Scientific Research Institute of Technical Physics and Automation
Type
FacilityLocations
Moscow, RussiaLatest Publications
- Open Access
Micro-Arc Coatings with Different Types of Microparticles on Titanium Alloy: Formation, Structure, and Properties
This study examines the effects of electrolyte composition, specifically the incorporation of dispersed particles, on the properties and formation kinetics of micro-arc oxidation (MAO) coatings on a bioinert titanium alloy. Coatings with particles of β-tricalcium phosphate (CP), wollastonite (CS), and combined coatings containing both types of particles (SP) were obtained. The MAO process was carried out using a Micro-Arc 3.0 unit in pulsed potentiostatic anode mode, with the process voltage ranging from 350 to 500 volts. The surface morphology and internal structure of the coatings were examined using scanning electron microscopy. The elemental composition of the coatings was determined by the EDX method, while the phase composition and fine structure of the coatings were investigated by XRD and TEM methods, respectively. The adhesion properties of the coatings were determined by means of scratch testing. When the MAO process voltage was increased to 500 V, the thickness of CP, CS, and SP coatings increased to 80, 50, and 50 μm, respectively. Notably, SP coatings demonstrated the highest adhesion strength (critical load Lc = 22 N), indicating their potential for use in load-bearing medical implants, where preventing delamination under mechanical stress is critical.
Open AccessMicro-Arc Coatings with Different Types of Microparticles on Titanium Alloy: Formation, Structure, and Properties
This study examines the effects of electrolyte composition, specifically the incorporation of dispersed particles, on the properties and formation kinetics of micro-arc oxidation (MAO) coatings on a bioinert titanium alloy. Coatings with particles of β-tricalcium phosphate (CP), wollastonite (CS), and combined coatings containing both types of particles (SP) were obtained. The MAO process was carried out using a Micro-Arc 3.0 unit in pulsed potentiostatic anode mode, with the process voltage ranging from 350 to 500 volts. The surface morphology and internal structure of the coatings were examined using scanning electron microscopy. The elemental composition of the coatings was determined by the EDX method, while the phase composition and fine structure of the coatings were investigated by XRD and TEM methods, respectively. The adhesion properties of the coatings were determined by means of scratch testing. When the MAO process voltage was increased to 500 V, the thickness of CP, CS, and SP coatings increased to 80, 50, and 50 μm, respectively. Notably, SP coatings demonstrated the highest adhesion strength (critical load Lc = 22 N), indicating their potential for use in load-bearing medical implants, where preventing delamination under mechanical stress is critical.
- 1 October 2024
- Published by Allerton Press in Moscow University Physics Bulletin
- Vol. 79 (5) , 656-664
Development of an Electron Linac for Radiation Therapy. II. Reduction of Accelerating Field Strength, Improvement of Accelerating Structure Efficiency
The second part of the article on the development of an electron linac for the radiation therapy complex ‘‘Onyx’’ is devoted to sol
- 1 October 2024
- Published by Allerton Press in Moscow University Physics Bulletin
- Vol. 79 (5) , 656-664
Development of an Electron Linac for Radiation Therapy. II. Reduction of Accelerating Field Strength, Improvement of Accelerating Structure Efficiency
The second part of the article on the development of an electron linac for the radiation therapy complex ‘‘Onyx’’ is devoted to sol
- 4 July 2024
- Published by The Russian Academy of Sciences in Вестник Российской академии наук
- Vol. 94 (1) , 80-86
External-beam neutron therapy: the first domestic medical unit
Modern radiotherapy, employing traditional linear accelerators, has nearly reached its apex in terms of efficacy in treating oncological diseases. The challenge before researchers in the field of implementing cutting-edge technologies pertains to the utilization of fundamentally different therapeutic approaches, one of which is remote neutron therapy. Its salient advantages include an increased relative biological effectiveness of radiation, while the complexities of implementing specific technological solutions encompass forming a beam of the required geometry and spectral characteristics. The article delineates the key milestones in the development of the usage of fast neutron beams for remote radiotherapy, a general description of the neutron therapy complex and its primary structural components is also presented. These are currently being developed as an innovative, mass-producible medical project.
- 4 July 2024
- Published by The Russian Academy of Sciences in Вестник Российской академии наук
- Vol. 94 (1) , 80-86
External-beam neutron therapy: the first domestic medical unit
Modern radiotherapy, employing traditional linear accelerators, has nearly reached its apex in terms of efficacy in treating oncological diseases. The challenge before researchers in the field of implementing cutting-edge technologies pertains to the utilization of fundamentally different therapeutic approaches, one of which is remote neutron therapy. Its salient advantages include an increased relative biological effectiveness of radiation, while the complexities of implementing specific technological solutions encompass forming a beam of the required geometry and spectral characteristics. The article delineates the key milestones in the development of the usage of fast neutron beams for remote radiotherapy, a general description of the neutron therapy complex and its primary structural components is also presented. These are currently being developed as an innovative, mass-producible medical project.
- 8 August 2023
- Published by Pleiades Publishing Ltd in Physics of Particles and Nuclei Letters
- Vol. 20 (4) , 880-883
Evaluation the Possibilities of Determining Au, U, Nd, Gd, W Elements on Electron Linear Accelerator LUE-8
During geological exploration and development of gold deposits there is a need to determine the mass content of precious metals in ordinary and technological samples. The Research Institute of Technical Physics and Automation (hereinafter referred to as NIITFA) has developed the “Aura”-type complex for gamma-activation analysis of gold content in ore samples. The article considers the possibility of determining rare-earth elements in ore composition for the accelerator energy range up to 8 MeV.
- 8 August 2023
- Published by Pleiades Publishing Ltd in Physics of Particles and Nuclei Letters
- Vol. 20 (4) , 880-883
Evaluation the Possibilities of Determining Au, U, Nd, Gd, W Elements on Electron Linear Accelerator LUE-8
During geological exploration and development of gold deposits there is a need to determine the mass content of precious metals in ordinary and technological samples. The Research Institute of Technical Physics and Automation (hereinafter referred to as NIITFA) has developed the “Aura”-type complex for gamma-activation analysis of gold content in ore samples. The article considers the possibility of determining rare-earth elements in ore composition for the accelerator energy range up to 8 MeV.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2760 (1) , 020006
Target material selection for new O-ring gantry linac
O-ring gantry linac for radiation therapy is being developed in JSC NIITFA. One of the key elements that define the linac’s efficiency is the target that produc
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2760 (1) , 020006
Open AccessTarget material selection for new O-ring gantry linac
O-ring gantry linac for radiation therapy is being developed in JSC NIITFA. One of the key elements that define the linac’s efficiency is the target that produc
- 1 August 2022
- Published by Pleiades Publishing Ltd in Biophysics
- Vol. 67 (4) , 642-646
Antitumor Efficacy of the Combined Use of Gold Polyacrylate (Aurumacryl) and Radiation Therapy in an Experiment
The ability of gold polyacrylate (aurumacryl) to increase the sensitivity of murine tumor (В-16/F10 melanoma) to radiation treatment has been explored. Radiation therapy employed in combination with aurumacryl leads to a moderate but significant inhibition of tumor growth by 81–90%, compared to control, on day 32 after tumor grafting. The specific tumor growth rate decreases by a factor of 2.5 after the combined treatment and by 1.9 after radiation therapy alone. Combined treatment and radiation therapy alone extend the lifespan in mice with tumors almost equally, by 42 and 46%, respectively, compared to the control.
- 1 August 2022
- Published by Pleiades Publishing Ltd in Biophysics
- Vol. 67 (4) , 642-646
Antitumor Efficacy of the Combined Use of Gold Polyacrylate (Aurumacryl) and Radiation Therapy in an Experiment
The ability of gold polyacrylate (aurumacryl) to increase the sensitivity of murine tumor (В-16/F10 melanoma) to radiation treatment has been explored. Radiation therapy employed in combination with aurumacryl leads to a moderate but significant inhibition of tumor growth by 81–90%, compared to control, on day 32 after tumor grafting. The specific tumor growth rate decreases by a factor of 2.5 after the combined treatment and by 1.9 after radiation therapy alone. Combined treatment and radiation therapy alone extend the lifespan in mice with tumors almost equally, by 42 and 46%, respectively, compared to the control.
- 1 April 2021
- Published by Springer Nature in Measurement Techniques
- Vol. 64 (1) , 60-63
Calculation of the Radiation Dose Absorbed by Human Biological Tissue When Using Imaging Equipment in Radiotherapy
- 1 April 2021
- Published by Springer Nature in Measurement Techniques
- Vol. 64 (1) , 60-63
Calculation of the Radiation Dose Absorbed by Human Biological Tissue When Using Imaging Equipment in Radiotherapy
- 1 January 2021
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 1
Calculation of the radiation dose absorbed by human biological tissue when using imaging equipment in radiоtherapy
Considered the issues of X-ray dose control during diagnostic and therapeutic procedures using imaging tools. The dose of X-ray radiation from the visualization devices absorbed by the biological tissue of a person was determined when monitoring the position of the patient on the therapeutic table of the electron accelerator before the radiation therapy session. The processes of transmission of photons and electrons through the medium were simulated, and the X-ray spectra were measured. The emission spectrum of the Varian G-242 Rotating Anode X-ray Tube was obtained using an XR-100-CdTe spectrometer. The absorbed dose is calculated by the Monte Carlo method. The absorbed dose in the water phantom at tube voltage up to 80 kV was 0,9–1,5 mGy.
- 1 January 2021
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 1
Calculation of the radiation dose absorbed by human biological tissue when using imaging equipment in radiоtherapy
Considered the issues of X-ray dose control during diagnostic and therapeutic procedures using imaging tools. The dose of X-ray radiation from the visualization devices absorbed by the biological tissue of a person was determined when monitoring the position of the patient on the therapeutic table of the electron accelerator before the radiation therapy session. The processes of transmission of photons and electrons through the medium were simulated, and the X-ray spectra were measured. The emission spectrum of the Varian G-242 Rotating Anode X-ray Tube was obtained using an XR-100-CdTe spectrometer. The absorbed dose is calculated by the Monte Carlo method. The absorbed dose in the water phantom at tube voltage up to 80 kV was 0,9–1,5 mGy.
- 10 September 2020
- Published by Springer Nature in Biomedical Engineering
- Vol. 54 (3) , 179-183
Investigation of the Lag Effect in X-Ray Flat-Panel Detector for Cone-Beam Computed Tomography
- 10 September 2020
- Published by Springer Nature in Biomedical Engineering
- Vol. 54 (3) , 179-183
Investigation of the Lag Effect in X-Ray Flat-Panel Detector for Cone-Beam Computed Tomography
- 1 July 2020
- Published by Pleiades Publishing Ltd in Biophysics
- Vol. 65 (4) , 541-547
The Change in the Linear Energy Transfer of a Clinical Proton Beam in the Presence of Gold Nanoparticles
Gold nanoparticles are promising radiosensitizers for proton radiotherapy. However, the physical mechanisms of gold nanoparticles radiosensitization remain unclear. In the present study, the Geant4 toolkit was used to estimate by the Monte-Carlo simulation the changes (1) in the contribution of primary and secondary particles to the absorbed dose, (2) in the dose-averaged linear energy transfer, and (3) in the relative biological effectiveness of a 150 MeV proton beam caused by the addition of 50 mg/mL of gold nanoparticles to the irradiated water phantom. In the presence of gold nanoparticles no significant changes in the absorbed dose and the Bragg peak position were found, at the same time a redistribution of the contribution of secondary particles to the absorbed dose was recorded. An increase in the contributions from protons (~16%), recoil nuclei (~58%), α-particles (~400%), deuterons (~900%), tritons (~3000%), and photons (~7000%) was observed ~10 mm beyond the Bragg peak. The contribution of the secondary electrons decreased by ~35%. This redistribution led to ~5-fold increase in the dose-averaged linear energy transfer at the distal edge of the Bragg curve; this, in turn, may cause the ~1.4−2.2-fold increase in the relative biological effectiveness within this region. Thus, it is critically important to take into account the presence of gold nanoparticles when dosimetric planning proton radiotherapy in order to avoid unwanted damage to the normal tissues around the tumor.
- 1 July 2020
- Published by Pleiades Publishing Ltd in Biophysics
- Vol. 65 (4) , 541-547
The Change in the Linear Energy Transfer of a Clinical Proton Beam in the Presence of Gold Nanoparticles
Gold nanoparticles are promising radiosensitizers for proton radiotherapy. However, the physical mechanisms of gold nanoparticles radiosensitization remain unclear. In the present study, the Geant4 toolkit was used to estimate by the Monte-Carlo simulation the changes (1) in the contribution of primary and secondary particles to the absorbed dose, (2) in the dose-averaged linear energy transfer, and (3) in the relative biological effectiveness of a 150 MeV proton beam caused by the addition of 50 mg/mL of gold nanoparticles to the irradiated water phantom. In the presence of gold nanoparticles no significant changes in the absorbed dose and the Bragg peak position were found, at the same time a redistribution of the contribution of secondary particles to the absorbed dose was recorded. An increase in the contributions from protons (~16%), recoil nuclei (~58%), α-particles (~400%), deuterons (~900%), tritons (~3000%), and photons (~7000%) was observed ~10 mm beyond the Bragg peak. The contribution of the secondary electrons decreased by ~35%. This redistribution led to ~5-fold increase in the dose-averaged linear energy transfer at the distal edge of the Bragg curve; this, in turn, may cause the ~1.4−2.2-fold increase in the relative biological effectiveness within this region. Thus, it is critically important to take into account the presence of gold nanoparticles when dosimetric planning proton radiotherapy in order to avoid unwanted damage to the normal tissues around the tumor.