  • Open Access

    Design and validation of a bioactive and antimicrobial coating through advanced deposition strategies for biomedical applications

    by Giusy Sorvillo, Rosa Calderon-Jacinto, Yijie Li, Léa Magne, Cynthia Calligaro, Rémy Agniel, Grégory Francius, Nicolas Courtois, Philippe Lavalle, Damien Seyer, et al.

    Bifunctional PLL 30 /HA/Fn polyelectrolyte multilayer coatings engineered by Layer-by-Layer assembly to confer simultaneous antibacterial activity and cytocompatibility are translated to spray-assisted deposition for peri-implantitis management.


  • Open Access

    Bone mechanical behavior around dental implants: Densification and deformation follow-up by in-situ computed tomography

    by Laura Preiss, Rémy Gauthier, Hervé Richard, Loïc Courtois, Anne-Lise Chopard-Lallier, Damien Fabrègue, Jérôme Chevalier, Nicolas Courtois


  • Open Access

    Race for the surface between THP-1 macrophages and Staphylococcus aureus on various titanium implants with well-defined topography and wettability

    by Adam Benedict Turner, Paula Milena Giraldo-Osorno, Yohan Douest, Liliana Andrea Morales-Laverde, Carl Anton Bokinge, Farah Asa'AD, Nicolas Courtois, Anders Palmquist, Margarita Trobos


  • Open Access

    Bio‐Inspired Micro‐ and Nano‐Scale Surface Features Produced by Femtosecond Laser‐Texturing Enhance TiZr‐Implant Osseointegration

    by William Arthur Lackington, Benjamin Bellon, Stefanie Guimond, Peter Schweizer, Claudia Cancellieri, Antoine Ambeza, Anne‐Lise Chopard‐Lallier, Benjamin Pippenger, Andac Armutlulu, Xavier Maeder, et al.

    Surface design plays a critical role in determining the integration of dental implants with bone tissue. Femtosecond laser‐texturing has emerged as a breakthrough technology offering excellent uniformity and reproducibility in implant surface features. However, when compared to state‐of‐the‐art sandblasted and acid‐etched surfaces, laser‐textured surface designs typically underperform in terms of osseointegration. This study investigates the capacity of a bio‐inspired femtosecond laser‐textured surface design to enhance osseointegration compared to state‐of‐the‐art sandblasted & acid‐etched surfaces. Laser‐texturing facilitates the production of an organized trabeculae‐like microarchitecture with superimposed nano‐scale laser‐induced periodic surface structures on both 2D and 3D samples of titanium‐zirconium‐alloy. Following a boiling treatment to modify the surface chemistry, improving wettability to a contact angle of 10°, laser‐textured surfaces enhance fibrin network formation when in contact with human whole blood, comparable to state‐of‐the‐art surfaces. In vitro experiments demonstrate that laser‐textured surfaces significantly outperform state‐of‐the‐art surfaces with a 2.5‐fold higher level of mineralization by bone progenitor cells after 28 days of culture. Furthermore, in vivo evaluations reveal superior biomechanical integration of laser‐textured surfaces after 28 days of implantation. Notably, during abiological pull‐out tests, laser‐textured surfaces exhibit comparable performance, suggesting that the observed enhanced osseointegration is primarily driven by the biological response to the surface.


  • Open Access

    Machine learning-guided exploration and experimental assessment of unreported compositions in the quaternary Ti-Zr-Cu-Pd biocompatible metallic glass system

    by Yohan Douest, Robert M. Forrest, Benoit Ter-Ovanessian, Nicolas Courtois, Franck Tancret, A. Lindsay Greer, Jérôme Chevalier, Damien Fabrègue


  • Open Access

    Femtosecond Laser‐Texturing the Surface of Ti‐Based Implants to Improve Their Osseointegration Capacity

    by William A. Lackington, Peter Schweizer, Mariya Khokhlova, Claudia Cancellieri, Stefanie Guimond, Anne‐Lise Chopard‐Lallier, Joëlle Hofstetter, Patrik Schmutz, Xavier Maeder, Markus Rottmar

    In modern oral maxillofacial surgery, long‐term implant stability is intrinsically linked to the quality of osseointegration. While the osseointegration capacity of implants can be improved by modifying their surface properties, commonly used techniques, including sandblasting and acid etching, are stochastic processes offering virtually zero capacity to control the uniformity and reproducibility of micro‐ and nano‐scale surface features. In this study, titanium‐aluminium‐vanadium (TiAlV) implant surfaces are modified using femtosecond (fs) laser‐texturing, and its influence on physicochemical properties, on blood–implant interactions, and on the osseointegration potential is investigated in vitro. Laser‐texturing enables the production of designer surfaces with micro‐scale features defined in size and arrangement. While state of the art TiAlV surfaces prepared by sandblasting with biphasic calcium phosphate (BCP) show significant grain refinement at the near surface, fs laser‐texturing preserves the grain size and enhances the microstrain and oxide layer thickness but also leads to 15% lower bulk fatigue in comparison to BCP treatment. Blood coagulation is similar on laser‐textured and BCP surfaces, as is mineralization by human bone progenitor cells, albeit with a decreasing trend for laser‐textured surfaces. Laser‐texturing thus presents as a promising approach to create highly reproducible designer surfaces with biological performance comparable to state‐of‐the‐art implants.


  • Histologic and histomorphometric evaluation of new zirconia-based ceramic dental implants: A preclinical study in dogs

    by Doriane Chacun, Arnaud Lafon, Nicolas Courtois, Helen Reveron, Jérôme Chevalier, Patrice Margossian, Antoine Alves, Kerstin Gritsch, Brigitte Grosgogeat


  • Open Access

    Electrospun Bioresorbable Membrane Eluting Chlorhexidine for Dental Implants

    by Pierre Pouponneau, Ophélie Perrey, Céline Brunon, Carol Grossiord, Nicolas Courtois, Vincent Salles, Antoine Alves

    To prevent the uncontrolled development of a pathogenic biofilm around a dental implant, an antimicrobial drug-release electrospun membrane, set up between the implant and the gingival tissue, was developed by taking several technical, industrial and regulatory specifications into account. The membrane formulation is made of a blend of poly(l-lactic–co–gycolic acid) (PLGA, 85:15) and poly(l-lactic acide–co–ɛ-caprolactone) (PLC, 70:30) copolymers with chlorhexidine diacetate (CHX) complexed with β-cyclodextrin (CD). The amount of residual solvent, the mechanical properties and the drug release kinetics were tuned by the copolymers’ ratio, between 30% and 100% of PLC, and a CHX loading up to 20% w/w. The membranes were sterilized by γ-irradiation without significant property changes. The fiber′s diameter was between 600 nm and 3 µm, depending on the membrane composition and the electrospinning parameters. CHX was released in vitro over 10 days and the bacterial inhibitory concentration, 80 µg·mL−1, was reached within eight days. The optimal membrane, PGLA/PLC/CHX-CD (60%/40%/4%), exhibited a breaking strain of 50%, allowing its safe handling. This membrane and a membrane without CHX-CD were implanted subcutaneous in a rat model. The cell penetration remained low. The next step will be to increase the porosity of the membrane to improve the dynamic cell penetration and tissue remodeling.


  • Top Cited Papers

    Forty years after the promise of «ceramic steel?»: Zirconia‐based composites with a metal‐like mechanical behavior

    by Jérôme Chevalier, Aléthéa Liens, Helen Reveron, Fei Zhang, Pascal Reynaud, Thierry Douillard, Laura Preiss, Valter Sergo, Vanni Lughi, Mike Swain, et al.


  • Open Access

    On the Potential of Bulk Metallic Glasses for Dental Implantology: Case Study on Ti40Zr10Cu36Pd14

    by Alethea Liens, Aurélien Etiemble, Pascaline Rivory, Sandra Balvay, Jean-Marc Pelletier, Sandrine Cardinal, Damien Fabrègue, Hidemi Kato, Philippe Steyer, Tais Munhoz, et al.

    Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on machined implant-abutment assemblies. The results were compared to the benchmark Ti-6Al-4V ELI (Extra-Low-Interstitial) to assess its potential in dental implantology. The thermal stability, corrosion and sterilization resistance, cytocompatibility and mechanical properties were measured on samples with a simple geometry, but also on implant-abutment assemblies’ prototypes. Results show that the glassy alloy exhibits a quite high thermal stability, with a temperature range of 38 °C between the glass transition and crystallization, a compressive strength of 2 GPa, a certain plastic deformation (0.7%), a hardness of 5.5 GPa and a toughness of 56 MPa.√m. Moreover, the alloy shows a relatively lower Young’s modulus (96 GPa) than the Ti-6Al-4V alloy (110–115 GPa), which is beneficial to limit bone stress shielding. The BMG shows a satisfactory cytocompatibility, a high resistance to sterilization and a good corrosion resistance (corrosion potential of −0.07 V/SCE and corrosion current density of 6.0 nA/cm2), which may ensure its use as a biomaterial. Tests on dental implants reveal a load to failure 1.5-times higher than that of Ti-6Al-4V and a comparable fatigue limit. Moreover, implants could be machined and sandblasted by methods usually conducted for titanium implants, without significant degradation of their amorphous nature. All these properties place this metallic glass among a promising class of materials for mechanically-challenging applications such as dental implants.