Impulse Dynamics (United States)
Types
Company, FunderLocations
Orangeburg, United StatesLatest Publications
- 26 July 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
The Forgotten History of Semi‐Implanted Radiofrequency‐ and Inductive‐Powered Cardiac Pacing Systems
Radiofrequency‐powered and inductively coupled semi‐implanted pacemakers offered an early alternative to battery‐powered implantable pulse generators by transferring energy across intact skin to a small, implanted receiver. This review summarizes key clinical and engineering developments from the first reported radiofrequency‐powered pacing in 1959 through subsequent refinements and commercial implementations, including the Cutler‐Hammer and Cordis Transicor RF systems, and it places these efforts alongside the Abrams/Lightwood inductively coupled device commercialized by Joseph Lucas Ltd. These systems reduced implanted size and allowed external servicing, but they imposed major human factors and safety constraints because pacing depended on correct placement and continuous operation of external hardware. As implantable‐grade batteries, hermetic packaging, and lead technology improved, fully implantable pacemakers became clinically dominant. The historical experience nonetheless established durable principles of transcutaneous energy transfer that continue to inform modern externally powered implantable therapies where brief interruptions are clinically tolerable.
- 26 July 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
The Forgotten History of Semi‐Implanted Radiofrequency‐ and Inductive‐Powered Cardiac Pacing Systems
Radiofrequency‐powered and inductively coupled semi‐implanted pacemakers offered an early alternative to battery‐powered implantable pulse generators by transferring energy across intact skin to a small, implanted receiver. This review summarizes key clinical and engineering developments from the first reported radiofrequency‐powered pacing in 1959 through subsequent refinements and commercial implementations, including the Cutler‐Hammer and Cordis Transicor RF systems, and it places these efforts alongside the Abrams/Lightwood inductively coupled device commercialized by Joseph Lucas Ltd. These systems reduced implanted size and allowed external servicing, but they imposed major human factors and safety constraints because pacing depended on correct placement and continuous operation of external hardware. As implantable‐grade batteries, hermetic packaging, and lead technology improved, fully implantable pacemakers became clinically dominant. The historical experience nonetheless established durable principles of transcutaneous energy transfer that continue to inform modern externally powered implantable therapies where brief interruptions are clinically tolerable.
- 7 March 2026
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 32 (10) , 1833-1837
Cardiac Contractility Modulation for Patients With Heart Failure and Preserved Ejection Fraction: The AIM HIGHer Study
- 7 March 2026
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 32 (10) , 1833-1837
Cardiac Contractility Modulation for Patients With Heart Failure and Preserved Ejection Fraction: The AIM HIGHer Study
- 19 January 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (4) , 371-387
Pioneering Rhythm Management: A Design Analysis of the Earliest Battery‐Powered Implantable Pacemakers
In 1958 and 1960, Dr. Rune Elmqvist (Sweden) and Wilson Greatbatch (USA) independently developed the first battery‐powered implantable cardiac pacemakers. Though unaware of each other's work, both pioneers employed a transistorized blocking oscillator as the core of their pacemaker design, enabled by the recent availability of silicon transistors. This paper analyzes the convergent design principles of these early devices, comparing circuit architectures, power sources, and clinical considerations. Elmqvist's use of rechargeable nickel–cadmium batteries with transcutaneous charging contrasted with Greatbatch's strategy of primary mercury–zinc cells, each reflecting distinct engineering priorities. To better understand these designs, we constructed characterization breadboards, as well as reconstructed functional, visually faithful replicas of three historical devices: Elmqvist's 1958 prototype, Elema–Schönander 1959's model EM135, and the 1960 Greatbatch–Chardack pacemaker. Our engineering analysis and replica testing demonstrate the elegant simplicity of these pioneering systems, offering insights into the early intersection of electronics and implantable medical therapy.
- 19 January 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (4) , 371-387
Pioneering Rhythm Management: A Design Analysis of the Earliest Battery‐Powered Implantable Pacemakers
In 1958 and 1960, Dr. Rune Elmqvist (Sweden) and Wilson Greatbatch (USA) independently developed the first battery‐powered implantable cardiac pacemakers. Though unaware of each other's work, both pioneers employed a transistorized blocking oscillator as the core of their pacemaker design, enabled by the recent availability of silicon transistors. This paper analyzes the convergent design principles of these early devices, comparing circuit architectures, power sources, and clinical considerations. Elmqvist's use of rechargeable nickel–cadmium batteries with transcutaneous charging contrasted with Greatbatch's strategy of primary mercury–zinc cells, each reflecting distinct engineering priorities. To better understand these designs, we constructed characterization breadboards, as well as reconstructed functional, visually faithful replicas of three historical devices: Elmqvist's 1958 prototype, Elema–Schönander 1959's model EM135, and the 1960 Greatbatch–Chardack pacemaker. Our engineering analysis and replica testing demonstrate the elegant simplicity of these pioneering systems, offering insights into the early intersection of electronics and implantable medical therapy.
- Open Access
- 11 August 2022
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 24 (12) , 2275-2284
Cardiac contractility modulation therapy improves health status in patients with heart failure with preserved ejection fraction: a pilot study ( CCM‐HFpEF )
Aims: This pilot study aimed to assess the potential benefits of cardiac contractility modulation (CCM) in patients with heart failure with preserved ejection fraction (HFpEF). Methods and results: This was a prospective, multicentre, single‐arm, pilot study of CCM therapy in patients with HFpEF and New York Heart Association (NYHA) class II or III. Echocardiographic parameters were measured by an echo core laboratory to determine study eligibility. After CCM device implantation, patients were followed for 24 weeks. Overall, 47 patients (mean age 74.3 ± 4.4 years, 70.2% female) were enrolled, with left ventricular ejection fraction of 59 ± 4.4%, 63.8% with hypertension, 46.8% with atrial fibrillation, 40.4% with diabetes, 31.9% with at least one heart failure hospitalization in the prior year, 61.7% in NYHA class III, and Kansas City Cardiomyopathy Questionnaire (KCCQ) overall summary score of 48.9 ± 21.7. The primary efficacy endpoint (mean change in the KCCQ overall summary score) improved by 18.0 ± 16.6 points ( p < 0.001) and there was an event‐free rate of 93.6% for the primary safety endpoint (device‐ and procedure‐related complications), as adjudicated by an independent physician committee. Conclusion: This pilot study demonstrates that the benefits of CCM may extend to the HFpEF patient population. The significant improvement in health status observed, with no obvious impact on safety, suggests that utilization of CCM for patients with HFpEF could prove to be promising.
- 11 August 2022
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 24 (12) , 2275-2284
Open AccessCardiac contractility modulation therapy improves health status in patients with heart failure with preserved ejection fraction: a pilot study ( CCM‐HFpEF )
Aims: This pilot study aimed to assess the potential benefits of cardiac contractility modulation (CCM) in patients with heart failure with preserved ejection fraction (HFpEF). Methods and results: This was a prospective, multicentre, single‐arm, pilot study of CCM therapy in patients with HFpEF and New York Heart Association (NYHA) class II or III. Echocardiographic parameters were measured by an echo core laboratory to determine study eligibility. After CCM device implantation, patients were followed for 24 weeks. Overall, 47 patients (mean age 74.3 ± 4.4 years, 70.2% female) were enrolled, with left ventricular ejection fraction of 59 ± 4.4%, 63.8% with hypertension, 46.8% with atrial fibrillation, 40.4% with diabetes, 31.9% with at least one heart failure hospitalization in the prior year, 61.7% in NYHA class III, and Kansas City Cardiomyopathy Questionnaire (KCCQ) overall summary score of 48.9 ± 21.7. The primary efficacy endpoint (mean change in the KCCQ overall summary score) improved by 18.0 ± 16.6 points ( p < 0.001) and there was an event‐free rate of 93.6% for the primary safety endpoint (device‐ and procedure‐related complications), as adjudicated by an independent physician committee. Conclusion: This pilot study demonstrates that the benefits of CCM may extend to the HFpEF patient population. The significant improvement in health status observed, with no obvious impact on safety, suggests that utilization of CCM for patients with HFpEF could prove to be promising.
- Open Access
- 8 December 2020
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 18 (1) , 15-21
Cardiac contractility modulation for the treatment of moderate to severe HF
Introduction: Heart failure (HF) affects over 6 million Americans and approximately 650,000 new cases are diagnosed annually, with patients evenly split between HFrEF and HFpEF. Recent advances in therapy for these patients have been limited to pharmaceutical agents, with CRT remaining the most reliable device therapy option since its advent almost twenty years ago. In 2019, after almost two decades without the introduction of a new device therapy for the treatment of moderate HF, the FDA approved CCM® therapy, delivered by the Optimizer Smart device, for patients with NYHA Class III HF who are on guideline-directed medical therapy (GDMT), in normal sinus rhythm (NSR), and with EF ranging from 25% to 45%, and who are ineligible for CRT. Areas covered: Multiple clinical trials support the use of CCM to improve quality of life, functional class, and 6-min hall walk distance. This article will discuss the science behind CCM therapy, the presumed mechanisms of action, the pre-clinical studies that shaped subsequent endeavors, and the clinical trials that support its use. Expert opinion: The introduction of CCM therapy bridges a therapeutic gap for patients with few or no other therapeutic options for NYHA III heart failure.
- 8 December 2020
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 18 (1) , 15-21
Open AccessCardiac contractility modulation for the treatment of moderate to severe HF
Introduction: Heart failure (HF) affects over 6 million Americans and approximately 650,000 new cases are diagnosed annually, with patients evenly split between HFrEF and HFpEF. Recent advances in therapy for these patients have been limited to pharmaceutical agents, with CRT remaining the most reliable device therapy option since its advent almost twenty years ago. In 2019, after almost two decades without the introduction of a new device therapy for the treatment of moderate HF, the FDA approved CCM® therapy, delivered by the Optimizer Smart device, for patients with NYHA Class III HF who are on guideline-directed medical therapy (GDMT), in normal sinus rhythm (NSR), and with EF ranging from 25% to 45%, and who are ineligible for CRT. Areas covered: Multiple clinical trials support the use of CCM to improve quality of life, functional class, and 6-min hall walk distance. This article will discuss the science behind CCM therapy, the presumed mechanisms of action, the pre-clinical studies that shaped subsequent endeavors, and the clinical trials that support its use. Expert opinion: The introduction of CCM therapy bridges a therapeutic gap for patients with few or no other therapeutic options for NYHA III heart failure.
- Open Access
- 1 December 2020
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 7 (6) , 3531-3535
Clinical Effects of Cardiac Contractility Modulation in Heart Failure with Mildly Reduced Systolic Function
Aims Increasing attention is being given to patients with heart failure and ‘mid‐range’ left ventricular ejection fraction (LVEF, ≥40% and P = 0.15). Six‐minute walk distance increased significantly in the CCM group with a net between‐group treatment effect of 53.9 ± 74.2 m (P = 0.05). Peak VO2 improved in the CCM group with a net between‐group treatment effect of 2.0 ± 2.8 mL/kg/min (P = 0.02). Minnesota Living with Heart Failure Questionnaire score decreased from baseline to 24 weeks with a net between‐group treatment effect of −13.1 ± 21.0 (P = 0.10). There were no significant differences in the adverse event rate between the CCM and control groups. Conclusions These preliminary results suggest that CCM exerts favourable effects on exercise tolerance and quality of life in patients with LVEF in the range of 40–45% with an acceptable safety profile. Further randomized controlled studies are planned to prove these effects.
- 1 December 2020
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 7 (6) , 3531-3535
Open AccessClinical Effects of Cardiac Contractility Modulation in Heart Failure with Mildly Reduced Systolic Function
Aims Increasing attention is being given to patients with heart failure and ‘mid‐range’ left ventricular ejection fraction (LVEF, ≥40% and P = 0.15). Six‐minute walk distance increased significantly in the CCM group with a net between‐group treatment effect of 53.9 ± 74.2 m (P = 0.05). Peak VO2 improved in the CCM group with a net between‐group treatment effect of 2.0 ± 2.8 mL/kg/min (P = 0.02). Minnesota Living with Heart Failure Questionnaire score decreased from baseline to 24 weeks with a net between‐group treatment effect of −13.1 ± 21.0 (P = 0.10). There were no significant differences in the adverse event rate between the CCM and control groups. Conclusions These preliminary results suggest that CCM exerts favourable effects on exercise tolerance and quality of life in patients with LVEF in the range of 40–45% with an acceptable safety profile. Further randomized controlled studies are planned to prove these effects.
- Open Access
- 26 February 2016
- Published by VM Media Group sp. z o.o in Cardiology Journal
- Vol. 23 (1) , 114-119
A randomized comparison of 5 versus 12 hours per day of cardiac contractility modulation treatment for heart failure patients: A preliminary report
Cardiac contractility modulation (CCM) signals are non-excitatory electrical signals delivered during the absolute refractory period intended to improve contraction and cardiac function. Clinical trials have shown that CCM treatment significantly improves exercise tolerance and quality of life in symptomatic heart failure patients. Studies with CCM therapy typically include CCM delivery for 3, 5 or 7 h per day, although other configurations are also commonly used. Each has been associated with improved outcomes in heart failure, but it is not clear whether different application durations are associated with the various degrees of benefit. The purpose of the current pilot evaluation study was to evaluate the quality of life, exercise tolerance, and cardiac function, over a 6-month period when CCM was delivered for 5 h/day vs. 12 h/day. Increasing the daily CCM therapy duration is safe and as good as the standard CCM periods of application per day. This single center pilot evaluation study involved 19 medically refractory symptomatic patients with heart failure and reduced left ventricular function who underwent implantation of an Optimizer™ system (Impulse Dynamics, Orangeburg, NY, USA). Patients were randomized into one of two treatment groups; 5 h/day CCM treatment or 12 h/day CCM treatment. Subjects and evaluating physicians were blinded to the study group. Subjects returned to the hospital after 12 and 24 weeks. Efficacy evaluations included changes from baseline to 24 weeks in Minnesota Living With Heart Failure Questionnaire score (MLWHFQ), maximal oxygen consumption in the cardio-pulmonary stress test (peak VO2), New York Heart Association classification (NYHA), 6-min walk distance (6MWD), and ejection fraction (EF). At the end of 24 weeks, clinical improvement was observed in the entire cohort in all efficacy measures (mean change from baseline of -17.1 in MLWHFQ, -0.86 in NYHA, and improvement trend of 1.48 mL O2/kg/min in peak VO2, 31.3 m in 6MWD, and 2.25% in EF). There were no significant differences, either clinically or statistically, between the groups receiving CCM for 5 h/day vs. 12 h/day. Three subjects were voluntarily withdrawn before completing the study. One subject died from pneumonia after 125 days, and 6 serious adverse events were reported, none of which was classified as related to either the device or the procedure. Together with previously reported experience with CCM, delivery of CCM therapy is equally safe and appears similarly effective over the range of shorter (5 h) to longer (12 h) daily periods of application. Given the small sample size, further studies are warranted.
- 26 February 2016
- Published by VM Media Group sp. z o.o in Cardiology Journal
- Vol. 23 (1) , 114-119
Open AccessA randomized comparison of 5 versus 12 hours per day of cardiac contractility modulation treatment for heart failure patients: A preliminary report
Cardiac contractility modulation (CCM) signals are non-excitatory electrical signals delivered during the absolute refractory period intended to improve contraction and cardiac function. Clinical trials have shown that CCM treatment significantly improves exercise tolerance and quality of life in symptomatic heart failure patients. Studies with CCM therapy typically include CCM delivery for 3, 5 or 7 h per day, although other configurations are also commonly used. Each has been associated with improved outcomes in heart failure, but it is not clear whether different application durations are associated with the various degrees of benefit. The purpose of the current pilot evaluation study was to evaluate the quality of life, exercise tolerance, and cardiac function, over a 6-month period when CCM was delivered for 5 h/day vs. 12 h/day. Increasing the daily CCM therapy duration is safe and as good as the standard CCM periods of application per day. This single center pilot evaluation study involved 19 medically refractory symptomatic patients with heart failure and reduced left ventricular function who underwent implantation of an Optimizer™ system (Impulse Dynamics, Orangeburg, NY, USA). Patients were randomized into one of two treatment groups; 5 h/day CCM treatment or 12 h/day CCM treatment. Subjects and evaluating physicians were blinded to the study group. Subjects returned to the hospital after 12 and 24 weeks. Efficacy evaluations included changes from baseline to 24 weeks in Minnesota Living With Heart Failure Questionnaire score (MLWHFQ), maximal oxygen consumption in the cardio-pulmonary stress test (peak VO2), New York Heart Association classification (NYHA), 6-min walk distance (6MWD), and ejection fraction (EF). At the end of 24 weeks, clinical improvement was observed in the entire cohort in all efficacy measures (mean change from baseline of -17.1 in MLWHFQ, -0.86 in NYHA, and improvement trend of 1.48 mL O2/kg/min in peak VO2, 31.3 m in 6MWD, and 2.25% in EF). There were no significant differences, either clinically or statistically, between the groups receiving CCM for 5 h/day vs. 12 h/day. Three subjects were voluntarily withdrawn before completing the study. One subject died from pneumonia after 125 days, and 6 serious adverse events were reported, none of which was classified as related to either the device or the procedure. Together with previously reported experience with CCM, delivery of CCM therapy is equally safe and appears similarly effective over the range of shorter (5 h) to longer (12 h) daily periods of application. Given the small sample size, further studies are warranted.
- Open Access
- 1 April 2015
- Published by Wiley in The FASEB Journal
- Vol. 29 (S1) , 651.6
Cardiac Vagal Afferent Response in Rats during Cardiac Contractility Modulation (CCM)
Congestive heart failure (CHF) is responsible for substantial cardiac morbidity and mortality. Cardiac Contractility Modulation (CCM) delivers non‐excitatory endocardial electrical pulses during the refractory period. CCM enhances cardiac contractility, ejection fraction, and quality of life in patients. The underlying mechanism of action for these benefits is not fully understood. Since similar impulses delivered to the gut increase muscle contraction leading to activation of vagal afferents, we tested the effect of CCM on vagal afferent activity in the heart. Hypothesis: CCM results in an increase in activity of cardiac vagal afferent nerves. Since CCM is non‐excitatory, we speculate that CCM reflexly activates vagal afferents via increases in contractility, reducing excessive efferent sympathetic tone in CHF. Methods: Adult male Sprague‐Dawley rats under pentobarbital anesthesia were instrumented for extracellular recordings of cardiac vagal afferent firing during CCM stimulation of the left ventricle (4V or 7.5V for 60s). Results: In 18 vagal nerve fibers with cardiac receptive fields, CCM produced an intensity dependent increase (p<0.05) in firing frequency of 10 fibers (4.2 ± 1.2 Hz at 7.5V vs. 1.4 ± 0.66 Hz at baseline). 6 neurons were not affected by CCM. In two neurons, 4V stimulation increased while 7.5V had no effect on single fiber firing. Conclusion: CCM, a new therapy for CHF elicits activation of cardiac vagal afferents. This likely results from a reflex increase in regional contractility, contributing to the clinical benefit of CCM via an increase in vagal afferent and reduced sympathetic tone. Supported by Impulse Dynamics, Inc.
- 1 April 2015
- Published by Wiley in The FASEB Journal
- Vol. 29 (S1) , 651.6
Open AccessCardiac Vagal Afferent Response in Rats during Cardiac Contractility Modulation (CCM)
Congestive heart failure (CHF) is responsible for substantial cardiac morbidity and mortality. Cardiac Contractility Modulation (CCM) delivers non‐excitatory endocardial electrical pulses during the refractory period. CCM enhances cardiac contractility, ejection fraction, and quality of life in patients. The underlying mechanism of action for these benefits is not fully understood. Since similar impulses delivered to the gut increase muscle contraction leading to activation of vagal afferents, we tested the effect of CCM on vagal afferent activity in the heart. Hypothesis: CCM results in an increase in activity of cardiac vagal afferent nerves. Since CCM is non‐excitatory, we speculate that CCM reflexly activates vagal afferents via increases in contractility, reducing excessive efferent sympathetic tone in CHF. Methods: Adult male Sprague‐Dawley rats under pentobarbital anesthesia were instrumented for extracellular recordings of cardiac vagal afferent firing during CCM stimulation of the left ventricle (4V or 7.5V for 60s). Results: In 18 vagal nerve fibers with cardiac receptive fields, CCM produced an intensity dependent increase (p<0.05) in firing frequency of 10 fibers (4.2 ± 1.2 Hz at 7.5V vs. 1.4 ± 0.66 Hz at baseline). 6 neurons were not affected by CCM. In two neurons, 4V stimulation increased while 7.5V had no effect on single fiber firing. Conclusion: CCM, a new therapy for CHF elicits activation of cardiac vagal afferents. This likely results from a reflex increase in regional contractility, contributing to the clinical benefit of CCM via an increase in vagal afferent and reduced sympathetic tone. Supported by Impulse Dynamics, Inc.
- 1 March 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 183, 76-81
Efficacy and survival in patients with cardiac contractility modulation: Long-term single center experience in 81 patients
- 1 March 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 183, 76-81
Efficacy and survival in patients with cardiac contractility modulation: Long-term single center experience in 81 patients