Sydney Shoulder Research Institute
Type
EducationLocations
St Leonards, AustraliaRelationships
Latest Publications
- 20 November 2026
- Published by SAGE Publications in Shoulder & Elbow
The ‘Lower-Trap-Door’ technique: Inlay trapezoidal Achilles bone-block fixation for lower trapezius tendon transfer
Purpose: To describe a novel inlay bone-to-bone fixation technique for lower trapezius tendon (LTT) transfer using a trapezoidal humeral osteotomy and Achilles tendon–bone allograft. Methods: The Lower-Trap-Door technique incorporates a wedge-shaped calcaneal bone block into a hinged trapezoidal osteotomy at the greater tuberosity. The bone block is press-fitted within the osteotomy and secured using double-row suture anchor fixation. The design creates intrinsic mechanical stability through bone-to-bone contact prior to suture compression. The technique allows integration with superior capsular reconstruction (SCR) when indicated. Results: This Technical Note details the indications, surgical setup, graft preparation, humeral osteotomy, bone-block insertion, double-row fixation, optional integration with SCR, postoperative rehabilitation, technical pearls, and potential complications. The technique has been used by the senior author in more than 15 patients, with no observed failures at the humeral bone-block interface to date. Formal clinical outcome data are not presented. Conclusion: The Lower-Trap-Door technique provides an inlay bone-to-bone fixation method for LTT transfer using a trapezoidal humeral osteotomy and Achilles tendon–bone allograft. Early clinical use suggests feasibility and construct reliability at the bone-block interface, although formal biomechanical testing and prospective clinical outcome studies are required to validate its comparative effectiveness.
- 20 November 2026
- Published by SAGE Publications in Shoulder & Elbow
The ‘Lower-Trap-Door’ technique: Inlay trapezoidal Achilles bone-block fixation for lower trapezius tendon transfer
Purpose: To describe a novel inlay bone-to-bone fixation technique for lower trapezius tendon (LTT) transfer using a trapezoidal humeral osteotomy and Achilles tendon–bone allograft. Methods: The Lower-Trap-Door technique incorporates a wedge-shaped calcaneal bone block into a hinged trapezoidal osteotomy at the greater tuberosity. The bone block is press-fitted within the osteotomy and secured using double-row suture anchor fixation. The design creates intrinsic mechanical stability through bone-to-bone contact prior to suture compression. The technique allows integration with superior capsular reconstruction (SCR) when indicated. Results: This Technical Note details the indications, surgical setup, graft preparation, humeral osteotomy, bone-block insertion, double-row fixation, optional integration with SCR, postoperative rehabilitation, technical pearls, and potential complications. The technique has been used by the senior author in more than 15 patients, with no observed failures at the humeral bone-block interface to date. Formal clinical outcome data are not presented. Conclusion: The Lower-Trap-Door technique provides an inlay bone-to-bone fixation method for LTT transfer using a trapezoidal humeral osteotomy and Achilles tendon–bone allograft. Early clinical use suggests feasibility and construct reliability at the bone-block interface, although formal biomechanical testing and prospective clinical outcome studies are required to validate its comparative effectiveness.
- Open Access
- 25 September 2026
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 8 (5) , e70083
Suture Slippage Is Influenced by Suture Type and Bone Density in a Knotless Lateral Row Rotator Cuff Repair: A Biomechanical Analysis
Purpose: To evaluate the influence of suture material and bone density on suture slippage in knotless lateral row anchors used in rotator cuff repair. Methods: Analysis of 3 different suture materials loaded into a single lateral row anchor and tested in 2 different densities (osteoporotic and normal) of Sawbone models was conducted. Testing was carried out using perpendicular traction of loaded sutures in a load cell with assessment of maximum force (N) and displacement (mm). After testing completion, the blocks were visually analyzed, and cut‐through length (mm) was measured. Results: Suture type ( P < .001) and bone density ( P < .001) have a significant effect on maximum force tolerance by the construct. FiberTape can withstand a much higher maximum force irrespective of bone densities. Displacement data collected from the load cell shows that suture type ( P < .001), but not bone density ( P = .228), plays a significant role, with FiberTape having a comparatively lower displacement. Evaluation of cut‐through data shows that bone density ( P = .006), but not suture type ( P = .94), has a significant effect on cut‐through. Conclusions: Suture slippage in knotless lateral row fixation is significantly influenced by the suture material and the underlying bone density. Constructs using high‐strength suture tape showed higher load‐to‐failure and lower displacement compared with conventional sutures. Clinical Relevance: Our study shows that the weakest link in a knotless repair is the lateral row, and this can be influenced by the type of suture used in the construct along with the density of bone.
- 25 September 2026
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 8 (5) , e70083
Open AccessSuture Slippage Is Influenced by Suture Type and Bone Density in a Knotless Lateral Row Rotator Cuff Repair: A Biomechanical Analysis
Purpose: To evaluate the influence of suture material and bone density on suture slippage in knotless lateral row anchors used in rotator cuff repair. Methods: Analysis of 3 different suture materials loaded into a single lateral row anchor and tested in 2 different densities (osteoporotic and normal) of Sawbone models was conducted. Testing was carried out using perpendicular traction of loaded sutures in a load cell with assessment of maximum force (N) and displacement (mm). After testing completion, the blocks were visually analyzed, and cut‐through length (mm) was measured. Results: Suture type ( P < .001) and bone density ( P < .001) have a significant effect on maximum force tolerance by the construct. FiberTape can withstand a much higher maximum force irrespective of bone densities. Displacement data collected from the load cell shows that suture type ( P < .001), but not bone density ( P = .228), plays a significant role, with FiberTape having a comparatively lower displacement. Evaluation of cut‐through data shows that bone density ( P = .006), but not suture type ( P = .94), has a significant effect on cut‐through. Conclusions: Suture slippage in knotless lateral row fixation is significantly influenced by the suture material and the underlying bone density. Constructs using high‐strength suture tape showed higher load‐to‐failure and lower displacement compared with conventional sutures. Clinical Relevance: Our study shows that the weakest link in a knotless repair is the lateral row, and this can be influenced by the type of suture used in the construct along with the density of bone.
- Open Access
- 2 September 2026
- Published by Elsevier in European Journal of Radiology
- Vol. 205, 113206
Gaussian mixture modelling enables valid intramuscular fat quantification on T2- and intermediate-weighted shoulder MRI relative to two-point Dixon
- 2 September 2026
- Published by Elsevier in European Journal of Radiology
- Vol. 205, 113206
Open AccessGaussian mixture modelling enables valid intramuscular fat quantification on T2- and intermediate-weighted shoulder MRI relative to two-point Dixon
- Open Access
- 6 August 2026
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (4) , 100845
Modified pectoralis major transfer: a single-incision technique for scapular winging
- 6 August 2026
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (4) , 100845
Open AccessModified pectoralis major transfer: a single-incision technique for scapular winging
- 5 February 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (9) , 2224-2238
Developing a three-dimensional convolutional neural network for automated full-volume multi-tissue segmentation of the shoulder with comparisons to Goutallier classification and partial volume muscle quality analysis
- 5 February 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (9) , 2224-2238
Developing a three-dimensional convolutional neural network for automated full-volume multi-tissue segmentation of the shoulder with comparisons to Goutallier classification and partial volume muscle quality analysis
- Open Access
- 23 January 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 5 (2) , 154-159
Independent third row augmentation of massive rotator cuff repairs: surgical technique with radiological and patient outcomes
- 23 January 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 5 (2) , 154-159
Open AccessIndependent third row augmentation of massive rotator cuff repairs: surgical technique with radiological and patient outcomes
- Open Access
- 25 September 2024
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 17 (5) , 625-630
ChatGPT provides acceptable responses to patient questions regarding common shoulder pathology
Background: ChatGPT is rapidly becoming a source of medical knowledge for patients. This study aims to assess the completeness and accuracy of ChatGPT's answers to the most frequently asked patients’ questions about shoulder pathology. Methods: ChatGPT (version 3.5) was queried to produce the five most common shoulder pathologies: biceps tendonitis, rotator cuff tears, shoulder arthritis, shoulder dislocation and adhesive capsulitis. Subsequently, it generated the five most common patient questions regarding these pathologies and was queried to respond. Responses were evaluated by three shoulder and elbow fellowship-trained orthopedic surgeons with a mean of 9 years of independent practice, on Likert scales for accuracy (1–6) and completeness (rated 1–3). Results: For all questions, responses were deemed acceptable, rated at least “nearly all correct,” indicated by a score of 5 or greater for accuracy, and “adequately complete,” indicated by a minimum of 2 for completeness. The mean scores for accuracy and completeness, respectively, were 5.5 and 2.6 for rotator cuff tears, 5.8 and 2.7 for shoulder arthritis, 5.5 and 2.3 for shoulder dislocations, 5.1 and 2.4 for adhesive capsulitis, 5.8 and 2.9 for biceps tendonitis. Conclusion: ChatGPT provides both accurate and complete responses to the most common patients’ questions about shoulder pathology. These findings suggest that Large Language Models might play a role as a patient resource; however, patients should always verify online information with their physician. Level of Evidence: Level V Expert Opinion.
- 25 September 2024
- Published by SAGE Publications in Shoulder & Elbow
- Vol. 17 (5) , 625-630
Open AccessChatGPT provides acceptable responses to patient questions regarding common shoulder pathology
Background: ChatGPT is rapidly becoming a source of medical knowledge for patients. This study aims to assess the completeness and accuracy of ChatGPT's answers to the most frequently asked patients’ questions about shoulder pathology. Methods: ChatGPT (version 3.5) was queried to produce the five most common shoulder pathologies: biceps tendonitis, rotator cuff tears, shoulder arthritis, shoulder dislocation and adhesive capsulitis. Subsequently, it generated the five most common patient questions regarding these pathologies and was queried to respond. Responses were evaluated by three shoulder and elbow fellowship-trained orthopedic surgeons with a mean of 9 years of independent practice, on Likert scales for accuracy (1–6) and completeness (rated 1–3). Results: For all questions, responses were deemed acceptable, rated at least “nearly all correct,” indicated by a score of 5 or greater for accuracy, and “adequately complete,” indicated by a minimum of 2 for completeness. The mean scores for accuracy and completeness, respectively, were 5.5 and 2.6 for rotator cuff tears, 5.8 and 2.7 for shoulder arthritis, 5.5 and 2.3 for shoulder dislocations, 5.1 and 2.4 for adhesive capsulitis, 5.8 and 2.9 for biceps tendonitis. Conclusion: ChatGPT provides both accurate and complete responses to the most common patients’ questions about shoulder pathology. These findings suggest that Large Language Models might play a role as a patient resource; however, patients should always verify online information with their physician. Level of Evidence: Level V Expert Opinion.
- Open Access
- 27 June 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (12) , e641-e651
Medial scapular body (MSB) Goutallier classification: MRI-based reliability and validity of evaluation of the Goutallier classification for grading fatty infiltration of the rotator cuff
- 27 June 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (12) , e641-e651
Open AccessMedial scapular body (MSB) Goutallier classification: MRI-based reliability and validity of evaluation of the Goutallier classification for grading fatty infiltration of the rotator cuff
- 23 March 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (8) , 1699-1708
Midterm follow-up of the Nexel total elbow arthroplasty
- 23 March 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (8) , 1699-1708
Midterm follow-up of the Nexel total elbow arthroplasty