Nexen (Canada)

Type
CompanyLocations
Calgary, CanadaLatest Publications
- 8 November 2016
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 30 (12) , 10228-10235
Mechanistic Understanding of the Effect of Temperature and Salinity on the Water/Toluene Interfacial Tension
- 8 November 2016
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 30 (12) , 10228-10235
Mechanistic Understanding of the Effect of Temperature and Salinity on the Water/Toluene Interfacial Tension
- 29 September 2014
- Published by ASME International
External Pipeline Leak Detection Based on Fiber Optic Sensing for the Kinosis 12″–16″ and 16″–20″ Pipe-in-Pipe System
The concern of the pipeline industry and general population for a safe and green environment is higher than ever. This highlights the need for efficient leak detection to prevent environmental catastrophes and operational disruption. Therefore, accurate techniques to detect and locate very small leaks that could develop into larger leaks are a valuable asset for the construction of key pipelines. External pipeline leak detection systems based on distributed fiber optic sensing emerge as the most appropriate solution for automatic detection and localization of very small leaks. In the case of the Kinosis pipeline system, two 11km Electrically Heat Traced Pipe-In-Pipe (EHTPIP) pipelines have been built between the Nexen Long lake upgrader and Nexen Kinosis SAGD facilities. The fiber optic sensing cable is directly in contact with the EHTPIP external surface. These pipelines carry Produced Emulsion and Boiler Feed Water at temperatures as high as 120°C and 150°C respectively. The fiber optic distributed sensing system provides temperature feedback information to the operator, not only in operation and in case of a leak but also when the Electrical Heat Trace system is turned on; in this case, the monitoring system can detect and locate overheating problems and/or signs of heating failures. In the case of a leak, the outer temperature of the pipeline will increase; this will automatically be detected and monitored by the DITEST temperature monitoring system and will trigger an alarm to the Nexen LONG LAKE upgrader SCADA system for that specific location. Furthermore, the combination of fiber optic distributed monitoring with the PIP technology enables to detect and locate a leak in the inner pipeline at a very early stage, therefore avoiding any environmental damage (the leak is still contained by the outer PIP tube) and giving time to the pipeline operator to plan a sectional replacement.
- 29 September 2014
- Published by ASME International
External Pipeline Leak Detection Based on Fiber Optic Sensing for the Kinosis 12″–16″ and 16″–20″ Pipe-in-Pipe System
The concern of the pipeline industry and general population for a safe and green environment is higher than ever. This highlights the need for efficient leak detection to prevent environmental catastrophes and operational disruption. Therefore, accurate techniques to detect and locate very small leaks that could develop into larger leaks are a valuable asset for the construction of key pipelines. External pipeline leak detection systems based on distributed fiber optic sensing emerge as the most appropriate solution for automatic detection and localization of very small leaks. In the case of the Kinosis pipeline system, two 11km Electrically Heat Traced Pipe-In-Pipe (EHTPIP) pipelines have been built between the Nexen Long lake upgrader and Nexen Kinosis SAGD facilities. The fiber optic sensing cable is directly in contact with the EHTPIP external surface. These pipelines carry Produced Emulsion and Boiler Feed Water at temperatures as high as 120°C and 150°C respectively. The fiber optic distributed sensing system provides temperature feedback information to the operator, not only in operation and in case of a leak but also when the Electrical Heat Trace system is turned on; in this case, the monitoring system can detect and locate overheating problems and/or signs of heating failures. In the case of a leak, the outer temperature of the pipeline will increase; this will automatically be detected and monitored by the DITEST temperature monitoring system and will trigger an alarm to the Nexen LONG LAKE upgrader SCADA system for that specific location. Furthermore, the combination of fiber optic distributed monitoring with the PIP technology enables to detect and locate a leak in the inner pipeline at a very early stage, therefore avoiding any environmental damage (the leak is still contained by the outer PIP tube) and giving time to the pipeline operator to plan a sectional replacement.
- 1 January 2013
- Published by American Association of Petroleum Geologists AAPG/Datapages
- p. 565-604
Reservoir Modeling by Constraining Stochastic Simulation to Deterministically Interpreted Three-dimensional Geobodies
Tidally influenced meandering river deposits of the Cretaceous middle McMurray Formation are characterized by rapid vertical and lateral lithological and associated reservoir property changes. Within the reservoir, water may occur below, above, and in the middle of the bitumen column, and there may be multiple gas intervals. Although conceptual understanding about the depositional environment and its control on distribution of different fluids (bitumen, water, and gas) is documented in literature, integration of these concepts into reservoir models and history matching through flow simulation is lacking. Thus, even in areas with closely spaced wells (as much as several hundred meters apart), geostatistical modeling approaches show high degrees of randomness. This chapter closes the gap between the conceptual mapping and numerical modeling approaches. Specifically, the workflow for creating a deterministic three-dimensional (3-D), object-based (geobody) model, which integrates data from closely spaced wells, high-quality 3-D seismic data, and sound geologic concepts is shown. The geobodies are typically large-scale depositional elements comprising meandering river deposits. Geobodies include channel lag breccia (tens to hundreds of meters wide and as much as several meters thick), lower and upper point-bar deposits (from several hundreds of meters to as much as 5 km [3 mi] wide and as much as 40m [131 ft] thick), and mud plug deposits (as much as 500m [1640 ft] wide and as much as 40m [131 ft] thick). Because of the potential impact on reservoir development economics, top water, top gas, and low-bitumen, high-water saturated zones are mapped as distinct geobodies. Based on their reservoir development potential, geobodies can then be classified as reservoir flow unit types 1 and 2, reservoir flow barriers, and reservoir flow impairments.
- 1 January 2013
- Published by American Association of Petroleum Geologists AAPG/Datapages
- p. 565-604
Reservoir Modeling by Constraining Stochastic Simulation to Deterministically Interpreted Three-dimensional Geobodies
Tidally influenced meandering river deposits of the Cretaceous middle McMurray Formation are characterized by rapid vertical and lateral lithological and associated reservoir property changes. Within the reservoir, water may occur below, above, and in the middle of the bitumen column, and there may be multiple gas intervals. Although conceptual understanding about the depositional environment and its control on distribution of different fluids (bitumen, water, and gas) is documented in literature, integration of these concepts into reservoir models and history matching through flow simulation is lacking. Thus, even in areas with closely spaced wells (as much as several hundred meters apart), geostatistical modeling approaches show high degrees of randomness. This chapter closes the gap between the conceptual mapping and numerical modeling approaches. Specifically, the workflow for creating a deterministic three-dimensional (3-D), object-based (geobody) model, which integrates data from closely spaced wells, high-quality 3-D seismic data, and sound geologic concepts is shown. The geobodies are typically large-scale depositional elements comprising meandering river deposits. Geobodies include channel lag breccia (tens to hundreds of meters wide and as much as several meters thick), lower and upper point-bar deposits (from several hundreds of meters to as much as 5 km [3 mi] wide and as much as 40m [131 ft] thick), and mud plug deposits (as much as 500m [1640 ft] wide and as much as 40m [131 ft] thick). Because of the potential impact on reservoir development economics, top water, top gas, and low-bitumen, high-water saturated zones are mapped as distinct geobodies. Based on their reservoir development potential, geobodies can then be classified as reservoir flow unit types 1 and 2, reservoir flow barriers, and reservoir flow impairments.
- 1 January 2013
- Published by American Association of Petroleum Geologists AAPG/Datapages
- p. 1-21
Heavy Oil and Bitumen Petroleum Systems in Alberta and Beyond
Global bitumen and heavy-oil resources are estimated to be 5.6 trillion bbl, with most of that occurring in the western hemisphere. In the past decade, significant advances in the development and production of these resources have occurred by way of the critical integration of geology, geophysics, engineering, modeling economics, and transportation. Bitumen and heavy-oil deposits are mainly unconsolidated sands bound together by biodegraded bitumen. In the case of the world's largest oil-sand and heavy-oil deposit, located in western Canada, the oil sands occur in deposits of low sedimentary accommodation on the distal side of a foreland basin. Hydrocarbons were derived from Mississippian Exshaw and/or Mesozoic source rocks. The hydrocarbons accumulated in tidally influenced fluvioestuarine sediments, midchannel bars, brackish bays, bay-hed deltas, and tidal flats. Elsewhere, in another major global heavy-oil resource, the Oficina Formation in Venezuela was similarly deposited in fluvioestuarine to deltaic settings. Current in-situ oil-sand development focuses on steam-assisted gravity drainage (SAGD) technology and, to a lesser degree, cyclic steam stimulation (CSS). Other emerging technologies being piloted include in-situ combustion, electrothermal dynamic stripping, and passive heating-assisted recovery methods.
- 1 January 2013
- Published by American Association of Petroleum Geologists AAPG/Datapages
- p. 1-21
Heavy Oil and Bitumen Petroleum Systems in Alberta and Beyond
Global bitumen and heavy-oil resources are estimated to be 5.6 trillion bbl, with most of that occurring in the western hemisphere. In the past decade, significant advances in the development and production of these resources have occurred by way of the critical integration of geology, geophysics, engineering, modeling economics, and transportation. Bitumen and heavy-oil deposits are mainly unconsolidated sands bound together by biodegraded bitumen. In the case of the world's largest oil-sand and heavy-oil deposit, located in western Canada, the oil sands occur in deposits of low sedimentary accommodation on the distal side of a foreland basin. Hydrocarbons were derived from Mississippian Exshaw and/or Mesozoic source rocks. The hydrocarbons accumulated in tidally influenced fluvioestuarine sediments, midchannel bars, brackish bays, bay-hed deltas, and tidal flats. Elsewhere, in another major global heavy-oil resource, the Oficina Formation in Venezuela was similarly deposited in fluvioestuarine to deltaic settings. Current in-situ oil-sand development focuses on steam-assisted gravity drainage (SAGD) technology and, to a lesser degree, cyclic steam stimulation (CSS). Other emerging technologies being piloted include in-situ combustion, electrothermal dynamic stripping, and passive heating-assisted recovery methods.
- 17 September 2012
- Published by Society of Exploration Geophysicists
- Vol. 1, 1-4
Application of Geophysics to Unconventional Reservoirs
Development of unconventional reservoirs requires the characterization of more aspects than conventional reservoirs. Geophysical methods can assist in all areas of assessment. As development proceeds, reservoir interval properties, structural elements, geomechanical stratigraphy, natural fracture networks and hydraulic fracture networks will all need detailed description to assist in the optimization process. Local water sources and disposal zones will also need to be identified, evaluated and characterized.
- 17 September 2012
- Published by Society of Exploration Geophysicists
- Vol. 1, 1-4
Application of Geophysics to Unconventional Reservoirs
Development of unconventional reservoirs requires the characterization of more aspects than conventional reservoirs. Geophysical methods can assist in all areas of assessment. As development proceeds, reservoir interval properties, structural elements, geomechanical stratigraphy, natural fracture networks and hydraulic fracture networks will all need detailed description to assist in the optimization process. Local water sources and disposal zones will also need to be identified, evaluated and characterized.
- 1 December 2011
- Published by Canadian Society of Petroleum Geologists in Bulletin of Canadian Petroleum Geology
- Vol. 59 (4) , 295-316
Bitumen and heavy oil geochemistry: a tool for distinguishing barriers from baffles in oil sands reservoirs
To optimize SAGD well-pair placement and improve thermal recovery operations, geochemical bitumen composition logs are used to identify barriers and baffles to fluid flow, which may compartmentalize McMurray Formation reservoirs in the Athabasca Oil Sands. SAGD steam chamber growth and cumulative steam oil ratios are sensitive to both vertical permeability and bitumen viscosity variations, which are commonly encountered in the oil sands reservoirs. In the McMurray Formation, tidally influenced meandering channel deposits are commonly vertically stacked, forming reservoir columns up to 80 m thick. In many instances, inclined heterolithic strata (IHS), consisting of interbedded sand and silt deposited on point bars, comprise barriers to vertical steam chamber growth at multiple horizons of a reservoir. Thus, the identification, characterization, and delineation of IHS intervals is a critical step for evaluating the reservoir development potential, and designing an optimal reservoir development strategy. While siltstone beds are routinely identified in cores and geophysical logs, thin siltstone beds that can act as a barrier to fluid flow are not discernible in seismic reflection data and have proven difficult to correlate between adjacent delineation wells. In this study, geochemical bitumen analysis is used to determine the integrity and continuity of siltstone beds within IHS in order to assess their potential impact on SAGD steam chamber growth. First, high-resolution molecular composition profiles are obtained from gas chromatography – mass spectrometry analyses of bitumen extracted from cores. The continuity of biodegradation-susceptible aromatic hydrocarbon concentrations measured through vertical profiles of a reservoir were used to determine if siltstone-prone intervals observed in log and core data acted as barriers or baffles to fluid flow over geological time. Integration of the bitumen molecular composition data with geological cross-sections fosters predictions of the lateral extent of the identified barriers. Furthermore, inferences about reservoir charging and in-reservoir fluid mixing histories are also made. Geochemical log data indicate that thickness of a heterogeneous low permeability interval is not necessarily the critical attribute of a barrier to fluid flow. Integration of both sedimentological information and bitumen geochemical data is useful for the identification of barriers and baffles to fluid flow in oil sand reservoirs. The method can be applied prior to positioning of SAGD well-pairs and thus could represent an important step for development planning of heterogeneous reservoirs.
- 1 December 2011
- Published by Canadian Society of Petroleum Geologists in Bulletin of Canadian Petroleum Geology
- Vol. 59 (4) , 295-316
Bitumen and heavy oil geochemistry: a tool for distinguishing barriers from baffles in oil sands reservoirs
To optimize SAGD well-pair placement and improve thermal recovery operations, geochemical bitumen composition logs are used to identify barriers and baffles to fluid flow, which may compartmentalize McMurray Formation reservoirs in the Athabasca Oil Sands. SAGD steam chamber growth and cumulative steam oil ratios are sensitive to both vertical permeability and bitumen viscosity variations, which are commonly encountered in the oil sands reservoirs. In the McMurray Formation, tidally influenced meandering channel deposits are commonly vertically stacked, forming reservoir columns up to 80 m thick. In many instances, inclined heterolithic strata (IHS), consisting of interbedded sand and silt deposited on point bars, comprise barriers to vertical steam chamber growth at multiple horizons of a reservoir. Thus, the identification, characterization, and delineation of IHS intervals is a critical step for evaluating the reservoir development potential, and designing an optimal reservoir development strategy. While siltstone beds are routinely identified in cores and geophysical logs, thin siltstone beds that can act as a barrier to fluid flow are not discernible in seismic reflection data and have proven difficult to correlate between adjacent delineation wells. In this study, geochemical bitumen analysis is used to determine the integrity and continuity of siltstone beds within IHS in order to assess their potential impact on SAGD steam chamber growth. First, high-resolution molecular composition profiles are obtained from gas chromatography – mass spectrometry analyses of bitumen extracted from cores. The continuity of biodegradation-susceptible aromatic hydrocarbon concentrations measured through vertical profiles of a reservoir were used to determine if siltstone-prone intervals observed in log and core data acted as barriers or baffles to fluid flow over geological time. Integration of the bitumen molecular composition data with geological cross-sections fosters predictions of the lateral extent of the identified barriers. Furthermore, inferences about reservoir charging and in-reservoir fluid mixing histories are also made. Geochemical log data indicate that thickness of a heterogeneous low permeability interval is not necessarily the critical attribute of a barrier to fluid flow. Integration of both sedimentological information and bitumen geochemical data is useful for the identification of barriers and baffles to fluid flow in oil sand reservoirs. The method can be applied prior to positioning of SAGD well-pairs and thus could represent an important step for development planning of heterogeneous reservoirs.
- 1 December 2009
- Published by Canadian Society of Petroleum Geologists in Bulletin of Canadian Petroleum Geology
- Vol. 57 (4) , 409-429
Delineation of a sandstone-filled incised valley in the Lower Cretaceous Dina-Cummings interval: implications for development of the Winter Pool, west-central Saskatchewan
Major heavy oil deposits are present in Lower Cretaceous strata of west-central Saskatchewan. The Winter Heavy Oil Pool (approximately 566 044 mmbl) consists of bitumen-rich sands from the Aptian–Albian Dina and Cummings members of the Mannville Group. This succession unconformably overlies Paleozoic carbonates and is conformably overlain by the Lloydminster Member. Lower Cretaceous deposition in the Winter area was influenced by topography on the regional sub-Cretaceous unconformity, including the Unity uplands south of the study area and major paleovalleys opening to the northwest. The overall depositional framework consists of a lowstand and transgressive fluvial sandstone deposit (Dina Member) that evolved into a brackish embayment system (Cummings Member). Upon sea level fall, a valley was incised into the mudstone-dominated marginal marine deposits, which filled with sandstone during a subsequent sea-level rise (Cummings Member). Exploitable heavy oil reservoirs are contained within these incised valley sandstone beds. Further transgression led to a rising water table with widespread deposition of an organic-rich shale and coal followed by marine shale of the Lloydminster Member. The new depositional model for the area should lead to more optimal placement of horizontal wells in the reservoir, which is vital to continued bitumen extraction from the Winter Pool.
- 1 December 2009
- Published by Canadian Society of Petroleum Geologists in Bulletin of Canadian Petroleum Geology
- Vol. 57 (4) , 409-429
Delineation of a sandstone-filled incised valley in the Lower Cretaceous Dina-Cummings interval: implications for development of the Winter Pool, west-central Saskatchewan
Major heavy oil deposits are present in Lower Cretaceous strata of west-central Saskatchewan. The Winter Heavy Oil Pool (approximately 566 044 mmbl) consists of bitumen-rich sands from the Aptian–Albian Dina and Cummings members of the Mannville Group. This succession unconformably overlies Paleozoic carbonates and is conformably overlain by the Lloydminster Member. Lower Cretaceous deposition in the Winter area was influenced by topography on the regional sub-Cretaceous unconformity, including the Unity uplands south of the study area and major paleovalleys opening to the northwest. The overall depositional framework consists of a lowstand and transgressive fluvial sandstone deposit (Dina Member) that evolved into a brackish embayment system (Cummings Member). Upon sea level fall, a valley was incised into the mudstone-dominated marginal marine deposits, which filled with sandstone during a subsequent sea-level rise (Cummings Member). Exploitable heavy oil reservoirs are contained within these incised valley sandstone beds. Further transgression led to a rising water table with widespread deposition of an organic-rich shale and coal followed by marine shale of the Lloydminster Member. The new depositional model for the area should lead to more optimal placement of horizontal wells in the reservoir, which is vital to continued bitumen extraction from the Winter Pool.
- 15 September 2009
- Published by Wiley in Sedimentology
- Vol. 56 (6) , 1655-1669
Counter point bar deposits: lithofacies and reservoir significance in the meandering modern Peace River and ancient McMurray Formation, Alberta, Canada
Counter point bar deposits in the meandering Peace River, North‐central Alberta, Wood Buffalo National Park, are distinct from point bar deposits in terms of morphology, lithofacies and reservoir potential for fluids. Previously referred to as the distal‐most parts of point bars, point bar tails and concave bank‐bench deposits, counter point bar deposits have concave morphological scroll patterns rather than convex as with point bars. The Peace is a large river (bankfull discharge 11 700 m3 sec−1, width 375 to 700 m, depth 15 m, gradient 0·00004 or 4 cm km−1) in which counter point bar deposits are dominated by silt (80% to 90%), which contrasts with sand‐dominant (90% to 100%) point bar deposits. Beginning at the meander inflection (transition from convex to concave), counter point bar deposit stratigraphy thickens as a wedge‐like architecture in the distal direction until the deposit is nearly as thick as the point bar deposits. The low permeability silt‐dominant lithofacies in counter point bar deposits will limit reservoir extent and movement of fluids in both modern and ancient subsurface fluvial deposits. In the exploration and extraction of bitumen and heavy oil in subsurface fluvial rocks, identification and mapping of reservoir potential of point bar deposits and counter point bar deposits is now possible in the fluvial‐dominated tidal estuarine Lower Cretaceous Middle McMurray Formation, North‐east Alberta. Recent geophysical advances have facilitated imaging of some ancient buried point bar deposits and counter point bar deposits which, on the basis of morphological shape of sedimentary bodies observed from seismic amplitude, can be interpreted and mapped as depositional elements or blocks that contain associated sandstone or siltstone dominant lithofacies, respectively. As counter point bar deposits exhibit poor permeability and thus limit reservoir potential for water, natural gas, light crude, heavy oil and bitumen, counter point bar deposits should be avoided in resource developments. Geophysical imaging, interpretation and mapping of point bar deposit and counter point bar deposit elements provide new opportunities to improve recovery of bitumen and heavy oil and reduce development costs in subsurface cyclic steam stimulation and steam‐assisted gravity drainage projects by not drilling into counter point bar deposits.
- 15 September 2009
- Published by Wiley in Sedimentology
- Vol. 56 (6) , 1655-1669
Counter point bar deposits: lithofacies and reservoir significance in the meandering modern Peace River and ancient McMurray Formation, Alberta, Canada
Counter point bar deposits in the meandering Peace River, North‐central Alberta, Wood Buffalo National Park, are distinct from point bar deposits in terms of morphology, lithofacies and reservoir potential for fluids. Previously referred to as the distal‐most parts of point bars, point bar tails and concave bank‐bench deposits, counter point bar deposits have concave morphological scroll patterns rather than convex as with point bars. The Peace is a large river (bankfull discharge 11 700 m3 sec−1, width 375 to 700 m, depth 15 m, gradient 0·00004 or 4 cm km−1) in which counter point bar deposits are dominated by silt (80% to 90%), which contrasts with sand‐dominant (90% to 100%) point bar deposits. Beginning at the meander inflection (transition from convex to concave), counter point bar deposit stratigraphy thickens as a wedge‐like architecture in the distal direction until the deposit is nearly as thick as the point bar deposits. The low permeability silt‐dominant lithofacies in counter point bar deposits will limit reservoir extent and movement of fluids in both modern and ancient subsurface fluvial deposits. In the exploration and extraction of bitumen and heavy oil in subsurface fluvial rocks, identification and mapping of reservoir potential of point bar deposits and counter point bar deposits is now possible in the fluvial‐dominated tidal estuarine Lower Cretaceous Middle McMurray Formation, North‐east Alberta. Recent geophysical advances have facilitated imaging of some ancient buried point bar deposits and counter point bar deposits which, on the basis of morphological shape of sedimentary bodies observed from seismic amplitude, can be interpreted and mapped as depositional elements or blocks that contain associated sandstone or siltstone dominant lithofacies, respectively. As counter point bar deposits exhibit poor permeability and thus limit reservoir potential for water, natural gas, light crude, heavy oil and bitumen, counter point bar deposits should be avoided in resource developments. Geophysical imaging, interpretation and mapping of point bar deposit and counter point bar deposit elements provide new opportunities to improve recovery of bitumen and heavy oil and reduce development costs in subsurface cyclic steam stimulation and steam‐assisted gravity drainage projects by not drilling into counter point bar deposits.
- 1 August 2009
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 178 (2) , 1004-1020
Structure and development of the southeast Newfoundland continental passive margin: derived from SCREECH Transect 3
- 1 August 2009
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 178 (2) , 1004-1020
Structure and development of the southeast Newfoundland continental passive margin: derived from SCREECH Transect 3
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 00903507,p. 1-9
Oil field harmonic concerns resulting from high impedance sources, multiple power converters and long cables
The paper presents an effective, robust and economical design solution for a severe power system harmonic problem. The case study examines an isolated power system at an oil field central processing facility supplied by on-site generators. Elevated harmonic distortion originates from the electronic adjustable speed drives installed on the well site submersible pump motors. The original design uses phase shifting techniques that achieve a significant reduction in harmonic current. Unexpectedly, even though harmonic current remained moderate, harmonic voltage distortion became excessive as the system grew in size. This unusual condition arose from a combination of high source impedance and distributed stray capacitances from long power cables that created many partial resonances throughout the system. Voltage distortion contributed to extensive equipment failures and system upsets over the years. The implemented solution is expected to provide considerable long-term improvement in the power system operation and availability.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 00903507,p. 1-9
Oil field harmonic concerns resulting from high impedance sources, multiple power converters and long cables
The paper presents an effective, robust and economical design solution for a severe power system harmonic problem. The case study examines an isolated power system at an oil field central processing facility supplied by on-site generators. Elevated harmonic distortion originates from the electronic adjustable speed drives installed on the well site submersible pump motors. The original design uses phase shifting techniques that achieve a significant reduction in harmonic current. Unexpectedly, even though harmonic current remained moderate, harmonic voltage distortion became excessive as the system grew in size. This unusual condition arose from a combination of high source impedance and distributed stray capacitances from long power cables that created many partial resonances throughout the system. Voltage distortion contributed to extensive equipment failures and system upsets over the years. The implemented solution is expected to provide considerable long-term improvement in the power system operation and availability.