Stichting Hartcentrum Twente
Type
NonprofitLocations
Enschede, NetherlandsLatest Publications
- Open Access
- 23 June 2025
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 20 (1) , 267
En bloc versus branched graft technique for supra-aortic vessel reimplantation in total arch replacement: a systematic review and meta-analysis
Total arch replacement (TAR) necessitates reimplantation of supra-aortic vessels to preserve blood flow to the brain and upper body. En bloc (EB) or branched graft (BG) techniques are commonly performed for this, however, their comparative superiority remains under debate. Our meta-analysis aims to compare the outcomes associated with these two approaches. A comprehensive literature search was performed across MEDLINE, Cochrane, and Scopus databases, focusing on studies that compared EB and BG for TAR. Pooled odds ratios (OR) and mean differences (MD) with 95% confidence intervals (CI) were calculated using RevMan 8.13.0. The final analysis included six observational studies comprising a total of 2,028 patients, with 50.2% of supra-aortic vessel reimplantations for TAR conducted using the EB technique. The pooled results revealed a statistically significant reduction in aortic cross-clamp (ACC) time favouring the EB group [MD -13.2 min; 95% CI -22.7 to -3.7; p < 0.05]. Intraoperative and 30-day mortality as well as other postoperative complications such as permanent and transient neurological deficits, acute kidney injury, myocardial infarction, reoperation for bleeding, and aortic reintervention were comparable between the two approaches. The available evidence suggests that the EB technique is associated with a significantly shorter ACC time compared to the BG technique, with comparable rates of mortality and postoperative complications. However, these findings are limited by the observational nature of the included studies, therefore, higher-quality prospective research is needed to confirm our results.
- 23 June 2025
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 20 (1) , 267
Open AccessEn bloc versus branched graft technique for supra-aortic vessel reimplantation in total arch replacement: a systematic review and meta-analysis
Total arch replacement (TAR) necessitates reimplantation of supra-aortic vessels to preserve blood flow to the brain and upper body. En bloc (EB) or branched graft (BG) techniques are commonly performed for this, however, their comparative superiority remains under debate. Our meta-analysis aims to compare the outcomes associated with these two approaches. A comprehensive literature search was performed across MEDLINE, Cochrane, and Scopus databases, focusing on studies that compared EB and BG for TAR. Pooled odds ratios (OR) and mean differences (MD) with 95% confidence intervals (CI) were calculated using RevMan 8.13.0. The final analysis included six observational studies comprising a total of 2,028 patients, with 50.2% of supra-aortic vessel reimplantations for TAR conducted using the EB technique. The pooled results revealed a statistically significant reduction in aortic cross-clamp (ACC) time favouring the EB group [MD -13.2 min; 95% CI -22.7 to -3.7; p < 0.05]. Intraoperative and 30-day mortality as well as other postoperative complications such as permanent and transient neurological deficits, acute kidney injury, myocardial infarction, reoperation for bleeding, and aortic reintervention were comparable between the two approaches. The available evidence suggests that the EB technique is associated with a significantly shorter ACC time compared to the BG technique, with comparable rates of mortality and postoperative complications. However, these findings are limited by the observational nature of the included studies, therefore, higher-quality prospective research is needed to confirm our results.
- Open Access
- 8 August 2023
- Published by SAGE Publications in Perfusion
- Vol. 39 (7) , 1371-1379
Changes in colloid oncotic pressure during cardiac surgery with different prime fluid strategies
Objective: In cardiac surgery, colloid oncotic pressure (COP) is affected by haemodilution that results from composition and volume of prime fluid of cardiopulmonary bypass (CPB). However, the extent to which different priming strategies alter COP is largely unknown. Therefore, we investigated the effect of different priming strategies on COP in on-pump cardiac surgery. Methods: Patients ( n = 60) were divided into 3 groups ( n = 20 each), based on the center in which they were operated and the specific prime fluid strategy used in that center during the inclusion period. CPB prime fluids were either gelofusine-, albumin-, or crystalloid based, the latter two with or without retrograde autologous priming. Results: In all groups, COP was lowest after weaning from CPB and one hour after CPB. Between groups, COP was lowest with gelofusine prime fluid (16.4, 16.8 mmHg, respectively) compared with crystalloids (MD: -1.9; 95% CI:-3.6, -0.2; p = .02 and MD: -2.4, 95% CI: -4.2, -0.7; p = .002) and albumin (MD: -1.8, 95% CI: -3.5, -0.50; p = .041 and MD: -2.4, 95% CI: -4.1, -0.7; p = .002). In all groups, the decrease in COP one hour after bypass compared to baseline correlated positively with fluid balance at the end of surgery ( p < .001). Conclusions: COP significantly decrease during CPB surgery with the largest decrease in COP at the end of surgery, while at the same time fluid balance increases. We suggest that prime fluid strategy should be carefully selected when maintenance of COP during cardiac surgery is desirable.
- 8 August 2023
- Published by SAGE Publications in Perfusion
- Vol. 39 (7) , 1371-1379
Open AccessChanges in colloid oncotic pressure during cardiac surgery with different prime fluid strategies
Objective: In cardiac surgery, colloid oncotic pressure (COP) is affected by haemodilution that results from composition and volume of prime fluid of cardiopulmonary bypass (CPB). However, the extent to which different priming strategies alter COP is largely unknown. Therefore, we investigated the effect of different priming strategies on COP in on-pump cardiac surgery. Methods: Patients ( n = 60) were divided into 3 groups ( n = 20 each), based on the center in which they were operated and the specific prime fluid strategy used in that center during the inclusion period. CPB prime fluids were either gelofusine-, albumin-, or crystalloid based, the latter two with or without retrograde autologous priming. Results: In all groups, COP was lowest after weaning from CPB and one hour after CPB. Between groups, COP was lowest with gelofusine prime fluid (16.4, 16.8 mmHg, respectively) compared with crystalloids (MD: -1.9; 95% CI:-3.6, -0.2; p = .02 and MD: -2.4, 95% CI: -4.2, -0.7; p = .002) and albumin (MD: -1.8, 95% CI: -3.5, -0.50; p = .041 and MD: -2.4, 95% CI: -4.1, -0.7; p = .002). In all groups, the decrease in COP one hour after bypass compared to baseline correlated positively with fluid balance at the end of surgery ( p < .001). Conclusions: COP significantly decrease during CPB surgery with the largest decrease in COP at the end of surgery, while at the same time fluid balance increases. We suggest that prime fluid strategy should be carefully selected when maintenance of COP during cardiac surgery is desirable.
- 1 July 2019
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 12 (7) , e007734
Impact of Diabetes Mellitus in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents
Background: Data examining the impact of diabetes mellitus (DM) on ischemic risk after percutaneous coronary intervention in women are limited as most clinical trial participants are male. We evaluated (1) the impact of DM on ischemic outcomes in women undergoing drug-eluting stent (DES) implantation and (2) whether the outcomes of new- versus early-generation DES vary by DM status. Methods and Results: We pooled patient-level data of 10 448 women undergoing percutaneous coronary intervention with DES from 26 randomized trials. Baseline characteristics and 3-year clinical outcomes were stratified according to DM status (noninsulin-dependent and insulin-dependent) and DES generation. The primary end point was the composite of all-cause death or myocardial infarction. Secondary end points were definite or probable stent thrombosis and target lesion revascularization. Compared with women without DM (n=7154, 68.5%), adjusted risks (adjusted hazard ratios [95% CI]) for death or myocardial infarction among women with noninsulin-dependent DM (n=2241, 21.4%) and insulin-dependent DM (n=1053, 10.1%) were 1.30 (1.11–1.53) and 1.71 (1.41–2.07), respectively ( P trend <0.001). Similar trends were observed for def/prob stent thrombosis and target lesion revascularization. Compared with early-generation DES, use of newer-generation DES was associated with significant reductions in death or myocardial infarction in the absence of DM whereas differences were nonsignificant in the presence of DM, with similar findings for def/prob stent thrombosis and target lesion revascularization. Conclusions: The presence of DM is associated with substantial, graded, and durable risks for ischemic events among women undergoing percutaneous coronary intervention with DES. The safety and efficacy profile of newer-generation DES is preserved among women without DM, while benefits are nonsignificant among women with DM.
- 1 July 2019
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 12 (7) , e007734
Impact of Diabetes Mellitus in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents
Background: Data examining the impact of diabetes mellitus (DM) on ischemic risk after percutaneous coronary intervention in women are limited as most clinical trial participants are male. We evaluated (1) the impact of DM on ischemic outcomes in women undergoing drug-eluting stent (DES) implantation and (2) whether the outcomes of new- versus early-generation DES vary by DM status. Methods and Results: We pooled patient-level data of 10 448 women undergoing percutaneous coronary intervention with DES from 26 randomized trials. Baseline characteristics and 3-year clinical outcomes were stratified according to DM status (noninsulin-dependent and insulin-dependent) and DES generation. The primary end point was the composite of all-cause death or myocardial infarction. Secondary end points were definite or probable stent thrombosis and target lesion revascularization. Compared with women without DM (n=7154, 68.5%), adjusted risks (adjusted hazard ratios [95% CI]) for death or myocardial infarction among women with noninsulin-dependent DM (n=2241, 21.4%) and insulin-dependent DM (n=1053, 10.1%) were 1.30 (1.11–1.53) and 1.71 (1.41–2.07), respectively ( P trend <0.001). Similar trends were observed for def/prob stent thrombosis and target lesion revascularization. Compared with early-generation DES, use of newer-generation DES was associated with significant reductions in death or myocardial infarction in the absence of DM whereas differences were nonsignificant in the presence of DM, with similar findings for def/prob stent thrombosis and target lesion revascularization. Conclusions: The presence of DM is associated with substantial, graded, and durable risks for ischemic events among women undergoing percutaneous coronary intervention with DES. The safety and efficacy profile of newer-generation DES is preserved among women without DM, while benefits are nonsignificant among women with DM.
- Open Access
- 1 April 2018
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (17) , 2026-2035
First-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial
A second iteration of a sirolimus-eluting stent (SES) that has a biodegradable PLGA polymer coating with an electrografting base layer on a thin-strut (80 µm) cobalt-chromium platform (BuMA Supreme; SINOMED, Tianjin, China) has been developed. This first-in-man trial aimed to assess the efficacy and safety of the novel device. This randomised, multicentre, single-blinded, non-inferiority trial compared the BuMA Supreme SES versus a contemporary durable polymer zotarolimus-eluting stent (ZES) in terms of angiographic in-stent late lumen loss (LLL) at nine-month follow-up as the primary endpoint. A total of 170 patients were randomly allocated to treatment with either SES (n=83) or ZES (n=87). At nine-month angiographic follow-up, in-stent LLL was 0.29±0.33 mm in the SES group and 0.14±0.37 mm in the ZES group (pnon-inferiority=0.45). The in-stent percent diameter stenosis and the binary restenosis rate of the two treatment arms were similar (19.2±12.0% vs. 16.1±12.6%, p=0.09, and 3.3% vs. 4.4%, p=1.00, respectively). At 12-month clinical follow-up, there was no difference between treatment arms with regard to the device-oriented composite clinical endpoint (4.9% vs. 5.7%; p=0.72). The PIONEER trial did not meet its primary endpoint in terms of in-stent LLL at nine-month follow-up. However, this result did not translate into any increase in restenosis rate or impairment in 12-month clinical outcomes.
- 1 April 2018
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (17) , 2026-2035
Open AccessFirst-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial
A second iteration of a sirolimus-eluting stent (SES) that has a biodegradable PLGA polymer coating with an electrografting base layer on a thin-strut (80 µm) cobalt-chromium platform (BuMA Supreme; SINOMED, Tianjin, China) has been developed. This first-in-man trial aimed to assess the efficacy and safety of the novel device. This randomised, multicentre, single-blinded, non-inferiority trial compared the BuMA Supreme SES versus a contemporary durable polymer zotarolimus-eluting stent (ZES) in terms of angiographic in-stent late lumen loss (LLL) at nine-month follow-up as the primary endpoint. A total of 170 patients were randomly allocated to treatment with either SES (n=83) or ZES (n=87). At nine-month angiographic follow-up, in-stent LLL was 0.29±0.33 mm in the SES group and 0.14±0.37 mm in the ZES group (pnon-inferiority=0.45). The in-stent percent diameter stenosis and the binary restenosis rate of the two treatment arms were similar (19.2±12.0% vs. 16.1±12.6%, p=0.09, and 3.3% vs. 4.4%, p=1.00, respectively). At 12-month clinical follow-up, there was no difference between treatment arms with regard to the device-oriented composite clinical endpoint (4.9% vs. 5.7%; p=0.72). The PIONEER trial did not meet its primary endpoint in terms of in-stent LLL at nine-month follow-up. However, this result did not translate into any increase in restenosis rate or impairment in 12-month clinical outcomes.
- 1 January 2018
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 11 (1) , 53-65
Effect of Increasing Stent Length on 3-Year Clinical Outcomes in Women Undergoing Percutaneous Coronary Intervention With New-Generation Drug-Eluting Stents
- 1 January 2018
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 11 (1) , 53-65
Effect of Increasing Stent Length on 3-Year Clinical Outcomes in Women Undergoing Percutaneous Coronary Intervention With New-Generation Drug-Eluting Stents
- 1 January 2018
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 11 (1) , 68-76
Effects of Body Mass Index on Clinical Outcomes in Female Patients Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents
- 1 January 2018
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 11 (1) , 68-76
Effects of Body Mass Index on Clinical Outcomes in Female Patients Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents
- 12 December 2017
- Published by Springer Nature in Heart and Vessels
- Vol. 33 (6) , 595-604
Incidence of perioperative stroke in clampless aortic anastomosis during off-pump coronary artery bypass grafting
This study aimed to assess if clampless off-pump coronary artery bypass grafting (OPCAB) decreases the incidence of perioperative stroke (POS) rate and in-hospital mortality. The secondary aim was to evaluate 12-year rates of overall mortality. Between January 2003 to December 2015, data of 645 consecutive patients undergoing isolated CABG were retrospectively collected. 363 underwent aortic no-touch OPCAB (No-touch group) and 282 underwent OPCAB with the Heartstring device (HS group). In-hospital mortality and perioperative stroke rate as primary endpoint, as well as long-term follow-up outcome were analysed. In-hospital mortality was lower into No-touch group compared with HS group but without significant statistical difference (1.7 vs. 3.2%, p = 0.19, respectively); the rate of postoperative stroke was higher in No-touch group compared with HS group, although this difference did not reach statistically significance. Delirium was reported with higher presentation rate in HS group (3.9 vs. 0.8%, p = 0.01). Blood transfusions rate was higher in HS subjects (23.4 vs. 16.1%, p = 0.01). Intubation time, ICU, and hospital length of stay were increased in the HS group (p = 0.008, p = 0.001 and p = 0.003, respectively). Over a 12-year follow-up period, survival probabilities at 1, 5, and 10 years were 93.6 ± 1.3 vs. 93.2 ± 1.5, 80.4 ± 2.6 vs. 80.3 ± 2.2, and 57.9 ± 5 vs. 58.4 ± 3.8% in the No-touch and HS group, respectively (p = 0.97). In this retrospective study, clampless off-pump CABG lowers perioperative stroke rate whose incidence is, however, not inferior compared with No-touch technique, and no statistically significance was detected. Delirium has a higher presentation rate in clampless off-pump CABG.
- 12 December 2017
- Published by Springer Nature in Heart and Vessels
- Vol. 33 (6) , 595-604
Incidence of perioperative stroke in clampless aortic anastomosis during off-pump coronary artery bypass grafting
This study aimed to assess if clampless off-pump coronary artery bypass grafting (OPCAB) decreases the incidence of perioperative stroke (POS) rate and in-hospital mortality. The secondary aim was to evaluate 12-year rates of overall mortality. Between January 2003 to December 2015, data of 645 consecutive patients undergoing isolated CABG were retrospectively collected. 363 underwent aortic no-touch OPCAB (No-touch group) and 282 underwent OPCAB with the Heartstring device (HS group). In-hospital mortality and perioperative stroke rate as primary endpoint, as well as long-term follow-up outcome were analysed. In-hospital mortality was lower into No-touch group compared with HS group but without significant statistical difference (1.7 vs. 3.2%, p = 0.19, respectively); the rate of postoperative stroke was higher in No-touch group compared with HS group, although this difference did not reach statistically significance. Delirium was reported with higher presentation rate in HS group (3.9 vs. 0.8%, p = 0.01). Blood transfusions rate was higher in HS subjects (23.4 vs. 16.1%, p = 0.01). Intubation time, ICU, and hospital length of stay were increased in the HS group (p = 0.008, p = 0.001 and p = 0.003, respectively). Over a 12-year follow-up period, survival probabilities at 1, 5, and 10 years were 93.6 ± 1.3 vs. 93.2 ± 1.5, 80.4 ± 2.6 vs. 80.3 ± 2.2, and 57.9 ± 5 vs. 58.4 ± 3.8% in the No-touch and HS group, respectively (p = 0.97). In this retrospective study, clampless off-pump CABG lowers perioperative stroke rate whose incidence is, however, not inferior compared with No-touch technique, and no statistically significance was detected. Delirium has a higher presentation rate in clampless off-pump CABG.
- Open Access
- 1 August 2017
- Published by American Medical Association (AMA) in JAMA Cardiology
- Vol. 2 (8) , 855-862
Long-term Safety and Efficacy of New-Generation Drug-Eluting Stents in Women With Acute Myocardial Infarction
Women undergoing percutaneous coronary intervention (PCI) for acute myocardial infarction (MI) experience disproportionately higher rates of major adverse cardiovascular events (MACEs) and mortality compared with men.1-3 This observation may be partially explained by anatomical factors, as well as patient characteristics at the time of presentation. Women presenting with acute MI tend to be older and have greater prevalence of comorbidities than men.4,5 Additionally, women have often smaller and more tortuous coronary arteries and smaller mean luminal areas in the target lesions.6
- 1 August 2017
- Published by American Medical Association (AMA) in JAMA Cardiology
- Vol. 2 (8) , 855-862
Open AccessLong-term Safety and Efficacy of New-Generation Drug-Eluting Stents in Women With Acute Myocardial Infarction
Women undergoing percutaneous coronary intervention (PCI) for acute myocardial infarction (MI) experience disproportionately higher rates of major adverse cardiovascular events (MACEs) and mortality compared with men.1-3 This observation may be partially explained by anatomical factors, as well as patient characteristics at the time of presentation. Women presenting with acute MI tend to be older and have greater prevalence of comorbidities than men.4,5 Additionally, women have often smaller and more tortuous coronary arteries and smaller mean luminal areas in the target lesions.6
- 1 September 2016
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 9 (18) , 1890-1901
Correlates and Impact of Coronary Artery Calcifications in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents
- 1 September 2016
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 9 (18) , 1890-1901
Correlates and Impact of Coronary Artery Calcifications in Women Undergoing Percutaneous Coronary Intervention With Drug-Eluting Stents