Type
Company
Locations
Bengaluru, India
Relationships
Parent Organizations

Latest Publications

  • Open Access

    Twelve-Months Follow-Up Postmarket Study of a Hydrophobic Intraocular Lens Using a Preloaded Automated Injector in an Indian Population

    by Jeewan S Titiyal, Samar K Basak, Naren Shetty, Umang Mathur, Prema Padmanabhan, Sri Ganesh, Arindam Dey, Dandapani Ramamurthy

    Purpose: To assess real-world clinical outcomes and safety of the Clareon® intraocular lens (IOL) and AutonoMe® automated preloaded delivery system in an Indian population. Patients and methods: This was a prospective, single-arm, multicenter, 12-month clinical study in patients aged ≥ 20 years with unilateral or bilateral cataracts. Surgery was performed by phacoemulsification followed by implantation of the Clareon monofocal IOL (CNA0T0). Monocular best-corrected distance visual acuity (BCDVA) and uncorrected distance visual acuity (UCDVA) were assessed at 1 week and 1, 6, and 12 months after implantation. Posterior capsular opacification (PCO), surface haze, and glistenings were evaluated at all visits. Surgeons’ satisfaction with automated injector system was also evaluated using a questionnaire. Safety was assessed by monitoring adverse events (AEs). Results: A total of 151 eyes received the CNA0T0 IOL. Mean ± SD monocular BCDVA improved from 0.53± 0.44 logMAR preoperatively to 0.00± 0.08 logMAR at week 1 and − 0.03± 0.08 logMAR at 12 months after implantation. At 12 months, 137/137 (100%) of eyes achieved BCDVA of 0.3 logMAR or better. Mean ± SD monocular UCDVA was 0.78± 0.40 logMAR preoperatively, 0.11± 0.15 logMAR at week 1, and 0.08± 0.13 logMAR at 12 months after implantation. At 12 months, 132/137 (96%) eyes achieved UCDVA of 0.3 logMAR or better. Serious intraoperative AEs were posterior capsule rupture (n=1) and ciliary zonular dehiscence (n=1). Surgeons reported that the automated preloaded device was more intuitive compared with other push- or screw-style preloaded injector systems. None of the eyes in this study presented surface haze; all were graded as 0 glistenings at all visits. No clinically significant PCO or neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomies were reported. Conclusion: The hydrophobic IOL preloaded in an automated injector system provided good visual and refractive outcomes, as well as no surface haze and grade 0 glistenings. None of the patients required Nd:YAG capsulotomy.


  • Open Access

    Training Indian ophthalmologists in phacoemulsification surgery: Nine-year results of a unique two-week multicentric training program

    by Javed Hussain Farooqui, Umang Mathur, Rashmi Rani Pahwa, Aditi Singh, Vaishali Vasavada, Reena M Chaudhary, Phaco Development Program Working Group

    Purpose: To assess the outcome of 2 weeks phacoemulsification training program that is a unique collaboration between premier ophthalmic training institutes of India and Alcon Inc. initiated 10 years ago. Methods: Cataract surgeons eager to adopt phacoemulsification surgery as the primary treatment modality were enrolled in an intensive 2 weeks training program across seven premier ophthalmic institutes in India. These surgeons performed supervised phacoemulsification surgery under the guidance of expert faculty. Simultaneously didactic lectures, postoperative video discussions, and wet laboratory training were conducted. To assess improvement in the surgical skills each surgery was scored using the International Council of Ophthalmology-Ophthalmology Surgical Competency Assessment Rubrics (ICO-OSCAR). Phaco Development Specialist supported these surgeons for minimum duration of 1 year and maximum of 9 years and 2 months. In this multicentric study, surgical data of the participants enrolled between June 2010 to August 2018 was retrospectively analyzed. Results: Nine hundred 89 ophthalmologists across 27 Indian states and 4 Union Territories were trained between June 2010 and August 2018. The mean age of participants was 40.6 (+ 8.2 years) and 64.8% were males. After completing their training they performed 1,022,508 phacoemulsification surgeries in 9 years and 2 months. At follow-up, 92.11% and 88.77% of the surgeons were performing phacoemulsification at the end of 1 year and final follow-up, respectively. Conclusion: This program highlights how partnership model between industry and ophthalmologists can go hand in hand for training and skill development of doctors contributing to much-needed improvement in patient care across societies.


  • Open Access

    Clinical Outcomes After Bilateral Implantation of a Trifocal Presbyopia-Correcting Intraocular Lens in an Indian Population

    by Dandapani Ramamurthy, Abhay Vasavada, Prema Padmanabhan, Jagadesh C Reddy, Naren Shetty, Arindam Dey, Rachapalle Reddi Sudhir

    Purpose: To evaluate the effectiveness and safety of a presbyopia-correcting trifocal intraocular lens (IOL), AcrySof® IQ PanOptix® (TFNT00), in an Indian population. Patients and Methods: This prospective, multicenter, observational, single-arm, post-marketing study included 67 patients undergoing cataract surgery with bilateral implantation of TFNT00 across five Indian sites. Postoperative outcomes were assessed at 3 months after second eye surgery. Effectiveness outcomes included: mean binocular and monocular visual acuity (VA) at distance (4 m), intermediate (60 cm), and near (40 cm); binocular defocus curve; manifest refraction; and subjective symptom questionnaire evaluation. Safety outcomes included the rate of ocular adverse events and mesopic contrast sensitivity. Results: Mean binocular and monocular distance-corrected and uncorrected VAs of 0.1 logMAR or better (approximately 20/25 Snellen) were achieved at distance, intermediate, and near. Overall, ≥ 70% of patients achieved binocular 0.1 logMAR vision or better across all distances. TFNT00 maintained a mean VA of 0.1 logMAR or better at the defocus range of +0.5 diopters (D) to – 2.5 D (200 cm to 40 cm). The subjective symptom questionnaire-assessed frequency of halo visual disturbances was low at Month 3; halos were reported “none of the time” to “only some of the time” in 86.6% of patients. The large majority of patients (98.5%) were “satisfied” or “very satisfied” with their near, intermediate, and distance vision at Month 3, and ≥ 94.0% of patients reported spectacle independence for tasks at all distances. The adverse event rate was low; no patients discontinued due to an adverse event. Conclusion: TFNT00 provided a continuous range of vision of 20/25 or better for distance to near and performed effectively at an intermediate functional distance of 60 cm, resulting in high levels of spectacle independence and patient satisfaction. TFNT00 demonstrated a good safety profile and a low post-operative frequency of halo visual disturbances.