TIB Molbiol (Germany)
Type
CompanyLocations
Berlin, GermanyLatest Publications
- Open Access
- 25 November 2026
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 12 (4) , 108
A Novel Approach for Newborn Screening Using High Multiplex Mutation Testing (HMMT)—A Concept Study for Metachromatic Leukodystrophy (MLD)
Metachromatic leukodystrophy (MLD) is a rare inherited lysosomal storage disorder that results from a deficiency of the arylsulfatase A (ARSA) enzyme and leads to progressive neurodegeneration and demyelination. Due to its narrow pre-symptomatic window of opportunity for disease-modifying therapies, the implementation of newborn screening (NBS) for MLD seems crucial and the incorporation of MLD screening into existing NBS programmes is required. In many NBS programmes, DNA-based assays have already been established, for instance, to screen for severe combined immunodeficiency, sickle cell disease, or spinal muscular atrophy. Utilizing these DNA eluates, we established high multiplex mutation testing (HMMT), a novel DNA-based method, as a genetic first-tier to screen for MLD. By multiplex allele-specific amplification, the assay detects thirteen frequent ARSA variants within the European population identifying newborns with MLD with a modelled, gnomAD-based sensitivity of approximately 92%. Anonymized DNA eluates from 3078 newborns were tested retrospectively. Variants were identified in nine samples (0.3%) confirmed by an allele-specific differentiation assay and next-generation sequencing. HMMT proved capable of identifying frequent ARSA variants as a genetic first-tier test, while panel composition and achievable sensitivity remain to be tested and optimized in a real-world cohort. When biochemical testing cannot be implemented as first-tier screening, our approach might be useful to set up as simple screening algorithm for MLD.
- 25 November 2026
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 12 (4) , 108
Open AccessA Novel Approach for Newborn Screening Using High Multiplex Mutation Testing (HMMT)—A Concept Study for Metachromatic Leukodystrophy (MLD)
Metachromatic leukodystrophy (MLD) is a rare inherited lysosomal storage disorder that results from a deficiency of the arylsulfatase A (ARSA) enzyme and leads to progressive neurodegeneration and demyelination. Due to its narrow pre-symptomatic window of opportunity for disease-modifying therapies, the implementation of newborn screening (NBS) for MLD seems crucial and the incorporation of MLD screening into existing NBS programmes is required. In many NBS programmes, DNA-based assays have already been established, for instance, to screen for severe combined immunodeficiency, sickle cell disease, or spinal muscular atrophy. Utilizing these DNA eluates, we established high multiplex mutation testing (HMMT), a novel DNA-based method, as a genetic first-tier to screen for MLD. By multiplex allele-specific amplification, the assay detects thirteen frequent ARSA variants within the European population identifying newborns with MLD with a modelled, gnomAD-based sensitivity of approximately 92%. Anonymized DNA eluates from 3078 newborns were tested retrospectively. Variants were identified in nine samples (0.3%) confirmed by an allele-specific differentiation assay and next-generation sequencing. HMMT proved capable of identifying frequent ARSA variants as a genetic first-tier test, while panel composition and achievable sensitivity remain to be tested and optimized in a real-world cohort. When biochemical testing cannot be implemented as first-tier screening, our approach might be useful to set up as simple screening algorithm for MLD.
- Open Access
- 2 September 2026
- Published by MDPI AG in Preprints.org
A Novel Approach for Newborn Screening Using High Multiplex Mutation Testing (HMMT) — A Concept Study for Metachromatic Leukodystrophy (MLD)
Metachromatic leukodystrophy (MLD) is a rare inherited lysosomal storage disorder that results from a deficiency of the arylsulfatase A (ARSA) enzyme and leads to progressive neurodegeneration and demyelination. Due to its narrow pre-symptomatic window of opportunity for disease-modifying therapies, the implementation of newborn screening (NBS) for MLD seems crucial and the incorporation of MLD screening into existing NBS programs is required. In many NBS programs, DNA-based assays have already been established, for instance to screen for severe combined immunodeficiency, sickle cell disease, or spinal muscular atrophy. Utilizing these DNA eluates, we established high-multiplex mutation testing (HMMT), a novel DNA-based method, as a genetic first-tier to screen for MLD. By multiplex allele-specific amplification, the assay detects thirteen frequent ARSA variants within the European population identifying newborns with MLD with a modelled, gnomAD-based sensitivity of approximately 92%. Anonymized DNA eluates from 3,078 newborns were tested retrospectively. Variants were identified in nine samples (0.3%) confirmed by an allele-specific differentiation assay and next-generation sequencing. HMMT proved capable to identify frequent ARSA variants as a genetic first-tier test, while panel composition and achievable sensitivity remain to be tested and optimised in a real-world cohort. When biochemical testing cannot be implemented as first tier screening, our approach might be useful to set up as simple screening algorithm for MLD.
- 2 September 2026
- Published by MDPI AG in Preprints.org
Open AccessA Novel Approach for Newborn Screening Using High Multiplex Mutation Testing (HMMT) — A Concept Study for Metachromatic Leukodystrophy (MLD)
Metachromatic leukodystrophy (MLD) is a rare inherited lysosomal storage disorder that results from a deficiency of the arylsulfatase A (ARSA) enzyme and leads to progressive neurodegeneration and demyelination. Due to its narrow pre-symptomatic window of opportunity for disease-modifying therapies, the implementation of newborn screening (NBS) for MLD seems crucial and the incorporation of MLD screening into existing NBS programs is required. In many NBS programs, DNA-based assays have already been established, for instance to screen for severe combined immunodeficiency, sickle cell disease, or spinal muscular atrophy. Utilizing these DNA eluates, we established high-multiplex mutation testing (HMMT), a novel DNA-based method, as a genetic first-tier to screen for MLD. By multiplex allele-specific amplification, the assay detects thirteen frequent ARSA variants within the European population identifying newborns with MLD with a modelled, gnomAD-based sensitivity of approximately 92%. Anonymized DNA eluates from 3,078 newborns were tested retrospectively. Variants were identified in nine samples (0.3%) confirmed by an allele-specific differentiation assay and next-generation sequencing. HMMT proved capable to identify frequent ARSA variants as a genetic first-tier test, while panel composition and achievable sensitivity remain to be tested and optimised in a real-world cohort. When biochemical testing cannot be implemented as first tier screening, our approach might be useful to set up as simple screening algorithm for MLD.
- Open Access
- 9 February 2026
- Published by Wiley in Journal of Medical Virology
- Vol. 98 (2) , e70824
Development of a Fully Automated, High‐Throughput Molecular Assay for Detection of Rat Hepatitis E Virus in Routine Diagnostics
Recently, cases of human infection with rat hepatitis E virus (ratHEV, Rocahepevirus ratti ) have been reported worldwide. Due to the significant genetic differences between ratHEV and human HEV genotypes 1–4 ( Paslahepevirus balayani ), current HEV diagnostic assays are unable to detect ratHEV. The aim was to establish and validate a laboratory‐developed ratHEV RT‐qPCR assay for use with human plasma and stool samples on a fully automated, high‐throughput platform. Published primers and probes were optimized for use on cobas 5800/6800/8800 systems using European Union In Vitro Diagnostics Regulation (IVDR)‐grade reagents, including an RNA full‐process inhibition control. Analytical sensitivity (21 repeats), linear range (five repeats) and precision (three repeats over 3 days) were evaluated using viral particles from cell culture (MN450851.1). The inclusivity was verified using DNA oligonucleotides and known positive samples (rat liver and human serum). The limits of detection were 98.9 copies/ml in plasma and 60.3 copies/ml in stool, and the assay showed excellent linearity over at least 5 log (r 2 : 0.991 in plasma and 0.9989 in stool) and high precision (< 0.62 ct). The assay reliably detected different ratHEV C1 subgenotypes, returning positive results for all 11 rat liver samples and one known ratHEV RNA‐positive human plasma sample, while no false positives were detected in the broad cross‐reactivity set ( n = 41). In the pilot ratHEV surveillance cohort, 1.1% of plasma samples ( n = 1999) were positive for HEV RNA, but none were positive for ratHEV RNA. Our new, fully automated, lab‐developed ratHEV assay can be used in compliance with the IVDR for routine human diagnostics. Further studies are needed to determine the clinical relevance in different human cohorts.
- 9 February 2026
- Published by Wiley in Journal of Medical Virology
- Vol. 98 (2) , e70824
Open AccessDevelopment of a Fully Automated, High‐Throughput Molecular Assay for Detection of Rat Hepatitis E Virus in Routine Diagnostics
Recently, cases of human infection with rat hepatitis E virus (ratHEV, Rocahepevirus ratti ) have been reported worldwide. Due to the significant genetic differences between ratHEV and human HEV genotypes 1–4 ( Paslahepevirus balayani ), current HEV diagnostic assays are unable to detect ratHEV. The aim was to establish and validate a laboratory‐developed ratHEV RT‐qPCR assay for use with human plasma and stool samples on a fully automated, high‐throughput platform. Published primers and probes were optimized for use on cobas 5800/6800/8800 systems using European Union In Vitro Diagnostics Regulation (IVDR)‐grade reagents, including an RNA full‐process inhibition control. Analytical sensitivity (21 repeats), linear range (five repeats) and precision (three repeats over 3 days) were evaluated using viral particles from cell culture (MN450851.1). The inclusivity was verified using DNA oligonucleotides and known positive samples (rat liver and human serum). The limits of detection were 98.9 copies/ml in plasma and 60.3 copies/ml in stool, and the assay showed excellent linearity over at least 5 log (r 2 : 0.991 in plasma and 0.9989 in stool) and high precision (< 0.62 ct). The assay reliably detected different ratHEV C1 subgenotypes, returning positive results for all 11 rat liver samples and one known ratHEV RNA‐positive human plasma sample, while no false positives were detected in the broad cross‐reactivity set ( n = 41). In the pilot ratHEV surveillance cohort, 1.1% of plasma samples ( n = 1999) were positive for HEV RNA, but none were positive for ratHEV RNA. Our new, fully automated, lab‐developed ratHEV assay can be used in compliance with the IVDR for routine human diagnostics. Further studies are needed to determine the clinical relevance in different human cohorts.
- Open Access
- 29 January 2025
- Published by Elsevier in The Lancet Global Health
- Vol. 13 (2) , e256-e267
Emergence and spread of the SARS-CoV-2 omicron (BA.1) variant across Africa: an observational study
- 29 January 2025
- Published by Elsevier in The Lancet Global Health
- Vol. 13 (2) , e256-e267
Open AccessEmergence and spread of the SARS-CoV-2 omicron (BA.1) variant across Africa: an observational study
- Open Access
- 21 January 2025
- Published by Oxford University Press (OUP) in Clinical and Experimental Immunology
- Vol. 219 (1)
Type I interferon signature: a quantitative standardized method for clinical application
Type I Interferon (IFN) induced gene expression analysis (“IFN signature”) is employed to categorize pathological conditions that exhibit Type I IFN dysregulation and to direct customized therapeutic strategies. For instance, it is used to differentiate patients with IFN-related inflammation from those with conditions primarily mediated by other cytokines, such as juvenile idiopathic arthritis and periodic fevers. Nevertheless, there is currently no standardized method available for clinical practice, and comparing values at different time points or between centers poses a challenge. In this work, we described a standardized method based on the development and validation of a synthetic control to solve the problem of test comparison. Inter-assay and inter-laboratory variability were assessed by multiple repeated analyses within the same laboratory, and between two different laboratories involved in the study. The method has been validated by evaluating the IFN signature of 39 patients with inflammatory disorders known to be related or not to Type I IFN (i.e. monogenic interferonopathies, systemic lupus erythematosus, juvenile dermatomyositis, periodic fevers, and juvenile idiopathic arthritis). The proposed method proved to be highly reproducible among centers and able to discriminate among IFN-related or non-IFN-related inflammation. The use of a synthetic control minimized the inter-assay and inter-laboratory variability, and thus facilitate data sharing among centers to improve knowledge of IFN-related inflammation and patient’s care.
- 21 January 2025
- Published by Oxford University Press (OUP) in Clinical and Experimental Immunology
- Vol. 219 (1)
Open AccessType I interferon signature: a quantitative standardized method for clinical application
Type I Interferon (IFN) induced gene expression analysis (“IFN signature”) is employed to categorize pathological conditions that exhibit Type I IFN dysregulation and to direct customized therapeutic strategies. For instance, it is used to differentiate patients with IFN-related inflammation from those with conditions primarily mediated by other cytokines, such as juvenile idiopathic arthritis and periodic fevers. Nevertheless, there is currently no standardized method available for clinical practice, and comparing values at different time points or between centers poses a challenge. In this work, we described a standardized method based on the development and validation of a synthetic control to solve the problem of test comparison. Inter-assay and inter-laboratory variability were assessed by multiple repeated analyses within the same laboratory, and between two different laboratories involved in the study. The method has been validated by evaluating the IFN signature of 39 patients with inflammatory disorders known to be related or not to Type I IFN (i.e. monogenic interferonopathies, systemic lupus erythematosus, juvenile dermatomyositis, periodic fevers, and juvenile idiopathic arthritis). The proposed method proved to be highly reproducible among centers and able to discriminate among IFN-related or non-IFN-related inflammation. The use of a synthetic control minimized the inter-assay and inter-laboratory variability, and thus facilitate data sharing among centers to improve knowledge of IFN-related inflammation and patient’s care.
- 8 January 2025
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 112 (1) , 79-84
Detection of Bacterial Infections and Malaria among Blood Culture-Negative Samples of Hospitalized Febrile Patients from a Tertiary Hospital in Ethiopia
: Febrile illnesses contribute significantly to morbidity and mortality in sub-Saharan Africa, but the lack of diagnostic facilities and the broad spectrum of pathogens can lead to inadequate clinical management. The timely and reliable identification of the causative pathogens in febrile patients is the basis for the administration of optimal treatment. We aimed to evaluate the performance of a multiplex polymerase chain reaction (PCR) among blood culture-negative patients presenting with febrile diseases in Central Ethiopia. From April 2016 to June 2018, we collected blood samples from adults and children ≥1 year of age admitted with febrile diseases to the Asella Referral and Teaching Hospital, which is located at an altitude of 2,400 m. Total nucleic acids were extracted from frozen plasma samples using a MagNA Pure 96 instrument (Roche, Mannheim, Germany). The multiplex PCR assays were used in combination with LightCycler multiplex DNA master mix (Roche) on a LightCycler 480 instrument (Roche). We used the pathogen-specific assays targeted to Plasmodium spp., Borrelia spp., Rickettsia spp., Leptospira spp., Salmonella spp., and arboviruses. We tested plasma samples of 511 patients and found positive results for Plasmodium spp. (13, 2.5%), Borrelia spp. (12, 2.3%), and Rickettsia species (7, 1.3%); in total, pathogens were detected in 32 of the samples (6.3%). No pathogen was detected by multiplex PCR in 94% of blood culture-negative samples. Even if the pathogens identified by PCR were not necessarily causes of fever, molecular testing using a multiplex PCR can contribute to pathogen diagnosis in a proportion of febrile patients in the highland part of Ethiopia and help to improve the clinical management.
- 8 January 2025
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 112 (1) , 79-84
Detection of Bacterial Infections and Malaria among Blood Culture-Negative Samples of Hospitalized Febrile Patients from a Tertiary Hospital in Ethiopia
: Febrile illnesses contribute significantly to morbidity and mortality in sub-Saharan Africa, but the lack of diagnostic facilities and the broad spectrum of pathogens can lead to inadequate clinical management. The timely and reliable identification of the causative pathogens in febrile patients is the basis for the administration of optimal treatment. We aimed to evaluate the performance of a multiplex polymerase chain reaction (PCR) among blood culture-negative patients presenting with febrile diseases in Central Ethiopia. From April 2016 to June 2018, we collected blood samples from adults and children ≥1 year of age admitted with febrile diseases to the Asella Referral and Teaching Hospital, which is located at an altitude of 2,400 m. Total nucleic acids were extracted from frozen plasma samples using a MagNA Pure 96 instrument (Roche, Mannheim, Germany). The multiplex PCR assays were used in combination with LightCycler multiplex DNA master mix (Roche) on a LightCycler 480 instrument (Roche). We used the pathogen-specific assays targeted to Plasmodium spp., Borrelia spp., Rickettsia spp., Leptospira spp., Salmonella spp., and arboviruses. We tested plasma samples of 511 patients and found positive results for Plasmodium spp. (13, 2.5%), Borrelia spp. (12, 2.3%), and Rickettsia species (7, 1.3%); in total, pathogens were detected in 32 of the samples (6.3%). No pathogen was detected by multiplex PCR in 94% of blood culture-negative samples. Even if the pathogens identified by PCR were not necessarily causes of fever, molecular testing using a multiplex PCR can contribute to pathogen diagnosis in a proportion of febrile patients in the highland part of Ethiopia and help to improve the clinical management.
- Open Access
A Modular Genetic Approach to Newborn Screening from Spinal Muscular Atrophy to Sickle Cell Disease—Results from Six Years of Genetic Newborn Screening
Background/Objectives: Genetic newborn screening (NBS) has already entered the phase of common practice in many countries. In Germany, spinal muscular atrophy (SMA), severe combined immunodeficiency (SCID) and sickle cell disease (SCD) are currently a mandatory part of NBS. Here, we describe the experience of six years of genetic NBS including the prevalence of those three diseases in Germany. Methods: Samples and nucleic acids were extracted from dried blood spot cards, commonly used for NBS. A qPCR assay was used to detect disease-causing variants for SMA and SCD, and the detection of T-cell receptor excision circles (TRECs) was performed for SCID screening. Results: The results of the NBS of over 1 million newborns for SMA, approximately 770,000 for SCID and over 410,000 for SCD are discussed in detail. In these newborns, we have identified 121 cases of SMA, 15 cases of SCID and syndrome-based immunodeficiencies and 77 cases of SCD or β-thalassemia. Conclusions: The flexibility of multiplex qPCR is assessed as an effective tool for incorporating different molecular genetic markers for screening. The processing of dried blood spot (DBS) filter cards for molecular genetic assays and the assays are described in detail; turn-around times and cost estimations are included to give an insight into the processes and discuss further options for optimization. The identified cases are in the range expected for the total number of screened newborns, but present a more exact view on the actual prevalences for Germany.
Open AccessA Modular Genetic Approach to Newborn Screening from Spinal Muscular Atrophy to Sickle Cell Disease—Results from Six Years of Genetic Newborn Screening
Background/Objectives: Genetic newborn screening (NBS) has already entered the phase of common practice in many countries. In Germany, spinal muscular atrophy (SMA), severe combined immunodeficiency (SCID) and sickle cell disease (SCD) are currently a mandatory part of NBS. Here, we describe the experience of six years of genetic NBS including the prevalence of those three diseases in Germany. Methods: Samples and nucleic acids were extracted from dried blood spot cards, commonly used for NBS. A qPCR assay was used to detect disease-causing variants for SMA and SCD, and the detection of T-cell receptor excision circles (TRECs) was performed for SCID screening. Results: The results of the NBS of over 1 million newborns for SMA, approximately 770,000 for SCID and over 410,000 for SCD are discussed in detail. In these newborns, we have identified 121 cases of SMA, 15 cases of SCID and syndrome-based immunodeficiencies and 77 cases of SCD or β-thalassemia. Conclusions: The flexibility of multiplex qPCR is assessed as an effective tool for incorporating different molecular genetic markers for screening. The processing of dried blood spot (DBS) filter cards for molecular genetic assays and the assays are described in detail; turn-around times and cost estimations are included to give an insight into the processes and discuss further options for optimization. The identified cases are in the range expected for the total number of screened newborns, but present a more exact view on the actual prevalences for Germany.
- Open Access
- 28 June 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (6) , e0306329
Quality considerations and major pitfalls for high throughput DNA-based newborn screening for severe combined immunodeficiency and spinal muscular atrophy
Background: Many newborn screening programs worldwide have introduced screening for diseases using DNA extracted from dried blood spots (DBS). In Germany, DNA-based assays are currently used to screen for severe combined immunodeficiency (SCID), spinal muscular atrophy (SMA), and sickle cell disease (SCD). Methods: This study analysed the impact of pre-analytic DNA carry-over in sample preparation on the outcome of DNA-based newborn screening for SCID and SMA and compared the efficacy of rapid extraction versus automated protocols. Additionally, the distribution of T cell receptor excision circles (TREC) on DBS cards, commonly used for routine newborn screening, was determined. Results: Contaminations from the punching procedure were detected in the SCID and SMA assays in all experimental setups tested. However, a careful evaluation of a cut-off allowed for a clear separation of true positive polymerase chain reaction (PCR) amplifications. Our rapid in-house extraction protocol produced similar amounts compared to automated commercial systems. Therefore, it can be used for reliable DNA-based screening. Additionally, the amount of extracted DNA significantly differs depending on the location of punching within a DBS. Conclusions: Newborn screening for SMA and SCID can be performed reliably. It is crucial to ensure that affected newborns are not overlooked. Therefore a carefully consideration of potential contaminating factors and the definition of appropriate cut-offs to minimise the risk of false results are of special concern. It is also important to note that the location of punching plays a pivotal role, and therefore an exact quantification of TREC numbers per μl may not be reliable and should therefore be avoided.
- 28 June 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (6) , e0306329
Open AccessQuality considerations and major pitfalls for high throughput DNA-based newborn screening for severe combined immunodeficiency and spinal muscular atrophy
Background: Many newborn screening programs worldwide have introduced screening for diseases using DNA extracted from dried blood spots (DBS). In Germany, DNA-based assays are currently used to screen for severe combined immunodeficiency (SCID), spinal muscular atrophy (SMA), and sickle cell disease (SCD). Methods: This study analysed the impact of pre-analytic DNA carry-over in sample preparation on the outcome of DNA-based newborn screening for SCID and SMA and compared the efficacy of rapid extraction versus automated protocols. Additionally, the distribution of T cell receptor excision circles (TREC) on DBS cards, commonly used for routine newborn screening, was determined. Results: Contaminations from the punching procedure were detected in the SCID and SMA assays in all experimental setups tested. However, a careful evaluation of a cut-off allowed for a clear separation of true positive polymerase chain reaction (PCR) amplifications. Our rapid in-house extraction protocol produced similar amounts compared to automated commercial systems. Therefore, it can be used for reliable DNA-based screening. Additionally, the amount of extracted DNA significantly differs depending on the location of punching within a DBS. Conclusions: Newborn screening for SMA and SCID can be performed reliably. It is crucial to ensure that affected newborns are not overlooked. Therefore a carefully consideration of potential contaminating factors and the definition of appropriate cut-offs to minimise the risk of false results are of special concern. It is also important to note that the location of punching plays a pivotal role, and therefore an exact quantification of TREC numbers per μl may not be reliable and should therefore be avoided.
- Open Access
- 18 June 2024
- Published by Public Library of Science (PLoS) in PLOS Neglected Tropical Diseases
- Vol. 18 (6) , e0012279
Evaluation of copromicroscopy, multiplex-qPCR and antibody serology for monitoring of human ascariasis in endemic settings
Background: The standard diagnosis of Ascaris lumbricoides and other soil-transmitted helminth (STH) infections relies on the detection of worm eggs by copromicroscopy. However, this method is dependent on worm patency and shows only limited accuracy in low-intensity infection settings. We aimed to decipher the diagnostic accuracy of different antibodies using various Ascaris antigens in reference to copromicroscopy and quantitative PCR (qPCR), four months after national STH preventative chemotherapy among school children in western Kenya. Methodology: STH infection status of 390 school children was evaluated via copromicroscopy (Kato-Katz and mini-FLOTAC) and qPCR. In parallel, Ascaris-specific antibody profiles against larval and adult worm lysates, and adult worm excretory-secretory (ES) products were determined by enzyme-linked immunosorbent assay. Antibody cross-reactivity was evaluated using the closely related zoonotic roundworm species Toxocara cati and Toxocara canis. The diagnostic accuracy of each antibody was evaluated using receiver operating curve analysis and the correspondent area under the curve (AUC). Principal findings: Ascaris was the predominant helminth infection with an overall prevalence of 14.9% (58/390). The sensitivity of mini-FLOTAC and Kato-Katz for Ascaris diagnosis reached only 53.5% and 63.8%, respectively compared to qPCR. Although being more sensitive, qPCR values correlated with microscopic egg counts (R = -0.71, PAscaris worms reliably diagnosed active Ascaris infection as determined by qPCR and microscopy, with IgG1 displaying the highest accuracy (AUC = 0.83, 95% CI: 0.75–0.91). Conclusion: IgG1 antibody responses against adult Ascaris-ES products hold a promising potential for complementing the standard fecal and molecular techniques employed for monitoring Ascaris infections. This is of particular importance in the context of deworming programs as the antibody diagnostic accuracy was independent of egg counts.
- 18 June 2024
- Published by Public Library of Science (PLoS) in PLOS Neglected Tropical Diseases
- Vol. 18 (6) , e0012279
Open AccessEvaluation of copromicroscopy, multiplex-qPCR and antibody serology for monitoring of human ascariasis in endemic settings
Background: The standard diagnosis of Ascaris lumbricoides and other soil-transmitted helminth (STH) infections relies on the detection of worm eggs by copromicroscopy. However, this method is dependent on worm patency and shows only limited accuracy in low-intensity infection settings. We aimed to decipher the diagnostic accuracy of different antibodies using various Ascaris antigens in reference to copromicroscopy and quantitative PCR (qPCR), four months after national STH preventative chemotherapy among school children in western Kenya. Methodology: STH infection status of 390 school children was evaluated via copromicroscopy (Kato-Katz and mini-FLOTAC) and qPCR. In parallel, Ascaris-specific antibody profiles against larval and adult worm lysates, and adult worm excretory-secretory (ES) products were determined by enzyme-linked immunosorbent assay. Antibody cross-reactivity was evaluated using the closely related zoonotic roundworm species Toxocara cati and Toxocara canis. The diagnostic accuracy of each antibody was evaluated using receiver operating curve analysis and the correspondent area under the curve (AUC). Principal findings: Ascaris was the predominant helminth infection with an overall prevalence of 14.9% (58/390). The sensitivity of mini-FLOTAC and Kato-Katz for Ascaris diagnosis reached only 53.5% and 63.8%, respectively compared to qPCR. Although being more sensitive, qPCR values correlated with microscopic egg counts (R = -0.71, PAscaris worms reliably diagnosed active Ascaris infection as determined by qPCR and microscopy, with IgG1 displaying the highest accuracy (AUC = 0.83, 95% CI: 0.75–0.91). Conclusion: IgG1 antibody responses against adult Ascaris-ES products hold a promising potential for complementing the standard fecal and molecular techniques employed for monitoring Ascaris infections. This is of particular importance in the context of deworming programs as the antibody diagnostic accuracy was independent of egg counts.