Meril Life Sciences (India)
Types
Company, FunderLocations
Mumbai, IndiaLatest Publications
- Open Access
- 11 September 2026
- Published by Marwah Infotech in Asian Pacific Journal of Health Sciences
- Vol. 13 (3) , 149-153
One-Year Safety and Clinical Performance of MERINEUM™ MESH with PROFOUND™ in Hernia Repair: A Multicenter Real-World Study
Background: MERINEUM™ MESH is a sterile, partially absorbable, dual-layer surgical mesh intended for laparoscopic ventral hernia repair and other fascial surgical interventions. This real-world post-market clinical follow-up study evaluated its safety and clinical performance over 12 months. Methods: This retrospective, single-arm, multicenter observational study was conducted across five centers and included patients undergoing hernia repair with MERINEUM™ MESH. The primary endpoint was hernia recurrence at 12 months, defined as the development of a new or recurrent bulge that increased in size with straining. Secondary outcomes included post-operative complications, surgical site infection (SSI), adverse events (AEs), serious AEs (SAEs), and operative time. Patient and procedural data were retrospectively collected from medical records. Results: A total of 141 mesh devices were implanted in 130 patients. The mean age was 54.59 ± 13.53 years, and 71.54% of patients were male. Laparoscopic repair was performed in 92.31% of patients, and the mean operative time was 80.92 ± 24.86 min. No hernia recurrence was observed during the 12-month follow-up, resulting in a 0% recurrence rate. Four patients (3.08%) developed seroma and two (1.54%) developed hematoma; all were managed conservatively and resolved. No SSIs or SAEs were reported. Two perioperative AEs were observed: post-operative abdominal distension managed conservatively and inflammation requiring mesh removal, which subsequently resolved. No additional device-related adverse reactions were reported during follow-up. Conclusion: MERINEUM™ MESH demonstrated a favorable safety and clinical performance profile, characterized by no clinically evident recurrence or SSI and a low incidence of conservatively managed post-operative complications. These findings support its use in hernia repair in the studied population. Larger prospective studies with longer follow-up are warranted to further establish long-term durability and safety.
- 11 September 2026
- Published by Marwah Infotech in Asian Pacific Journal of Health Sciences
- Vol. 13 (3) , 149-153
Open AccessOne-Year Safety and Clinical Performance of MERINEUM™ MESH with PROFOUND™ in Hernia Repair: A Multicenter Real-World Study
Background: MERINEUM™ MESH is a sterile, partially absorbable, dual-layer surgical mesh intended for laparoscopic ventral hernia repair and other fascial surgical interventions. This real-world post-market clinical follow-up study evaluated its safety and clinical performance over 12 months. Methods: This retrospective, single-arm, multicenter observational study was conducted across five centers and included patients undergoing hernia repair with MERINEUM™ MESH. The primary endpoint was hernia recurrence at 12 months, defined as the development of a new or recurrent bulge that increased in size with straining. Secondary outcomes included post-operative complications, surgical site infection (SSI), adverse events (AEs), serious AEs (SAEs), and operative time. Patient and procedural data were retrospectively collected from medical records. Results: A total of 141 mesh devices were implanted in 130 patients. The mean age was 54.59 ± 13.53 years, and 71.54% of patients were male. Laparoscopic repair was performed in 92.31% of patients, and the mean operative time was 80.92 ± 24.86 min. No hernia recurrence was observed during the 12-month follow-up, resulting in a 0% recurrence rate. Four patients (3.08%) developed seroma and two (1.54%) developed hematoma; all were managed conservatively and resolved. No SSIs or SAEs were reported. Two perioperative AEs were observed: post-operative abdominal distension managed conservatively and inflammation requiring mesh removal, which subsequently resolved. No additional device-related adverse reactions were reported during follow-up. Conclusion: MERINEUM™ MESH demonstrated a favorable safety and clinical performance profile, characterized by no clinically evident recurrence or SSI and a low incidence of conservatively managed post-operative complications. These findings support its use in hernia repair in the studied population. Larger prospective studies with longer follow-up are warranted to further establish long-term durability and safety.
- 11 September 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 981
Initial experience with the MIZZO ENDO 4000 robotic surgical system: a prospective, single-center, multi-specialty study
- 11 September 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 981
Initial experience with the MIZZO ENDO 4000 robotic surgical system: a prospective, single-center, multi-specialty study
- 28 July 2026
- Published by BMJ in BMJ Case Reports
- Vol. 19 (7) , e269890
Minimally invasive treatment of optic nerve dural AV fistula: the trans-ophthalmic retrograde approach
Dural arteriovenous fistulas (dAVFs) involving the optic nerve sheath are rare and often present subtly. We report a case of a woman in her 50s with a month-long history of left eye redness, swelling and watering. Examination revealed proptosis and chemosis without vision loss or cranial nerve deficits. MRI showed a dilated superior ophthalmic vein (SOV), initially suggesting a carotico-cavernous fistula. However, digital subtraction angiography confirmed a slow-flow intraorbital dAVF supplied by the left ophthalmic and accessory meningeal arteries, draining via the SOV. Conservative management with carotid compression failed, and after 1 year, worsening symptoms and thrombosed venous outflow precluded standard endovascular access. A direct ultrasound-guided SOV puncture was performed using a micropuncture needle. Embolisation with detachable coils and Menox 18 achieved complete fistula occlusion, with clinical improvement. This case highlights the role of catheter angiography in diagnosing intraorbital dAVFs and demonstrates the feasibility of direct SOV puncture when conventional routes are inaccessible.
- 28 July 2026
- Published by BMJ in BMJ Case Reports
- Vol. 19 (7) , e269890
Minimally invasive treatment of optic nerve dural AV fistula: the trans-ophthalmic retrograde approach
Dural arteriovenous fistulas (dAVFs) involving the optic nerve sheath are rare and often present subtly. We report a case of a woman in her 50s with a month-long history of left eye redness, swelling and watering. Examination revealed proptosis and chemosis without vision loss or cranial nerve deficits. MRI showed a dilated superior ophthalmic vein (SOV), initially suggesting a carotico-cavernous fistula. However, digital subtraction angiography confirmed a slow-flow intraorbital dAVF supplied by the left ophthalmic and accessory meningeal arteries, draining via the SOV. Conservative management with carotid compression failed, and after 1 year, worsening symptoms and thrombosed venous outflow precluded standard endovascular access. A direct ultrasound-guided SOV puncture was performed using a micropuncture needle. Embolisation with detachable coils and Menox 18 achieved complete fistula occlusion, with clinical improvement. This case highlights the role of catheter angiography in diagnosing intraorbital dAVFs and demonstrates the feasibility of direct SOV puncture when conventional routes are inaccessible.
Global variability in bicuspid aortic valve morphology and aortopathy among patients with severe aortic stenosis referred for transcatheter valve implantation
Background While some studies have investigated the characteristics of patients from Asian versus European regions with bicuspid aortic valve (BAV) disease undergoing transcatheter aortic valve implantation (TAVI), geographic differences in a worldwide population remain poorly understood. The aim of our study was to evaluate the geographic differences of aortic valve morphology, annular size and associated aortopathy in a large, diverse population of India, West Europe, East Europe, Latin America, Middle East, Russia Commonwealth of Independent States, Asia Pacific and Africa patients with severe aortic stenosis (AS) referred for TAVI. Methods Data from cardiovascular multislice CT of severe AS patients referred for TAVI were analysed in a centralised core laboratory. Differences in valvular phenotype, annular size and aortic morphology were analysed with a focus on BAV patients. Results Among 12 712 patients evaluated, 3203 (25%) had BAV. These patients were more frequently male, younger and had larger annular area, aortic root diameters and higher prevalence of horizontal aorta (23% vs 10%, pConclusions BAV morphology and annular size showed significant heterogeneity based on the geographical origin. These differences may be relevant for procedural planning and anatomical assessment in BAV patients undergoing TAVI worldwide.
Global variability in bicuspid aortic valve morphology and aortopathy among patients with severe aortic stenosis referred for transcatheter valve implantation
Background While some studies have investigated the characteristics of patients from Asian versus European regions with bicuspid aortic valve (BAV) disease undergoing transcatheter aortic valve implantation (TAVI), geographic differences in a worldwide population remain poorly understood. The aim of our study was to evaluate the geographic differences of aortic valve morphology, annular size and associated aortopathy in a large, diverse population of India, West Europe, East Europe, Latin America, Middle East, Russia Commonwealth of Independent States, Asia Pacific and Africa patients with severe aortic stenosis (AS) referred for TAVI. Methods Data from cardiovascular multislice CT of severe AS patients referred for TAVI were analysed in a centralised core laboratory. Differences in valvular phenotype, annular size and aortic morphology were analysed with a focus on BAV patients. Results Among 12 712 patients evaluated, 3203 (25%) had BAV. These patients were more frequently male, younger and had larger annular area, aortic root diameters and higher prevalence of horizontal aorta (23% vs 10%, pConclusions BAV morphology and annular size showed significant heterogeneity based on the geographical origin. These differences may be relevant for procedural planning and anatomical assessment in BAV patients undergoing TAVI worldwide.
- Open Access
- 25 April 2026
- Published by Elsevier in International Journal of Cardiology
- Vol. 456, 134525
Pacemaker recovery after permanent pacemaker implantation post-transcatheter aortic valve implantation: A sub-study of the LANDMARK trial
- 25 April 2026
- Published by Elsevier in International Journal of Cardiology
- Vol. 456, 134525
Open AccessPacemaker recovery after permanent pacemaker implantation post-transcatheter aortic valve implantation: A sub-study of the LANDMARK trial
- Open Access
- 2 April 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Valvular and Structural Heart Disease
- Vol. 2 (2)
Win ratio analysis for the 1-year composite endpoint: a substudy of the LANDMARK trial
Background: Conventional time-to-first event analyses for composite endpoints consider only the first event, whereas win ratio analyses account for event severity and recurrence. Methods: We performed a win ratio analysis of the 1-year composite endpoint in the LANDMARK trial, a multicentre, non-inferiority study that randomized patients with severe native aortic valve stenosis to receive either the Myval transcatheter heart valve (THV) series (n = 384) or contemporary THVs (n = 384), consisting of the Sapien and Evolut series (n = 192 each). The 1-year composite endpoint included the following components, ranked in hierarchical order: all-cause death, disabling stroke, non-disabling stroke, and procedure- or valve-related hospitalization. For death and stroke events, wins or losses were determined according to the time-to-first-event principle. For procedure- or valve-related hospitalizations, the total number of events was compared. Win ratio analysis was also conducted for an extended composite endpoint that also included quality-of-life outcomes. Results: Among 147 456 (384 × 384) unmatched patient pairs, the win ratio for the primary composite endpoint was 1.02 (95% CI: 0.68–1.51; P = .94), with 17 870 (12.1%) wins for the Myval group and 17 599 (11.9%) for the contemporary group. For the extended composite endpoint, the win ratio was 1.13 (95% CI: 0.82–1.55; P = .45), with 27 007 (18.3%) wins for the Myval group and 23 920 (16.2%) for the contemporary group. Comparisons between the Myval and Sapien groups, and between the Myval and Evolut groups, were also not statistically significant. Conclusions: Win ratio analysis did not demonstrate a significant difference between Myval and contemporary THVs, consistent with the primary time-to-first event analysis of the LANDMARK trial.
- 2 April 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Valvular and Structural Heart Disease
- Vol. 2 (2)
Open AccessWin ratio analysis for the 1-year composite endpoint: a substudy of the LANDMARK trial
Background: Conventional time-to-first event analyses for composite endpoints consider only the first event, whereas win ratio analyses account for event severity and recurrence. Methods: We performed a win ratio analysis of the 1-year composite endpoint in the LANDMARK trial, a multicentre, non-inferiority study that randomized patients with severe native aortic valve stenosis to receive either the Myval transcatheter heart valve (THV) series (n = 384) or contemporary THVs (n = 384), consisting of the Sapien and Evolut series (n = 192 each). The 1-year composite endpoint included the following components, ranked in hierarchical order: all-cause death, disabling stroke, non-disabling stroke, and procedure- or valve-related hospitalization. For death and stroke events, wins or losses were determined according to the time-to-first-event principle. For procedure- or valve-related hospitalizations, the total number of events was compared. Win ratio analysis was also conducted for an extended composite endpoint that also included quality-of-life outcomes. Results: Among 147 456 (384 × 384) unmatched patient pairs, the win ratio for the primary composite endpoint was 1.02 (95% CI: 0.68–1.51; P = .94), with 17 870 (12.1%) wins for the Myval group and 17 599 (11.9%) for the contemporary group. For the extended composite endpoint, the win ratio was 1.13 (95% CI: 0.82–1.55; P = .45), with 27 007 (18.3%) wins for the Myval group and 23 920 (16.2%) for the contemporary group. Comparisons between the Myval and Sapien groups, and between the Myval and Evolut groups, were also not statistically significant. Conclusions: Win ratio analysis did not demonstrate a significant difference between Myval and contemporary THVs, consistent with the primary time-to-first event analysis of the LANDMARK trial.
- Open Access
Coronin1A regulates tumor microenvironment in colitis-associated colorectal cancer in a SUMO-dependent way
Inflammatory bowel disease (IBD), comprising Crohn’s disease and Ulcerative colitis, is a group of multifactorial illnesses with persistent gastrointestinal inflammation and a series of undesirable consequences. IBD patients have a three times higher risk of developing colitis-associated colorectal cancer (CAC). A higher mutational burden due to persistent inflammation acts as a driver of dysplasia and even tumorigenesis. While the pathological sequence is known, the molecular mechanisms underlying the transition from chronic inflammation to CAC remain largely elusive. Post-translational modification- SUMOylation plays an integral role in shaping gut inflammation as well as several forms of cancers, including sporadic colorectal cancer. In this study, the contribution of SUMOylation to CAC pathogenesis was characterized. In the AOM-DSS CAC mice model and human IBD patient specimens, SENP5, but not other deSUMOylases, shows an altered expression. Notably, both SENP5 expression dynamics and alterations in the SUMOylome occur in chronically inflamed and neoplastic colon tissues. SENP5 interactome analysis identified Coronin1A (Coro1A), an actin-binding protein predominantly expressed in immune cells. Coro1A also shows a state-specific, distinct expression pattern in the colon. Interestingly, in contrast to wild-type mice, Coro 1A knockout mice were resistant to polyp formation, with reduced cell proliferation, oncogene expression, and epithelial-to-mesenchymal transition (EMT) gene activation, and reduced extracellular matrix (ECM) development and fibrosis, suggesting its integral role in tumorigenesis. WT mice with chronically inflamed colons and polyps have a higher number of M2-like macrophages, with increased abundance of Coro1A, suggesting a role of Coro1A in modulating the tissue microenvironment toward a pro-tumorigenic state. Mechanistically, Coro1A physically interacts with TGF-β RI and regulates TGF-β-TGF-β RI signalling endosome stability, thereby controlling TGF-β-mediated macrophage polarization. Detailed in vitro experiments revealed stabilization of Coro 1A through its interaction with SUMOylated Raftlin protein. Overall, Coro 1A is necessary and sufficient for TGF-β signalling, macrophage polarization, and tumorigenesis in CAC.
Open AccessCoronin1A regulates tumor microenvironment in colitis-associated colorectal cancer in a SUMO-dependent way
Inflammatory bowel disease (IBD), comprising Crohn’s disease and Ulcerative colitis, is a group of multifactorial illnesses with persistent gastrointestinal inflammation and a series of undesirable consequences. IBD patients have a three times higher risk of developing colitis-associated colorectal cancer (CAC). A higher mutational burden due to persistent inflammation acts as a driver of dysplasia and even tumorigenesis. While the pathological sequence is known, the molecular mechanisms underlying the transition from chronic inflammation to CAC remain largely elusive. Post-translational modification- SUMOylation plays an integral role in shaping gut inflammation as well as several forms of cancers, including sporadic colorectal cancer. In this study, the contribution of SUMOylation to CAC pathogenesis was characterized. In the AOM-DSS CAC mice model and human IBD patient specimens, SENP5, but not other deSUMOylases, shows an altered expression. Notably, both SENP5 expression dynamics and alterations in the SUMOylome occur in chronically inflamed and neoplastic colon tissues. SENP5 interactome analysis identified Coronin1A (Coro1A), an actin-binding protein predominantly expressed in immune cells. Coro1A also shows a state-specific, distinct expression pattern in the colon. Interestingly, in contrast to wild-type mice, Coro 1A knockout mice were resistant to polyp formation, with reduced cell proliferation, oncogene expression, and epithelial-to-mesenchymal transition (EMT) gene activation, and reduced extracellular matrix (ECM) development and fibrosis, suggesting its integral role in tumorigenesis. WT mice with chronically inflamed colons and polyps have a higher number of M2-like macrophages, with increased abundance of Coro1A, suggesting a role of Coro1A in modulating the tissue microenvironment toward a pro-tumorigenic state. Mechanistically, Coro1A physically interacts with TGF-β RI and regulates TGF-β-TGF-β RI signalling endosome stability, thereby controlling TGF-β-mediated macrophage polarization. Detailed in vitro experiments revealed stabilization of Coro 1A through its interaction with SUMOylated Raftlin protein. Overall, Coro 1A is necessary and sufficient for TGF-β signalling, macrophage polarization, and tumorigenesis in CAC.
- 10 December 2025
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 74
Patient interests and perspectives regarding robotic-assisted total joint arthroplasty in India: A cross-sectional study
- 10 December 2025
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 74
Patient interests and perspectives regarding robotic-assisted total joint arthroplasty in India: A cross-sectional study
- Open Access
- 27 October 2025
- Published by Medip Academy in International Journal of Research in Orthopaedics
- Vol. 11 (6) , 1412-1421
Latitud total hip replacement system in younger and older patients: a comprehensive multi-center assessment of clinical and functional outcomes
Background: Total hip arthroplasty (THA) is a standard treatment for end-stage hip disease. With rising demand across age groups, evaluating implant performance in younger and older patients is important. The Latitud total hip replacement system (HRS) is a novel implant,with no data on its safety and performance in younger patinets. Hence, We aimed to evaluate safety and functional outcomes of the Latitud HRS in younger (≤40 years) and older (>40 years) patients undergoing unilateral or bilateral THA. Methods: This prospective multicenter study across 11 Indian centers enrolled 192 patients undergoing primary THA with the Latitud HRS, followed for 2 years. Primary outcomes were implant survivorship and revision rates; secondary outcomes were clinical improvement using Harris Hip Score (HHS), Oxford Hip Score (OHS), and adverse events. Results: Of 192 patients, 67 were ≤40 years (55 unilateral, 12 bilateral) and 125 were >40 years (119 unilateral, 6 bilateral). Avascular necrosis predominated in younger patients, while osteoarthritis dominated older cases. At 2 years, OHS improved significantly in all groups: younger (unilateral 10.18±3.39 to 43.76±4.8; bilateral 8.75±2.83 to 43.08±4.01) and older (unilateral 8.06±4.67 to 43.69±4.68; bilateral 10.83±0.98 to 44.67±5.82). HHS also increased substantially: younger (unilateral 23.58±8.55 to 84.9±9.79; bilateral 19.71±10.93 to 89.4±5.07) and older (unilateral 18.16±12.13 to 86.38±7.89; bilateral 27.09±4.77 to 90). Implant survivorship was 100% in all except older unilateral (99.15%) due to one liner breakage. Conclusion: The Latitud HRS demonstrated excellent survivorship and functional recovery across both age groups, supporting its safety and durability in Indian patients, including younger adults with high functional demands.
- 27 October 2025
- Published by Medip Academy in International Journal of Research in Orthopaedics
- Vol. 11 (6) , 1412-1421
Open AccessLatitud total hip replacement system in younger and older patients: a comprehensive multi-center assessment of clinical and functional outcomes
Background: Total hip arthroplasty (THA) is a standard treatment for end-stage hip disease. With rising demand across age groups, evaluating implant performance in younger and older patients is important. The Latitud total hip replacement system (HRS) is a novel implant,with no data on its safety and performance in younger patinets. Hence, We aimed to evaluate safety and functional outcomes of the Latitud HRS in younger (≤40 years) and older (>40 years) patients undergoing unilateral or bilateral THA. Methods: This prospective multicenter study across 11 Indian centers enrolled 192 patients undergoing primary THA with the Latitud HRS, followed for 2 years. Primary outcomes were implant survivorship and revision rates; secondary outcomes were clinical improvement using Harris Hip Score (HHS), Oxford Hip Score (OHS), and adverse events. Results: Of 192 patients, 67 were ≤40 years (55 unilateral, 12 bilateral) and 125 were >40 years (119 unilateral, 6 bilateral). Avascular necrosis predominated in younger patients, while osteoarthritis dominated older cases. At 2 years, OHS improved significantly in all groups: younger (unilateral 10.18±3.39 to 43.76±4.8; bilateral 8.75±2.83 to 43.08±4.01) and older (unilateral 8.06±4.67 to 43.69±4.68; bilateral 10.83±0.98 to 44.67±5.82). HHS also increased substantially: younger (unilateral 23.58±8.55 to 84.9±9.79; bilateral 19.71±10.93 to 89.4±5.07) and older (unilateral 18.16±12.13 to 86.38±7.89; bilateral 27.09±4.77 to 90). Implant survivorship was 100% in all except older unilateral (99.15%) due to one liner breakage. Conclusion: The Latitud HRS demonstrated excellent survivorship and functional recovery across both age groups, supporting its safety and durability in Indian patients, including younger adults with high functional demands.