State Grid Chongqing Electric Power Company (China)
Types
Company, FunderLocations
Chongqing, ChinaRelationships
Latest Publications
- Open Access
Online Diagnosis of Transformer Winding Deformation Using Fault-Recorder Data
Power transformers are critical components in transmission and distribution systems, and their operational condition is paramount to grid safety and stability. Current transformer winding monitoring methods, due to their need for extra sensors or signal injection, fail to meet new intelligent power grid’s true online monitoring demand. To address the limitations of invasive monitoring, this paper proposes a non-invasive diagnostic framework utilizing substation fault-recorded waveform data and a hybrid neural network. The model integrates Squeeze-and-Excitation (SE), Bidirectional Gated Recurrent Unit (BiGRU), and ProbSparse Attention (PA) mechanisms. The approach extracts port ΔU-I signals to reconstruct Lissajous figures, applying a preprocessing pipeline of wavelet denoising and load normalization to ensure feature stability under operational fluctuations. To ensure robust training, an 800-sample hybrid dataset was established by combining field-circuit simulations in Ansys Electronics Desktop 2022 R1 with 10 kV experimental tests to cover diverse fault types and realistic interference. Results show the model achieves a diagnostic accuracy of 97.5%, significantly outperforming traditional architectures. The practical feasibility was further validated through two engineering examples, where diagnostic outcomes perfectly aligned with actual field maintenance reports.
Open AccessOnline Diagnosis of Transformer Winding Deformation Using Fault-Recorder Data
Power transformers are critical components in transmission and distribution systems, and their operational condition is paramount to grid safety and stability. Current transformer winding monitoring methods, due to their need for extra sensors or signal injection, fail to meet new intelligent power grid’s true online monitoring demand. To address the limitations of invasive monitoring, this paper proposes a non-invasive diagnostic framework utilizing substation fault-recorded waveform data and a hybrid neural network. The model integrates Squeeze-and-Excitation (SE), Bidirectional Gated Recurrent Unit (BiGRU), and ProbSparse Attention (PA) mechanisms. The approach extracts port ΔU-I signals to reconstruct Lissajous figures, applying a preprocessing pipeline of wavelet denoising and load normalization to ensure feature stability under operational fluctuations. To ensure robust training, an 800-sample hybrid dataset was established by combining field-circuit simulations in Ansys Electronics Desktop 2022 R1 with 10 kV experimental tests to cover diverse fault types and realistic interference. Results show the model achieves a diagnostic accuracy of 97.5%, significantly outperforming traditional architectures. The practical feasibility was further validated through two engineering examples, where diagnostic outcomes perfectly aligned with actual field maintenance reports.
- Open Access
- 9 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4595
Electromechanical and Structural Loading Effects of Virtual Synchronous Generator Control in Doubly Fed Induction Generator Wind Turbines
Virtual synchronous generator (VSG) control changes electromagnetic torque in doubly fed induction generator (DFIG) wind turbines and can redistribute structural loading. This study couples Fatigue, Aerodynamics, Structures, and Turbulence (FAST) v8.16 with MATLAB/Simulink to compare vector control and VSG control with current-aligned protection. A six-unit electrical equivalent is coupled to one flexible WindPACT 1.5 MW turbine through consistent coordinate, speed, torque, and power-base mappings. Load-step responses illustrate transient electromechanical coupling, and three paired turbulent realizations at a nominal wind speed of 9 m/s quantify short-term fatigue loading. The 1 Hz damage-equivalent loads (DELs) are evaluated over 60–120 s using unbinned rainflow counting without mean-stress correction. Relative to vector control, VSG changes the mean DEL by −4.43% for tower fore–aft, −0.06% for tower side-to-side, +24.76% for drivetrain torque, +1.88% for blade flapwise, and −0.67% for blade edgewise loading. Numerical-resolution and initial-state checks show that the smaller differences require cautious interpretation. The results identify a trade-off between tower fore–aft and drivetrain loading for complete control implementations under the evaluated conditions.
- 9 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (20) , 4595
Open AccessElectromechanical and Structural Loading Effects of Virtual Synchronous Generator Control in Doubly Fed Induction Generator Wind Turbines
Virtual synchronous generator (VSG) control changes electromagnetic torque in doubly fed induction generator (DFIG) wind turbines and can redistribute structural loading. This study couples Fatigue, Aerodynamics, Structures, and Turbulence (FAST) v8.16 with MATLAB/Simulink to compare vector control and VSG control with current-aligned protection. A six-unit electrical equivalent is coupled to one flexible WindPACT 1.5 MW turbine through consistent coordinate, speed, torque, and power-base mappings. Load-step responses illustrate transient electromechanical coupling, and three paired turbulent realizations at a nominal wind speed of 9 m/s quantify short-term fatigue loading. The 1 Hz damage-equivalent loads (DELs) are evaluated over 60–120 s using unbinned rainflow counting without mean-stress correction. Relative to vector control, VSG changes the mean DEL by −4.43% for tower fore–aft, −0.06% for tower side-to-side, +24.76% for drivetrain torque, +1.88% for blade flapwise, and −0.67% for blade edgewise loading. Numerical-resolution and initial-state checks show that the smaller differences require cautious interpretation. The results identify a trade-off between tower fore–aft and drivetrain loading for complete control implementations under the evaluated conditions.
- 21 September 2026
- Published by Emerald Publishing in Microelectronics International
- p. 1-14
Energy management control of grid-tied PV-battery system based on intelligent proportional allocation
Purpose: Most existing grid-tied PV-battery systems rely on static charge-discharge schedules, typically involving daytime battery charging and nighttime discharging, which lead to inefficient energy storage utilization and reduced overall economic performance. Traditional energy management techniques, primarily designed in large timescales, are hard to deal with the rapid and stochastic fluctuations of PV-battery systems, which reduces the modeling accuracy and economic efficiency of system operation. Furthermore, conventional centralized or hierarchical optimization frameworks often overlook the control requirements of underlying power converters, which makes it challenging to simultaneously achieve both high economic efficiency and operational stability. This paper aims to improve the economic efficiency and operational stability of PV-battery systems considering the control requirements of power converters. Design/methodology/approach: A novel energy management control strategy for grid-tied PV-battery systems is proposed, structured within a dual-layer architecture that integrates upper-layer intelligent optimization scheduling with lower-layer proportional coordinated converter control. Specifically, a robust optimization-based multi-timescale scheduling framework is formulated, integrating day-ahead and intraday scheduling to effectively mitigate system uncertainties and improve economic performance. On this basis, an optimized proportional allocation-based control strategy is proposed at the converter level. Findings: This method ensures precise tracking of upper-layer dispatch commands while substantially enhancing dynamic response and operational stability of the system. The correctness of the theories has been verified by simulations and experiments. Originality/value: To address the current challenges of insufficient robustness in master–slave control and limited accuracy in droop control, a new converter cooperative control method is needed that balances command tracking precision with operational robustness. This paper therefore investigates two levels, i.e. scheduling and control. At the scheduling level, a multi-timescale optimization model combining two-stage robust optimization with intraday rolling correction is developed to accommodate highly volatile operating scenarios. At the control level, an optimized proportional allocation strategy for energy management control is proposed to enhance system dynamic stability. Finally, simulations and experiments validate the effectiveness of the proposed method.
- 21 September 2026
- Published by Emerald Publishing in Microelectronics International
- p. 1-14
Energy management control of grid-tied PV-battery system based on intelligent proportional allocation
Purpose: Most existing grid-tied PV-battery systems rely on static charge-discharge schedules, typically involving daytime battery charging and nighttime discharging, which lead to inefficient energy storage utilization and reduced overall economic performance. Traditional energy management techniques, primarily designed in large timescales, are hard to deal with the rapid and stochastic fluctuations of PV-battery systems, which reduces the modeling accuracy and economic efficiency of system operation. Furthermore, conventional centralized or hierarchical optimization frameworks often overlook the control requirements of underlying power converters, which makes it challenging to simultaneously achieve both high economic efficiency and operational stability. This paper aims to improve the economic efficiency and operational stability of PV-battery systems considering the control requirements of power converters. Design/methodology/approach: A novel energy management control strategy for grid-tied PV-battery systems is proposed, structured within a dual-layer architecture that integrates upper-layer intelligent optimization scheduling with lower-layer proportional coordinated converter control. Specifically, a robust optimization-based multi-timescale scheduling framework is formulated, integrating day-ahead and intraday scheduling to effectively mitigate system uncertainties and improve economic performance. On this basis, an optimized proportional allocation-based control strategy is proposed at the converter level. Findings: This method ensures precise tracking of upper-layer dispatch commands while substantially enhancing dynamic response and operational stability of the system. The correctness of the theories has been verified by simulations and experiments. Originality/value: To address the current challenges of insufficient robustness in master–slave control and limited accuracy in droop control, a new converter cooperative control method is needed that balances command tracking precision with operational robustness. This paper therefore investigates two levels, i.e. scheduling and control. At the scheduling level, a multi-timescale optimization model combining two-stage robust optimization with intraday rolling correction is developed to accommodate highly volatile operating scenarios. At the control level, an optimized proportional allocation strategy for energy management control is proposed to enhance system dynamic stability. Finally, simulations and experiments validate the effectiveness of the proposed method.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 770-773
Analysis of Electric Energy Reconciliation Under Current Loss Faults of Smart Meters
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 770-773
Analysis of Electric Energy Reconciliation Under Current Loss Faults of Smart Meters
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 774-778
Cause Analysis of Metering Anomalies in Smart Energy Meters Under Reverse Phase- Sequence Conditions
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 774-778
Cause Analysis of Metering Anomalies in Smart Energy Meters Under Reverse Phase- Sequence Conditions
- Open Access
A Two-Stage Stochastic Programming Model for Proactive Scheduling of Distribution Networks with Emergency Resource Participation
By implementing a proactive reserve scheduling mechanism, distribution networks (DNs) can optimize emergency resource deployment to improve fault recovery resilience. To address the limitations of existing pre-disaster preparation strategies that only consider limited resources, this paper proposes a proactive scheduling strategy that integrates mobile resources and field personnel in a coordinated manner for DNs. By establishing a two-stage stochastic mixed-integer programming (SMIP) model for coordinated control of emergency resources in DNs, the first stage determines the quantity and location of mobile energy storage systems (MESSs), repair crews (RCs), and switching crews (SCs). In the second stage, the emergency resources rapidly reach the affected sites to participate in sequential restoration of the DN. Finally, the model is validated using standard IEEE test systems. The results from the experiments demonstrate that the proposed method reduces load shedding cost by 19.0% and 19.9% on 33-node and 123-node systems. Empirical simulations confirm that the introduced framework enables efficient emergency resource orchestration, thereby enhancing the pre-disaster preventive response capability and post-disaster real-time restoration capability of the DN, significantly mitigating the impact of disruptive events.
Open AccessA Two-Stage Stochastic Programming Model for Proactive Scheduling of Distribution Networks with Emergency Resource Participation
By implementing a proactive reserve scheduling mechanism, distribution networks (DNs) can optimize emergency resource deployment to improve fault recovery resilience. To address the limitations of existing pre-disaster preparation strategies that only consider limited resources, this paper proposes a proactive scheduling strategy that integrates mobile resources and field personnel in a coordinated manner for DNs. By establishing a two-stage stochastic mixed-integer programming (SMIP) model for coordinated control of emergency resources in DNs, the first stage determines the quantity and location of mobile energy storage systems (MESSs), repair crews (RCs), and switching crews (SCs). In the second stage, the emergency resources rapidly reach the affected sites to participate in sequential restoration of the DN. Finally, the model is validated using standard IEEE test systems. The results from the experiments demonstrate that the proposed method reduces load shedding cost by 19.0% and 19.9% on 33-node and 123-node systems. Empirical simulations confirm that the introduced framework enables efficient emergency resource orchestration, thereby enhancing the pre-disaster preventive response capability and post-disaster real-time restoration capability of the DN, significantly mitigating the impact of disruptive events.
- Open Access
- 29 August 2026
- Published by Oxford University Press (OUP) in Clean Energy
LLM-Enabled Cloud-Edge PIoT for Low-Carbon Energy Services: A Review of Virtual Power Plants, Digital Twins, and Demand Response
Low-carbon smart energy systems increasingly rely on dense sensing, distributed energy resources, virtual power plants, digital twins and demand response. These services require cloud-edge intelligence, but practical deployment is constrained by latency, reliability, privacy, cybersecurity and the energy and carbon cost of computation. This review examines how large language models can be introduced into the power internet of things without shifting them into the role of direct grid control agents. The literature is organised around five technical themes: task offloading, dynamic edge resource allocation, low-latency communication and collaborative computing, security and privacy protection, and green computing. The review then evaluates intelligent inspection, digital-twin assistance, virtual power plants, demand response, and load forecasting through an explicit evidence-maturity hierarchy. Across the reviewed studies, the most practical deployment pattern places large language models between heterogeneous operational evidence and verified engineering tools. Language models can organise evidence, invoke approved tools, and assist operator judgement; authority over physical control and market execution remains with deterministic models. Claims of low-carbon benefit should be based on the joint assessment of service performance, reliability, security, energy consumption, and carbon emissions.
- 29 August 2026
- Published by Oxford University Press (OUP) in Clean Energy
Open AccessLLM-Enabled Cloud-Edge PIoT for Low-Carbon Energy Services: A Review of Virtual Power Plants, Digital Twins, and Demand Response
Low-carbon smart energy systems increasingly rely on dense sensing, distributed energy resources, virtual power plants, digital twins and demand response. These services require cloud-edge intelligence, but practical deployment is constrained by latency, reliability, privacy, cybersecurity and the energy and carbon cost of computation. This review examines how large language models can be introduced into the power internet of things without shifting them into the role of direct grid control agents. The literature is organised around five technical themes: task offloading, dynamic edge resource allocation, low-latency communication and collaborative computing, security and privacy protection, and green computing. The review then evaluates intelligent inspection, digital-twin assistance, virtual power plants, demand response, and load forecasting through an explicit evidence-maturity hierarchy. Across the reviewed studies, the most practical deployment pattern places large language models between heterogeneous operational evidence and verified engineering tools. Language models can organise evidence, invoke approved tools, and assist operator judgement; authority over physical control and market execution remains with deterministic models. Claims of low-carbon benefit should be based on the joint assessment of service performance, reliability, security, energy consumption, and carbon emissions.