Type
Healthcare
Locations
Ōdate, Japan
Relationships

Latest Publications

  • Open Access

    Osteochondritis dissecans of the glenoid in a 13-year-old baseball player: A case report

    by Nobutoshi Seki, Koichiro Okuyama, Keiji Kamo, Naohisa Miyakoshi, Yoichi Shimada


  • Effect of an Anterior Glenoid Defect on Anterior Shoulder Stability

    by Nobuyuki Yamamoto, Eiji Itoi, Hidekazu Abe, Kazuma Kikuchi, Nobutoshi Seki, Hiroshi Minagawa, Yilihamu Tuoheti

    Background: There have been few biomechanical studies to clarify which size of a glenoid defect is critical. However, those studies have assumed that the defect occurred anteroinferiorly. Recent studies have reported that the defect is located anteriorly rather than anteroinferiorly. Therefore, the effect of the anterior, not anteroinferior, glenoid defect on shoulder stability needs to be investigated. Hypothesis: The anterior glenoid defect would have a similar effect on anterior shoulder stability as that of the anteroinferior glenoid defect. Study Design: Controlled laboratory study. Methods: Eight fresh-frozen cadaveric shoulders were used (mean age, 74 years). The specimen was attached to a shoulder-testing device with the arm in abduction and external rotation. An osseous defect was created stepwise with a 2-mm increment of the defect width. The stability ratio was used to evaluate joint stability. With a 50-N axial force, the translational force applied to the humeral head was measured by a force transducer. Results: The stability ratio without a defect (32% ± 6%) significantly decreased after creating a 6-mm defect (17% ± 5%; P = .0001), which was equivalent to 20% of the glenoid length. Conclusion: An osseous defect at 3 o'clock with a width that was equal to or greater than 20% of the glenoid length significantly decreased anterior stability. Clinical Relevance: The results suggest that reconstruction of the glenoid concavity might be necessary in shoulders with an anterior glenoid defect of at least 20% of the glenoid length.


  • Influence of bone mineral density on pedicle screw fixation

    by Koichiro Okuyama, Eiji Abe, Tetsuya Suzuki, Yasuki Tamura, Mitzuho Chiba, Kozo Sato


  • Can Insertional Torque Predict Screw Loosening and Related Failures?

    by Koichiro Okuyama, Eiji Abe, Tetsuya Suzuki, Yasuki Tamura, Mitzuho Chiba, Kozo Sato

    Study Design. An investigation of the relation between intraoperative insertional torque of pedicle screws, bone mineral density of the vertebra, and development of screw loosening in vivo. Objectives. To determine the usefulness of intraoperative measurement of the insertional torque of pedicle screws. Summary of Background Data. Some biomechanical studies have demonstrated that the insertional torque is highly correlated with bone mineral density and the stability of pedicle screws in vitro. Methods. Pedicle screw fixation was performed with posterior lumbar interbody fusion in 62 consecutive patients. The mean age of the patients at the time of surgery was 58 years. The insertional torque of pedicle screws was measured intraoperatively in all patients. The mean follow-up period was 2.7 years. Results. The mean insertional torque was 1.28 ± 0.37 Nm in patients with screw loosening and 1.50 ± 0.40 Nm in patients without the problem. The mean insertional torque in patients with compression fractures in the upper vertebra adjacent to the fixed segment was 0.83 ± 0.23 Nm. There was no significant difference between the mean insertional torque in patients with screw loosening and those without the condition. The mean insertional torque in patients without screw loosening was significantly greater than in patients with compression fractures (P < 0.01). A high correlation was found between insertional torque and bone mineral density (P < 0.01). Conclusions. Although a high correlation was found between the insertional torque of pedicle screws andbone mineral density in vivo, the insertional torque could not objectively predict screw loosening.