Type
Company
Locations
Findlay, United States

Latest Publications

  • Open Access

    Influence of Aggregate Properties and Binder Source on HMA Performance Within a Balanced Mix Design Framework

    by Anas A. Jamrah, Stormy R. Brewster, Cristian S. Clopotel, Lora C. Collins, Tana C. Anderson

  • Open Access

    N-Substituent Effects on Selectivity in Ni-Mediated Decarbonylation of N-Arylphthalimides

    by Grace K. Murphy, Rebekah C. Krupa, Jessica M. Hoover

    The nickel-catalyzed decarbonylation of imides and amides is a promising molecular editing strategy for generating C-C and C-N coupled structures commonly found in biologically active molecules. Despite their potential utility, there is limited understanding of the structural features that influence selectivity and catalytic efficiency in this class of reactions. We aim to understand and address this catalytic limitation through the isolation and study of well-defined reaction intermediates. Herein, we report the synthesis and characterization of 5-membered Ni II -metallacycles that are proposed to be key intermediates in the nickel-catalyzed decarbonylation reactions of N-arylphthalimides. Complexes derived from the direct decarbonylation of both N-phenyl and N-pyrrolylphthalimides were synthesized using both 4-dimethylaminopyridine and 2,2’-bipyridyl supporting ligands and demonstrated to be competent intermediates in Ni-catalyzed decarbonylation reactions. Moreover, comparison of their synthesis and reactivity revealed a striking influence of the N-aryl substituent in modulating the decarbonylation and CO reinsertion steps.

  • ARC Flash Anaysis for Electrification Projects How Far Upstream and Downstream Should be Re-Evaluated a Refinery Case Study

    by Tony Acayan, Jimmy Singh, Albert Marroquin, Varsha Rajpurohit, Sina Ghods

    This paper [1] will review the implementation and share lessons learned of an arc flash analysis study that was performed in support of a large infrastructure refinery project in Southern California. This paper is a follow-up to PCIC2024-5 paper titled “THE PATH TO DECARBONIZATION TROUGH ELECTRIFICATION, A REFINERY CASE STUDY AND LESSONS LEARNED” [2] Parra et al., 2024] presented in the General session in Orlando, FL. Because of the extensive modifications to the existing refinery facilities, short-circuit and arc-flash (AF) incident energy (IE) values were re-evaluated. This paper will review how far upstream and downstream the re-evaluation took place. The goal of this paper is to serve as a reference and refresher guide for protection engineers performing arc-flash analysis. The goal of arc-flash analysis is to ensure full compliance with the project criterion established with the latest standards and regulations. The arc flash levels identified in the study and NFPA 70E allow the facilities to classify the IE at various locations to help identify the proper personal protective equipment (PPE) rating to ensure personnel safety.

  • Open Access

    Comprehensive Integrated Simulation Methodology for Enabling Near-Zero Emission Heavy-Duty Vehicles

    by Andrea Strzelec, Madison Univ. Of Wisconsin, Mario Trujillo, Syed Wahiduzzaman, Santhosh Gundlapally, Josh Pihl, Todd Toops, Erik Koehler, Claude Pilger, Bruce Vernham, et al.

    This project developed and validated an integrated reduced-dimensional simulation methodology for a modern heavy-duty diesel engine and its aftertreatment system. The team built physics-based models for in-cylinder combustion, exhaust gas dynamics, DOC, DPF, SCR, and ASC behavior. The team also developed a high-fidelity model for urea-water solution (UWS) injection and decomposition. The team integrated the component models in GT-SUITE through a quasi-steady circuit splitter and validated the system against engine dynamometer experiments. The team then used the simulation tool to design an advanced aftertreatment configuration that adds a close-coupled SCR to the OEM architecture. The team demonstrated the configuration on an engine dynamometer with both degreened and oven-aged catalysts. Engine dynamometer testing at FEV with the model-designed close-coupled SCR (ccSCR) configuration reduced NOx emissions by 30 to 67 percent against the baseline production aftertreatment across the certification cycles (Cold and Hot FTP, RMC/SET, and the Low Load Cycle). The aged ccSCR retained NOx reduction performance even with a slight reduction in ammonia storage capacity. The integrated GT-SUITE platform predicted the demonstrated performance accurately and is now ready as a design-stage tool for future ultra-low NOx aftertreatment systems. On the spray modeling side, the team built a Volume-of-Fluid to Lagrangian-Eulerian (VoFLE) hybrid solver to interrogate the fidelity of conventional Lagrangian-Eulerian (LE) UWS spray models. The VoFLE work resolves the internal nozzle dynamics and the primary breakup of the UWS jet, then converts small unresolved structures into Lagrangian parcels for efficient transport. The team validated the underlying Volume-of-Fluid (VoF) solver against the experimental and DNS-class liquid jet in crossflow datasets of Sallam and Li-Soteriou. The team then compared VoFLE against two LE configurations on the same port-fuel injector geometry. The results show that conventional LE methods are qualitatively and quantitatively inaccurate for UWS sprays. The primary error is not the breakup model. The primary error is the inability of LE to resolve the internal nozzle flow and the resulting non-axisymmetric jet directionality. A tuned Rosin Rammler injection improves droplet size predictions but cannot recover the non-axisymmetric spray cloud. These findings inform the next generation of reduced-order aftertreatment models, including the Gamma Technologies neural-network-based SCR surrogate published in SAE Int. J. Engines. The project achieved all milestones in Budget Periods 1, 2, and 3, including the Y3-3 milestone on a model-optimized engine map and aftertreatment configuration and the project-goal Near-Zero Emissions Concept Demonstration. UW initiated a change in approach for the Fuel Effects on Aftertreatment task. The University of Michigan now hosts the Isuzu engine and the project ATS for fuels testing. The Coordinating Research Council awarded follow-on funding to UM to extend the fuels matrix into biodiesel blends with renewable diesel, leveraging the DOE-funded hardware after the project closes.

  • Case Studies Evaluating a New IMU Solution for Geohazards

    by Rhett Dotson, Karim Kabbara, Dan Fletcher, Jeff Haferd

    The world's premier source for conference proceedings, offering Print-on-Demand, DOI, and Content Hosting services.

  • On-Site Diagnostic Reference Electrode Coupon Assembly Installation Utilizing Extendable Probe Rod Tool

    by Ryan Ell, Abed Sneineh

    The purpose of this study is to demonstrate the feasibility of utilizing an extendable probe rod tool to install an on-site diagnostic reference electrode coupon assembly at an existing cathodic protection test station. Conventional methods for installing a stationary reference electrode coupon assembly include mechanical excavation (via backhoe bucket or auger attachment) and vacuum excavation (via wet-vac or air-hammer methods). These traditional methods require a multi-person crew, heavy equipment, permitting, coordination, and safety procedures to avoid potentially hazardous working conditions and minimize unnecessary land disturbance. In addition, the labor involved with these types of installations is often expensive, especially when heavy equipment and multiple person crews are required to mobilize to remote locations. Such logistical demands often delay critical data acquisition, especially in situations requiring rapid assessment of cathodic protection effectiveness. A new installation method, utilizing an extendable probe rod tool, is proposed to mitigate the limitations of the conventional installation approaches. The method involves driving a small-diameter pilot hole, using the extendable probe rod tool, which allows for the insertion of a compact diagnostic reference electrode coupon assembly to the depth of the pipeline. This innovative technique can be executed by a single technician on-site, with minimal preparation, reduced risk, and virtually no surface disruption. The simplicity and efficiency of the process not only reduce operational cost and time but also enable immediate data acquisition for diagnostic and troubleshooting purposes. This can prove essential for identifying and resolving cathodic protection deficiencies in a timely and effective manner, particularly in remote, congested, or environmentally sensitive environments where traditional installation methods are often impractical. The probe rod installation method is protected under United States Patents 11,447,877; 11,807,945; and 12,043,906; and offers a significant advancement in pipeline integrity monitoring and maintenance practices.

  • The Path to Decarbonization Through Electrification: A Refinery Case Study and Lessons Learned

    by Giovanni Parra, Alia Hardy, Luis Espinoza, Sina Ghods

    The oil and gas industry faces the challenge of strategically becoming more efficient, sustainable, and environmentally responsive. For the industry to achieve that transformation, decarbonization is one option, and a key solution therein is decarbonation through electrification, a process that involves modifying, upgrading, and/or replacing steam-driven assets with more efficient electrically driven equipment. The electrification process also requires new sources of energy, a robust power system, and possibly even the reconfiguration or upgrade of electrical distribution. Alternatively, improvement of energy efficiency is another option to rise to these new industry challenges. In this article, the authors present a refinery case study using an actual project with close to 40,000 hp of electrification and improved efficiency, including the path taken from a technical perspective and the various challenges and lessons learned for a successful execution.

  • Arc Flash Anaysis for Electrication Projects How Far Upstream and Downstream Should Be Re-Evaluated a Refinery Case Study

    by Tony Acayan, Albert Marroquin, Jimmy Singh, Varsha Rajpurohit, Sina Ghods

    This paper will review the implementation and share lessons learned of an arc flash analysis study that was performed in support of a large infrastructure refinery project in Southern California. This paper is a follow-up to PCIC2024-5 paper titled "THE PATH TO DECARBONIZATION TROUGH ELECTRIFICATION, A REFINERY CASE STUDY AND LESSONS LEARNED" [1] presented in the General session in Orlando, FL.Because of the extensive modifications to the existing refinery facilities, short-circuit and arc-flash (AF) incident energy (IE) values were re-evaluated. This paper will review how far upstream and downstream the re-evaluation took place. The goal of this paper is to serve as a reference and refresher guide for protection engineers performing arc-flash analysis.The goal of arc-flash analysis is to ensure full compliance with the project criterion established with the latest standards and regulations. The arc flash levels identified in the study and NFPA 70E allow the facilities to classify the IE at various locations to help identify the proper personal protective equipment (PPE) rating to ensure personnel safety.

  • Determining Flushing Efficacy on Pipelines Using Ultrasonic Sensors

    by Hans Meyer, Logen Wolford, Dylan Spano

    Flushing was being utilized as an internal corrosion mitigation in relief lines of crude pipeline facilities; however, the efficacy of flushing for removing settled bottoms, sediment, and water in the relief piping was unknown. A project was developed to utilize permanently installed ultrasonic sensors to characterize what occurs during a flush event and whether that event was effective at removing deposits and reducing corrosion rates. Ultrasonics are normally utilized for measuring wall thickness in steel pipe, but sound waves travel beyond the back wall of the steel. Differences in the ultrasonic wave forms are observable in pipes filled with varying amounts of water, oil, and sediment. Waveforms of different conditions of water, oil, and sludge were gathered in the lab and used to train an artificial intelligence (AI) model which was utilized to interpret waveforms of the permanently installed sensors in the field before, during, and after flush events.