable of performing motion corrected reconstruction using highly accurate motion estimates with high temporal resolution. In this study, we investigated the effectiveness of DDBMC techniques on PET/CT images using a Hoffman phantom, involving continuous rotational and tilting motion, each expanded up to approximately 20 degrees. Materials and methods: Listmode imaging was performed using a Hoffman phantom that reproduced rotational and tilting motions of the head. Brain motion correction processing was performed on the obtained data. Reconstructed images with and without brain motion correction processing were compared. Visual evaluations by a nuclear medicine specialist and quantitative parameters of images with correction and reference still images were compared. Results: Normalized Mean Squared Error (NMSE) results demonstrated the effectiveness of DDBMC in compensating for rotational and tilting motions during PET imaging. In Cases 1 and 2 involving rotational motion, NMSE decreased from 0.15–0.2 to approximately 0.01 with DDBMC, indicating a substantial reduction in differences from the reference image across various brain regions. In the Structural Similarity Index (SSIM), DDBMC improved it to above 0.96 Contrast assessment revealed notable improvements with DDBMC. In continuous rotational motion, % contrast increased from 42.4% to 73.5%, In tilting motion, % contrast increased from 52.3% to 64.5%, eliminating significant differences from the static reference image. These findings underscore the efficacy of DDBMC in enhancing image contrast and minimizing motion induced variations across different motion scenarios. Conclusions: DDBMC processing can effectively compensate for continuous rotational and tilting motion of the head during PET, with motion angles of approximately 20 degrees. However, a significant limitation of this study is the exclusive validation of the proposed method using a Hoffman phantom; its applicability to the human brain has not been investigated. Further research involving human subjects is necessary to assess the generalizability and reliability of the presented motion correction technique in real clinical scenarios.
- 19 February 2024
- Published by Springer Nature in Neuroradiology
- Vol. 66 (6) , 937-945
Usefulness of pituitary high-resolution 3D MRI with deep-learning-based reconstruction for perioperative evaluation of pituitary adenomas
Purpose To evaluate the diagnostic value of T1-weighted 3D fast spin-echo sequence (CUBE) with deep learning-based reconstruction (DLR) for depiction of pituitary adenoma and parasellar regions on contrast-enhanced MRI. Methods We evaluated 24 patients with pituitary adenoma or residual tumor using CUBE with and without DLR, 1-mm slice thickness 2D T1WI (1-mm 2D T1WI) with DLR, and 3D spoiled gradient echo sequence (SPGR) as contrast-enhanced MRI. Depiction scores of pituitary adenoma and parasellar regions were assigned by two neuroradiologists, and contrast-to-noise ratio (CNR) was calculated. Results CUBE with DLR showed significantly higher scores for depicting pituitary adenoma or residual tumor compared to CUBE without DLR, 1-mm 2D T1WI with DLR, and SPGR (p < 0.01). The depiction score for delineation of the boundary between adenoma and the cavernous sinus was higher for CUBE with DLR than for 1-mm 2D T1WI with DLR (p = 0.01), but the difference was not significant when compared to SPGR (p = 0.20). CUBE with DLR had better interobserver agreement for evaluating adenomas than 1-mm 2D T1WI with DLR (Kappa values, 0.75 vs. 0.41). The CNR of the adenoma to the brain parenchyma increased to a ratio of 3.6 (obtained by dividing 13.7, CNR of CUBE with DLR, by 3.8, that without DLR, p < 0.01). CUBE with DLR had a significantly higher CNR than SPGR, but not 1-mm 2D T1WI with DLR. Conclusion On the contrast-enhanced MRI, compared to CUBE without DLR, 1-mm 2D T1WI with DLR and SPGR, CUBE with DLR improves the depiction of pituitary adenoma and parasellar regions.
- 19 February 2024
- Published by Springer Nature in Neuroradiology
- Vol. 66 (6) , 937-945
Usefulness of pituitary high-resolution 3D MRI with deep-learning-based reconstruction for perioperative evaluation of pituitary adenomas
Purpose To evaluate the diagnostic value of T1-weighted 3D fast spin-echo sequence (CUBE) with deep learning-based reconstruction (DLR) for depiction of pituitary adenoma and parasellar regions on contrast-enhanced MRI. Methods We evaluated 24 patients with pituitary adenoma or residual tumor using CUBE with and without DLR, 1-mm slice thickness 2D T1WI (1-mm 2D T1WI) with DLR, and 3D spoiled gradient echo sequence (SPGR) as contrast-enhanced MRI. Depiction scores of pituitary adenoma and parasellar regions were assigned by two neuroradiologists, and contrast-to-noise ratio (CNR) was calculated. Results CUBE with DLR showed significantly higher scores for depicting pituitary adenoma or residual tumor compared to CUBE without DLR, 1-mm 2D T1WI with DLR, and SPGR (p < 0.01). The depiction score for delineation of the boundary between adenoma and the cavernous sinus was higher for CUBE with DLR than for 1-mm 2D T1WI with DLR (p = 0.01), but the difference was not significant when compared to SPGR (p = 0.20). CUBE with DLR had better interobserver agreement for evaluating adenomas than 1-mm 2D T1WI with DLR (Kappa values, 0.75 vs. 0.41). The CNR of the adenoma to the brain parenchyma increased to a ratio of 3.6 (obtained by dividing 13.7, CNR of CUBE with DLR, by 3.8, that without DLR, p < 0.01). CUBE with DLR had a significantly higher CNR than SPGR, but not 1-mm 2D T1WI with DLR. Conclusion On the contrast-enhanced MRI, compared to CUBE without DLR, 1-mm 2D T1WI with DLR and SPGR, CUBE with DLR improves the depiction of pituitary adenoma and parasellar regions.
- Open Access
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A319
Verification of effect of analytical conditions of shear wave velocity on ability to evaluate microstructure
In this study, the relationship between the analytical conditions of shear wave velocity (SWV) and the evaluation ability of microstructure were verified by FDTD simulation. By adding acoustic radiation force (ARF) to the left edge of the simulation space, which mimicked various fatty livers with different fat mass, shear waves propagating in the lateral direction were simulated in each liver. SWV was calculated using the time difference calculated by the cross-correlation method from two timewaves laterally located in the simulation. By varying the resolution of the SWV evaluation, the effect of scattering and refraction of shear waves in fat droplets, etc. on the macroscopic shear propagation was evaluated. Although shear waves could be evaluated stably when tracking shear waves at the spatial step (time width) of the clinical device level, the effects of individual fatty substances were strongly indicated when tracking in the microscopic sense of 10 μm (50 ns). When there was a thick fat layer or a sparse muscle layer near the body surface, the irradiation of ARFI did not work as expected and the evaluation accuracy of SWV decreased.
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A319
Open AccessVerification of effect of analytical conditions of shear wave velocity on ability to evaluate microstructure
In this study, the relationship between the analytical conditions of shear wave velocity (SWV) and the evaluation ability of microstructure were verified by FDTD simulation. By adding acoustic radiation force (ARF) to the left edge of the simulation space, which mimicked various fatty livers with different fat mass, shear waves propagating in the lateral direction were simulated in each liver. SWV was calculated using the time difference calculated by the cross-correlation method from two timewaves laterally located in the simulation. By varying the resolution of the SWV evaluation, the effect of scattering and refraction of shear waves in fat droplets, etc. on the macroscopic shear propagation was evaluated. Although shear waves could be evaluated stably when tracking shear waves at the spatial step (time width) of the clinical device level, the effects of individual fatty substances were strongly indicated when tracking in the microscopic sense of 10 μm (50 ns). When there was a thick fat layer or a sparse muscle layer near the body surface, the irradiation of ARFI did not work as expected and the evaluation accuracy of SWV decreased.