    Cuffless Blood Pressure Monitoring Devices: Technical Foundations and Clinical Implications

    by Gianfranco Parati, Juan Eugenio Ochoa, Ana Abreu, Sofie Brouwers, Rosa Maria Bruno, Enrico G Caiani, Ruben Casado-Arroyo, Matthijs Cluitmans, Constantinos H Davos, Raffaele De Lucia, et al.

    Cuffless blood pressure (BP) monitoring devices represent a promising innovation in hypertension management. This scientific statement provides a comprehensive update on these emerging technologies, their specific validation requirements, their potential clinical applications, and their present and future challenges. These devices generate considerable interest by enabling non-invasive BP measurement without arterial occlusion, thereby eliminating the discomfort associated with traditional cuff-based monitoring, particularly during sleep. The technologies on which these devices are based comprise a heterogeneous group, primarily utilizing pulse wave propagation time or waveform analysis through contact or non-contact sensors. They can be categorized as continuous or intermittent, automated or manual, calibration-free or requiring cuff/demographic calibration, and wearable or stationary. This technological diversity necessitates validation protocols distinct from those used for conventional cuff-based monitors, with specific requirements for each device category. Potential clinical applications include widespread out-of-office BP monitoring, unbiased assessment of circadian BP patterns and BP variability, improved detection of nocturnal hypertension, enhanced treatment adherence and long-term BP control, and continuous monitoring in hospital settings. Additionally, their lower cost compared with conventional technologies could enhance the early detection of hypertension in resource-limited settings. However, due to insufficient accuracy validation, this scientific statement does not recommend their use in clinical decisions in spite of their potential interest, in line with international guidelines not recommending their use in hypertension management. Key challenges ahead include developing standardized validation protocols, establishing normative BP data, managing the resulting burden on clinicians in handling huge volumes of data, exploring additional haemodynamic parameters, and advancing sensor technology, mathematical models, and algorithms.


  • Top Cited Papers
    Open Access

    Multi-specialty recommendations for the appropriate and affordable lower limb vein-lymphatic disorders management

    by Sergio Gianesini, Massimo Danese, Maurizio Pagano, Claudio Allegra, Deena Alqedrah, Giampiero Avruscio, Danila Azzolina, Enrico Cappello, Suat Doganci, Michelangelo Farina, et al.

    Article: Multi-specialty recommendations for the appropriate and affordable lower limb vein-lymphatic disorders management - International Angiology 2026 February;45(1):1-64 - Minerva Medica - Journals


  • Survey on Office Blood Pressure Measurement in Daily Practice in the Hypertension Centers of the Italian Society of Hypertension

    by Francesca Saladini, Fabiolucio Albini, Antonino Di Guardo, Gian Paolo Fra, Lucio Mos, Stefano Omboni, Pasquale Predotti, Franco Rabbia, Giuliano Tocci, Gianfranco Parati, et al.

    Introduction Office blood pressure (BP) measurement is the cornerstone for the diagnosis of arterial hypertension. Aim To investigate how office BP is measured in clinical practice among the hypertension centers of the Italian Society of Hypertension in comparison to what is recommend by the latest guidelines. Methods Coordinators of hypertension centers affiliated to the Italian Society of Hypertension were invited by email to complete an online survey including 26 questions regarding the equipment (devices and cuffs) available in the centers, office BP measurement procedure and possible additional measures performed by the devices. Results We obtained answers from 72 of the 119 centers (response rate 60.5%). The majority of the responders were older than 55 years (55.5%) and were from the North of Italy (61.1%). 95.6% stated the use of a validated device: 65.3% used automatic oscillometric devices, 27.8% an aneroid device, while 6.9% a manual device with a digital column. Unattended BP measurements were performed in 1.4% of the cases. Normal size cuff was available among 97.2% and large cuff among 83.1% of the centers. The majority tested BP in two different positions supine or sitting and standing positions, but there was a quarter of centers that measured BP only in one position. 38% of the responders performed three BP recordings, 38% at least two, but 5.7% measured BP only once. 42.3% of the devices used were able to detect atrial fibrillation. Conclusion Our survey depicted a considerable heterogeneity of office BP measurement methodology in daily practice, not always aligned with current guidelines.


  • Open Access

    Bridging the gap between hypertension guidelines and real-life practice: strategies and technological tools for improving long-term population blood pressure control

    by Grzegorz Bilo, Sofie Brouwers, Anastasios Kollias, Richard J McManus, Stefano Omboni, Aletta E Schutte, Gianfranco Parati

    Hypertension is the leading cardiovascular risk factor. However, despite the availability of safe and effective antihypertensive drugs, blood pressure (BP) control rates remain low worldwide. In this context, the recent European hypertension guidelines present an additional challenge by lowering the BP threshold for initiating pharmacological treatment to below 140/90 mmHg for selected high-risk patients and recommending that BP values be lowered to below 130/80 mmHg for most hypertensive patients. In this narrative review, we discuss the barriers to the implementation of guideline-defined standards of care in high-, low-, and middle-income countries and consider some possible solutions to improve this situation. We discuss strategies for detecting hypertension and monitoring its control, including new technologies and settings for BP measurement. Key issues related to the treatment of hypertension at the population level are also addressed, including lifestyle interventions, improving adherence to treatment, and organizational solutions, particularly for long-term follow-up of hypertensive patients. Finally, we identify key areas for future research into the implementation of hypertension care standards and attempt to suggest possible strategies that may be particularly relevant in the future, with the aim of improving global hypertension control rates and reducing the burden of its complications.


  • SURVEY ON OFFICE BLOOD PRESSURE MEASUREMENT DAILY PRACTICE IN THE HYPERTENSIVE CENTERS OF THE ITALIAN SOCIETY OF HYPERTENSION

    by Francesca Saladini, Fabio Lucio Albini, Antonino Di Guardo, Stefano Omboni, Gian Paolo Fra, Giuliano Tocci, Gianfranco Parati, Maria Lorenza Muiesan, Paolo Palatini, Grzegorz Bilo

  • Blood pressure measurement at kiosks in public spaces: systematic review and consensus statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability endorsed by the International Society of Hypertension and the World Hypertension League

    by George S. Stergiou, Konstantinos G. Kyriakoulis, Anastasios Kollias, Richard J. McManus, Ariadni Menti, Gianfranco Parati, Aletta E. Schutte, Jiguang Wang, Kei Asayama, Roland Asmar, et al.

    Kiosk devices for unsupervised self-measurement of blood pressure (BP) are being used in public spaces and healthcare settings in several countries. This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability provides a review of the published evidence on kiosk BP devices and consensus recommendations for their requirements and clinical use. A systematic literature search identified 54 relevant studies. Kiosk BP measurements appeared to be close to office BP [mean difference systolic 0.2 mmHg (95% confidence intervals −1.3 to 1.8); diastolic −0.4 mmHg (−3.5 to 2.7)], and higher than daytime ambulatory and home BP [mean difference 6.0 mmHg (1.6–10.4)/5.0 (2–8) and 8.1 mmHg (–2.6 to 18.9)/0.2 (−9.6 to 10.0), respectively]. Randomized or observational studies using kiosk BP measurements for hypertension screening or for assessing hypertension control were also included, as well as studies investigating users’ and healthcare professionals’ opinions, acceptability, and perspectives regarding kiosk BP measurements, and validation studies of kiosk BP devices. These studies had considerable heterogeneity in design, setting, methodology, measurement protocol, and sample size. Thus, at present, the clinical utility of kiosk BP measurements is uncertain. This ESH consensus statement acknowledges the potential of kiosk BP measurement as an emerging method for unsupervised self-measurement in the context of opportunistic screening for hypertension in apparently healthy people and the long-term monitoring of people with diagnosed hypertension. Requirements for the design, validation, function, and use of kiosk BP monitors are provided, together with the pending research questions on their optimal implementation in clinical practice.


  • Open Access

    Standards for the Implementation, Analysis, Interpretation, and Reporting of 24-hour Ambulatory Blood Pressure Monitoring Recommendations of the Italian Society of Hypertension

    by Stefano Omboni, Grzegorz Bilo, Francesca Saladini, Antonino Di Guardo, Paolo Palatini, Gianfranco Parati, Giacomo Pucci, Agostino Virdis, Maria Lorenza Muiesan

    Twenty-four-hour ambulatory blood pressure monitoring (ABPM) is recognized as a reference tool for accurately diagnosing hypertension. Until a few years ago, this technique was restricted to use by specialists. Recently, however, due to the need for wider availability and thanks to technological innovation, simplification of analysis processes, and increasing recognition of the importance of this tool for the diagnosis of hypertension, ABPM is now also being used in non-specialist settings. In such settings, ABPM is used with a two-pronged approach: (i) independently by a general practitioner with the possibility of specialist supervision for particular and complex cases; (ii) in the non-medical setting (community pharmacies, home care services, etc.) where the healthcare provider is trained in the proper use of the technique, with the understanding a physician must be responsible for the final clinical reporting. Unfortunately, due to the increasingly wide diffusion of ABPM, there has been considerable confusion about management roles and responsibilities in recent years. To clarify competencies and roles and standardize the processes related to the technique’s implementation and proper management, experts of the Blood Pressure Monitoring Working Group of the Italian Society of Hypertension have drafted this document with the aim of providing a quick and easy reference guide for training healthcare professionals in the field.


  • Open Access

    Association of 24-h central hemodynamics and stiffness with cardiovascular events and all-cause mortality. The VASOTENS Registry

    by Stefano Omboni, Jose Alfie, Ayana Arystan, Alberto Avolio, Edward Barin, Jamilya Bokusheva, Natalia Bulanova, Mark Butlin, Paula Cuffaro, Maria Derevyanchenko, et al.

    Objectives: In hemodialysis patients, central hemodynamics, stiffness, and wave reflections assessed through ambulatory blood pressure monitoring (ABPM) showed superior prognostic value for cardiovascular (CV) events than peripheral blood pressures (BPs). No such evidence is available for lower-risk hypertensive patients. Methods: In 591 hypertensive patients (mean age 58 ± 14 years, 49% males), ambulatory brachial and central BP, pulse wave velocity (PWV), and augmentation index (AIx) were obtained with a validated upper arm cuff-based pulse wave analysis technology. Information on treatment for hypertension (73% of patients), dyslipidemia (27%), diabetes (8%), CV disease history (25%), was collected. Patients were censored for CV events or all-cause death over 4.2 years. Results: One hundred and four events (24 fatal) were recorded. Advanced age [hazard ratio and 95% confidence interval: 1.03 (1.01, 1.05), P = 0.0001], female sex [1.57 (1.05, 2.33), P = 0.027], CV disease [2.22 (1.50, 3.29), P = 0.0001], increased 24-h central pulse pressure (PP) [1.56 (1.05, 2.31), P = 0.027], PWV [1.59 (1.07, 2.36), P = 0.022], or AIx [1.59 (1.08, 2.36), P = 0.020] were significantly associated with a worse prognosis (univariate Cox regression analysis). The prognostic power of peripheral and central BPs was lower. However, PWV [1.02 (0.64, 1.63), P = 0.924], AIx [1.06 (0.66, 1.69), P = 0.823], and central PP [1.18 (0.76, 1.82), P = 0.471], were not significant predictors in multivariate analyses. Conclusions: In hypertensive patients, ambulatory central PP, PWV, and AIx are associated with an increased risk of CV morbidity and all-cause mortality. However, this association is not independent of other patient characteristics.


  • AGE-RELATED BURDEN OF ARRHYTHMIA AND ITS ASSOCIATION WITH AMBULATORY BLOOD PRESSURE PROFILES AND CARDIOVASCULAR RISK LEVELS: RESULTS FROM THE TEMPLAR PROJECT

    by Kristina Lundwall, Thomas Kahan, Stefano Omboni

    Objective: Arrhythmia without known AF can be dangerous in subjects >55 years, since silent atrial fibrillation (AF), premature supraventricular contractions (PACs), and premature ventricular contractions (PVCs) all account for worse cardiovascular (CV) prognosis. Blood pressure (BP) levels and variability are important for the development of arrhythmia and CV outcome and might mediate these relations. However, no studies are performed in younger subjects, where extrasystoles occur frequently. Design and method: We included 12827 individuals without known AF undergoing a 24h ambulatory BP monitor (ABPM) including an algorithm for AF screening. Misclassification of PACs as silent AF occurs but is rare for PVCs. The arrhythmia burden was defined as the percentage of measurements with possible AF (silent AF and/or PACs) during 24h. Age stratification: (1) 20-40, (2) 41-50, (3) 51-60, (4) 61-70, (5) 71-80, (6) 81-100 years; group sizes were 1050 to 3373 individuals. Results: In groups 1-3 there were independent relations between arrhythmia burden and lower systolic and diastolic BP (beta -0.06 to -0.13, p 0.05 to <0.001), lower heart rate (beta -0.07 to -0.18, p <0.001), positive nocturnal dipping pattern (beta 0.04 to 0.07, p 0.05 to 0.005), and lower age (beta -0.04 to -0.25, p 0.02 to <0.001). In group 3 less CV disease (CVD) was related to arrhythmia burden (beta 0.06, p<0.001). In contrast, groups 5 and 6 showed independent relations between arrhythmia burden and higher diastolic BP (beta 0.08 to 0.13, p<0.001), older age (beta 0.11 to 0.10, p <0.001), and (in group 6) higher heart rate (beta 0.10, p <0.001), and negative nocturnal dipping pattern (beta 0.10, p 0.002). CVD was related to arrhythmia burden in groups 4-6 (beta 0.09 to 0.10 p 0.002 to <0.001). For all age groups, systolic and diastolic BP variability was independently related to arrhythmia burden (beta 0.06 to 0.23, p 0.05 to <0.001). Conclusions: In individuals without known AF aged 60 years, arrhythmia burden is related to an unfavorable ABPM profile and more CVD.

  • Open Access

    Predictors of Psychological Well-Being and Quality of Life in Patients with Hypertension: A Longitudinal Study

    by Maura Crepaldi, Jessica Giannì, Agostino Brugnera, Andrea Greco, Angelo Compare, Maria Luisa Rusconi, Barbara Poletti, Stefano Omboni, Giorgio Angelo Tasca, Gianfranco Parati

    Previous research has highlighted the positive impact of greater health-related quality of life (Hr-QoL) and subjective well-being (SWB) on chronic diseases’ severity and progression. There is a paucity of studies investigating the long-term trajectories of these variables among hypertensive patients. The present study aims to investigate the relationships between psychological variables (Type A and D personality, locus of control—LoC, self-esteem, and trait anxiety) with SWB and Hr-QoL in patients with hypertension and comorbid metabolic syndrome. A total of 185 volunteer patients (130 males, 70.3%; mean age 54 ± 10.93) were enrolled. Patients filled out measures of Hr-QoL and SWB, LoC, and self-esteem at three time points—Type A and D behaviors and anxiety measures only at baseline. Analyses were run through two-level hierarchical mixed models with repeated measures (Level 1) nested within participants (Level 2), controlling for sociodemographic and clinical confounders. Neither Hr-QoL nor SWB changed over time. Patients with greater self-esteem and internal LoC (and lower external LoC) increased their SWB and Hr-QoL up to 1-year follow-up. A greater Type A behavior and trait anxiety at baseline predicted a longitudinal increase in most of the dependent variables. Results suggest that it could be useful to tailor interventions targeting specific variables to increase Hr-QoL and SWB among hypertensive patients.