Twelve-Months Follow-Up Postmarket Study of a Hydrophobic Intraocular Lens Using a Preloaded Automated Injector in an Indian Population
Open Access
- 16 December 2022
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 4215-4225
Abstract
Purpose: To assess real-world clinical outcomes and safety of the Clareon® intraocular lens (IOL) and AutonoMe® automated preloaded delivery system in an Indian population. Patients and methods: This was a prospective, single-arm, multicenter, 12-month clinical study in patients aged ≥ 20 years with unilateral or bilateral cataracts. Surgery was performed by phacoemulsification followed by implantation of the Clareon monofocal IOL (CNA0T0). Monocular best-corrected distance visual acuity (BCDVA) and uncorrected distance visual acuity (UCDVA) were assessed at 1 week and 1, 6, and 12 months after implantation. Posterior capsular opacification (PCO), surface haze, and glistenings were evaluated at all visits. Surgeons’ satisfaction with automated injector system was also evaluated using a questionnaire. Safety was assessed by monitoring adverse events (AEs). Results: A total of 151 eyes received the CNA0T0 IOL. Mean ± SD monocular BCDVA improved from 0.53± 0.44 logMAR preoperatively to 0.00± 0.08 logMAR at week 1 and − 0.03± 0.08 logMAR at 12 months after implantation. At 12 months, 137/137 (100%) of eyes achieved BCDVA of 0.3 logMAR or better. Mean ± SD monocular UCDVA was 0.78± 0.40 logMAR preoperatively, 0.11± 0.15 logMAR at week 1, and 0.08± 0.13 logMAR at 12 months after implantation. At 12 months, 132/137 (96%) eyes achieved UCDVA of 0.3 logMAR or better. Serious intraoperative AEs were posterior capsule rupture (n=1) and ciliary zonular dehiscence (n=1). Surgeons reported that the automated preloaded device was more intuitive compared with other push- or screw-style preloaded injector systems. None of the eyes in this study presented surface haze; all were graded as 0 glistenings at all visits. No clinically significant PCO or neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomies were reported. Conclusion: The hydrophobic IOL preloaded in an automated injector system provided good visual and refractive outcomes, as well as no surface haze and grade 0 glistenings. None of the patients required Nd:YAG capsulotomy.Keywords
This publication has 19 references indexed in Scilit:
- Klinische Erfahrung mit der Clareon®-IOL und dem AutonoMe®-ImplantationssystemDer Ophthalmologe, 2020
- Evaluation of clarity characteristics in a new hydrophobic acrylic IOL in comparison to commercially available IOLsJournal of Cataract & Refractive Surgery, 2019
- Surface properties of commercially available hydrophobic acrylic intraocular lenses: Comparative studyJournal of Cataract & Refractive Surgery, 2019
- In vivo and in vitro results of an automated preloaded delivery system for IOL implantation in cataract surgeryInternational Ophthalmology, 2019
- In vitro and schematic model eye assessment of glare or positive dysphotopsia-type photic phenomena: Comparison of a new material IOL to other monofocal IOLsJournal of Cataract & Refractive Surgery, 2019
- A meta-analysis of Nd:YAG capsulotomy rates for two hydrophobic intraocular lens materialsClinical Ophthalmology, 2018
- Global causes of blindness and distance vision impairment 1990–2020: a systematic review and meta-analysisThe Lancet Global Health, 2017
- Evidence-based guidelines for cataract surgery: Guidelines based on data in the European Registry of Quality Outcomes for Cataract and Refractive Surgery databaseJournal of Cataract & Refractive Surgery, 2012
- Analysis of intraocular lens surface properties with atomic force microscopyJournal of Cataract & Refractive Surgery, 2006
- Clinical and Experimental Observation of Glistening in Acrylic Intraocular LensesJapanese Journal of Ophthalmology, 2001