Groupe de recherche et d'accueil en droit et économie de la santé
Latest Publications
- Open Access
- 9 March 2026
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 42 (1) , e25
Organizational impact in healthcare in France: a decade of insights but chicken and egg situation
Objectives: Over the past decade, organizational impact (OI) has gained recognition as a key dimension in health technology assessment (HTA) in France, particularly for medical devices. Despite the publication of a national framework by the Haute Autorité de Santé in 2020, the absence of standardized methodologies continues to hinder its integration into decision making. Methods: This commentary article traces the evolution of OI in French HTA, highlights real-world examples, and analyzes existing methodological tools, many adapted from other disciplines, that could enhance OI assessment. Results: It emphasizes the need for flexible, context-sensitive approaches and proposes recommendations to improve the robustness, reproducibility, and relevance of OI evaluations. Conclusions: The article also explores the implications for pricing and reimbursement decisions, as well as hospital-based HTA practices, aiming to support more structured and evidence-informed integration of organizational considerations into HTA processes in France and beyond.
- 9 March 2026
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 42 (1) , e25
Open AccessOrganizational impact in healthcare in France: a decade of insights but chicken and egg situation
Objectives: Over the past decade, organizational impact (OI) has gained recognition as a key dimension in health technology assessment (HTA) in France, particularly for medical devices. Despite the publication of a national framework by the Haute Autorité de Santé in 2020, the absence of standardized methodologies continues to hinder its integration into decision making. Methods: This commentary article traces the evolution of OI in French HTA, highlights real-world examples, and analyzes existing methodological tools, many adapted from other disciplines, that could enhance OI assessment. Results: It emphasizes the need for flexible, context-sensitive approaches and proposes recommendations to improve the robustness, reproducibility, and relevance of OI evaluations. Conclusions: The article also explores the implications for pricing and reimbursement decisions, as well as hospital-based HTA practices, aiming to support more structured and evidence-informed integration of organizational considerations into HTA processes in France and beyond.
- 4 December 2025
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 84 (3) , 517-528
Diffusion des dispositifs médicaux innovants dans les établissements de santé français : que nous apprennent les bases de données publiques ?
- 4 December 2025
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 84 (3) , 517-528
Diffusion des dispositifs médicaux innovants dans les établissements de santé français : que nous apprennent les bases de données publiques ?
- 29 January 2025
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 83 (4) , 720-728
Retraitement des dispositifs médicaux à usage unique : points de vue et perceptions des cardiologues et pharmaciens hospitaliers
- 29 January 2025
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 83 (4) , 720-728
Retraitement des dispositifs médicaux à usage unique : points de vue et perceptions des cardiologues et pharmaciens hospitaliers
- 14 November 2024
- Published by Elsevier in Journal of Epidemiology and Population Health
- Vol. 73 (1) , 202796
The digital mental health challenge in France
- 14 November 2024
- Published by Elsevier in Journal of Epidemiology and Population Health
- Vol. 73 (1) , 202796
The digital mental health challenge in France
- Open Access
- 11 August 2024
- Published by Elsevier in Health Policy
- Vol. 148, 105146
Early access programs for medical devices in France: Overview of recent reforms and outcomes (2015-2022)
- 11 August 2024
- Published by Elsevier in Health Policy
- Vol. 148, 105146
Open AccessEarly access programs for medical devices in France: Overview of recent reforms and outcomes (2015-2022)
- Open Access
- 14 December 2023
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 105 (4) , 144-150
Genicular artery embolization for knee osteoarthritis: Results of the LipioJoint-1 trial
- 14 December 2023
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 105 (4) , 144-150
Open AccessGenicular artery embolization for knee osteoarthritis: Results of the LipioJoint-1 trial
- 21 September 2023
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 39 (1) , e58
Hospital-based health technology assessment of innovative medical devices: insights from a nationwide survey in France
Objectives: To better understand the process of hospital acquisition of innovative medical devices (MDs) and the hospital-based health technology assessment (HB-HTA) pathways in France, an in-depth study based on a quantitative approach is needed. The aim of the present study was to assess through a national survey how HB-HTA is currently implemented in French hospitals and to identify its level of formalization. Methods: A quantitative online survey was conducted among hospitals performing HB-HTA in France, with a focus on the acquisition of innovative MDs for individual use. The survey, conducted between March and June 2022, was developed by a scientific board composed of members of the French-speaking Society for HB-HTA. Results: Sixty-seven out of 131 surveyed hospitals with HB-HTA activities responded, including 29 university hospitals, 24 nonprofit private hospitals, and 14 local hospitals. Sixty-one respondents (91 percent) reported the existence of a process dedicated to evaluating innovative MDs; of these, 16 declared that their hospitals had a formalized unit with HB-HTA activity. These units were more frequently found in larger hospitals with more than 500 inpatient beds (n = 16, p = 0.0160) and in university hospitals (n = 12, p = 0.0158). No hospital reported any collaboration with HAS, the French national HTA agency. Conclusion: A diverse range of HB-HTA organizations with different structural levels exist in France for MD procurement linked to the category of hospitals. The study highlights the need for recognition of HB-HTA activity at the regulatory level in France and for direct collaboration between HTA activities performed at local and national levels.
- 21 September 2023
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 39 (1) , e58
Hospital-based health technology assessment of innovative medical devices: insights from a nationwide survey in France
Objectives: To better understand the process of hospital acquisition of innovative medical devices (MDs) and the hospital-based health technology assessment (HB-HTA) pathways in France, an in-depth study based on a quantitative approach is needed. The aim of the present study was to assess through a national survey how HB-HTA is currently implemented in French hospitals and to identify its level of formalization. Methods: A quantitative online survey was conducted among hospitals performing HB-HTA in France, with a focus on the acquisition of innovative MDs for individual use. The survey, conducted between March and June 2022, was developed by a scientific board composed of members of the French-speaking Society for HB-HTA. Results: Sixty-seven out of 131 surveyed hospitals with HB-HTA activities responded, including 29 university hospitals, 24 nonprofit private hospitals, and 14 local hospitals. Sixty-one respondents (91 percent) reported the existence of a process dedicated to evaluating innovative MDs; of these, 16 declared that their hospitals had a formalized unit with HB-HTA activity. These units were more frequently found in larger hospitals with more than 500 inpatient beds (n = 16, p = 0.0160) and in university hospitals (n = 12, p = 0.0158). No hospital reported any collaboration with HAS, the French national HTA agency. Conclusion: A diverse range of HB-HTA organizations with different structural levels exist in France for MD procurement linked to the category of hospitals. The study highlights the need for recognition of HB-HTA activity at the regulatory level in France and for direct collaboration between HTA activities performed at local and national levels.
- Open Access
- 4 October 2022
- Published by Springer Nature in CVIR Endovascular
- Vol. 5 (1) , 1-8
Safety and efficacy of the VenaTech™ Retrievable inferior vena cava filter: a first-in-man single-center prospective study
Background: Venous thromboembolism (VTE) is a frequent condition worldwide, associated with significant morbidity and mortality. Though its primary treatment is anticoagulation, the placement of an inferior vena cava (IVC) filter is recommended in patients with some comorbidities. The objectives of this study were to evaluate the clinical safety and efficacy of the Venatech® retrievable IVC filter. This open-label prospective single-center study was conducted on 40 consecutive patients requiring temporary or permanent IVC filtration. Patient characteristics, technical success rates of filter placement and removal, and the occurrence of complications were assessed. Follow-up imaging was performed using CT-scan before retrieval or at 6 months in the permanent indication population. Results: The filter was successfully implanted at the intended location in all the patients. Retrieval was attempted in 21 (52.5%) patients after a mean period of 50 days (range: 6–94 days), and the filter was successfully removed in 18 patients (85.7%). Reason for retrieval failure was filter with trapped thrombus (n = 2) and a > 15° tilt (n = 1). No complication was observed during the filter placement and retrieval. Follow-up imaging available in 30 patients (75%) demonstrated deep filter penetration (> 3 mm) in four patients (13.3%), severe filter tilt (> 15o) in five patients (16.7%), filter with trapped thrombus in three patients (10%), but no fracture or IVC thrombosis. Conclusion: This prospective study showed encouraging preliminary results of the safety and efficacy of the Venatech® retrievable IVC filter. The filter was easily delivered in the intended position and successfully removed in a high percentage of patients. Trial registration: ClinicalTrials.gov Identifier: NCT02674672
- 4 October 2022
- Published by Springer Nature in CVIR Endovascular
- Vol. 5 (1) , 1-8
Open AccessSafety and efficacy of the VenaTech™ Retrievable inferior vena cava filter: a first-in-man single-center prospective study
Background: Venous thromboembolism (VTE) is a frequent condition worldwide, associated with significant morbidity and mortality. Though its primary treatment is anticoagulation, the placement of an inferior vena cava (IVC) filter is recommended in patients with some comorbidities. The objectives of this study were to evaluate the clinical safety and efficacy of the Venatech® retrievable IVC filter. This open-label prospective single-center study was conducted on 40 consecutive patients requiring temporary or permanent IVC filtration. Patient characteristics, technical success rates of filter placement and removal, and the occurrence of complications were assessed. Follow-up imaging was performed using CT-scan before retrieval or at 6 months in the permanent indication population. Results: The filter was successfully implanted at the intended location in all the patients. Retrieval was attempted in 21 (52.5%) patients after a mean period of 50 days (range: 6–94 days), and the filter was successfully removed in 18 patients (85.7%). Reason for retrieval failure was filter with trapped thrombus (n = 2) and a > 15° tilt (n = 1). No complication was observed during the filter placement and retrieval. Follow-up imaging available in 30 patients (75%) demonstrated deep filter penetration (> 3 mm) in four patients (13.3%), severe filter tilt (> 15o) in five patients (16.7%), filter with trapped thrombus in three patients (10%), but no fracture or IVC thrombosis. Conclusion: This prospective study showed encouraging preliminary results of the safety and efficacy of the Venatech® retrievable IVC filter. The filter was easily delivered in the intended position and successfully removed in a high percentage of patients. Trial registration: ClinicalTrials.gov Identifier: NCT02674672
- 9 December 2021
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 80 (4) , 519-530
Les thérapies digitales : quels freins pour leur prise en charge ?
- 9 December 2021
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 80 (4) , 519-530
Les thérapies digitales : quels freins pour leur prise en charge ?