Von Roll (Switzerland)

Type
CompanyLocations
Breitenbach, SwitzerlandLatest Publications
- 5 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Comparison of the Dissipation Factor of Insulating Resins With and Without Anhydride Curing Agents
The most main wall insulations of rotating electrical high voltage machines consists of several layers of wound mica tape impregnated with epoxy resins. Methylhexahydrophthalic anhydride and Hexahydrophthalic anhydride are the state-of-the-art curing agents in epoxy insulations and are therefore essential components of the insulation system. Both anhydrides were proposed to the candidate list of Substances of Very High Concern and are therefore part of the European REACH authorization process. The prohibition or restricted use of both anhydrides in Europe in the future is possible and puts high pressure on the European manufacturers of electrical devices. Possible substitutes are available, but have to be qualified e.g. with respect to their dielectric properties. Hence, this paper compares several insulating resin systems with and without anhydride curing agents regarding their dielectric loss behavior. The results reveal that the curing agent has a measurable effect on the dielectric losses. Furthermore, the investigated anhydride-free insulation systems are a viable substitute at least with regard to their dielectric losses.
- 5 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Comparison of the Dissipation Factor of Insulating Resins With and Without Anhydride Curing Agents
The most main wall insulations of rotating electrical high voltage machines consists of several layers of wound mica tape impregnated with epoxy resins. Methylhexahydrophthalic anhydride and Hexahydrophthalic anhydride are the state-of-the-art curing agents in epoxy insulations and are therefore essential components of the insulation system. Both anhydrides were proposed to the candidate list of Substances of Very High Concern and are therefore part of the European REACH authorization process. The prohibition or restricted use of both anhydrides in Europe in the future is possible and puts high pressure on the European manufacturers of electrical devices. Possible substitutes are available, but have to be qualified e.g. with respect to their dielectric properties. Hence, this paper compares several insulating resin systems with and without anhydride curing agents regarding their dielectric loss behavior. The results reveal that the curing agent has a measurable effect on the dielectric losses. Furthermore, the investigated anhydride-free insulation systems are a viable substitute at least with regard to their dielectric losses.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 11 (00849162) , 919-923
Nano-structured hybrid sheets for electrotechnical high-power insulating applications: The sol-gel route
Among the new insulating materials to be used in high-voltage insulation, hybrid organic/inorganic nanocomposites have received a great attention. Indeed, these materials are gaining in popularity as an effective dielectric insulator with high temperature resistance. This research route is a part of the ANASTASIA consortium, which is made up of a balanced team of academic and industrial partners, and set out to address the wider topic of the reliable production of high performance nanodielectrics. Inorganic micro/nanofillers can be exploited for improving the breakdown strength, the dielectric permittivity and thermal conductivity of polymeric materials, using a sol-gel approach. Literature surveys identified some fillers as potential candidates for insulation applications. These sol-gel techniques show that all the hybrid systems present a structure based on amorphous metal-oxo nanodomains embedded within the polymer network. We further observed a strong influence of the cross-linking metal nature on the size of the metal-oxo nanoparticles and on the extent of the interface between inorganic domains and the polymer phase. Spectroscopic measurements revealed an important nanophase separation for the polymer systems incorporating for example Si(IV), Al(III), Ti(IV), or Zr(IV) alkoxides as cross-linking agents. Preliminary characterization has shown enhanced thermal conductivity and electrical performance for these nanostructured materials, compared with performance of current thermosets. Another advantage brought by this sol-gel technology is the wide choice of fillers and matrix compositions in order to design the mechanical, thermal and dielectric properties of the resulting nanocomposite. This paper will discuss the processes by which inorganic fillers are introduced and how the dielectric and thermal properties are thus improved.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 11 (00849162) , 919-923
Nano-structured hybrid sheets for electrotechnical high-power insulating applications: The sol-gel route
Among the new insulating materials to be used in high-voltage insulation, hybrid organic/inorganic nanocomposites have received a great attention. Indeed, these materials are gaining in popularity as an effective dielectric insulator with high temperature resistance. This research route is a part of the ANASTASIA consortium, which is made up of a balanced team of academic and industrial partners, and set out to address the wider topic of the reliable production of high performance nanodielectrics. Inorganic micro/nanofillers can be exploited for improving the breakdown strength, the dielectric permittivity and thermal conductivity of polymeric materials, using a sol-gel approach. Literature surveys identified some fillers as potential candidates for insulation applications. These sol-gel techniques show that all the hybrid systems present a structure based on amorphous metal-oxo nanodomains embedded within the polymer network. We further observed a strong influence of the cross-linking metal nature on the size of the metal-oxo nanoparticles and on the extent of the interface between inorganic domains and the polymer phase. Spectroscopic measurements revealed an important nanophase separation for the polymer systems incorporating for example Si(IV), Al(III), Ti(IV), or Zr(IV) alkoxides as cross-linking agents. Preliminary characterization has shown enhanced thermal conductivity and electrical performance for these nanostructured materials, compared with performance of current thermosets. Another advantage brought by this sol-gel technology is the wide choice of fillers and matrix compositions in order to design the mechanical, thermal and dielectric properties of the resulting nanocomposite. This paper will discuss the processes by which inorganic fillers are introduced and how the dielectric and thermal properties are thus improved.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23340975,p. 27-31
Developments relating to litz wire in the insulation systems of generators for renewable energies
As new designs for generators applied in the renewable energy market appear and rated power continues to increase, litz-wire winding technology has brought its advantages to machine and process efficiency. The division into many strands increases flexibility, facilitating the processing of larger and special windings, and reduces high-frequency winding resistance, reducing losses. The use of litz wire, however, impacts the insulation system. The litz-wire profile locally enhances electric field strength, with implications for the mainwall and turn insulations. Conductor mica tape can provide appropriate turn insulation, but influences wire flexibility, coil consolidation, and finally resin penetration during impregnation. During vacuum-pressure impregnation, resin should penetrate both the region between turns and the litz wire itself, without draining during curing. This can impose new requirements on the impregnation process and on the choice of resin, which must deal with low pressure and lack of catalyst inside the litz wire. The paper reports on considerations and investigations of such aspects in real generator designs.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23340975,p. 27-31
Developments relating to litz wire in the insulation systems of generators for renewable energies
As new designs for generators applied in the renewable energy market appear and rated power continues to increase, litz-wire winding technology has brought its advantages to machine and process efficiency. The division into many strands increases flexibility, facilitating the processing of larger and special windings, and reduces high-frequency winding resistance, reducing losses. The use of litz wire, however, impacts the insulation system. The litz-wire profile locally enhances electric field strength, with implications for the mainwall and turn insulations. Conductor mica tape can provide appropriate turn insulation, but influences wire flexibility, coil consolidation, and finally resin penetration during impregnation. During vacuum-pressure impregnation, resin should penetrate both the region between turns and the litz wire itself, without draining during curing. This can impose new requirements on the impregnation process and on the choice of resin, which must deal with low pressure and lack of catalyst inside the litz wire. The paper reports on considerations and investigations of such aspects in real generator designs.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 16 (1089084X) , 1-5
Insulating systems for high voltage rotating machines and reliability considerations
High-voltage rotating machines cover nominal voltages of 3.3-30 kV, with power outputs ranging from 0.1 MW to over 1000 MW. They are used as drives in the industry where high power is required and as generators in power plants. In all cases they must operate efficiently in harsh environments, therefore reliability and low-maintenance operation are key. In particular, power generators are viewed as long-term investments with an expected lifetime of up to 40 years. The design and manufacture of rotating machines must deal with these requirements, and the insulating system of a high-voltage rotating machine has a substantial influence on its lifetime. It is therefore important that it be carefully selected and applied.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 16 (1089084X) , 1-5
Insulating systems for high voltage rotating machines and reliability considerations
High-voltage rotating machines cover nominal voltages of 3.3-30 kV, with power outputs ranging from 0.1 MW to over 1000 MW. They are used as drives in the industry where high power is required and as generators in power plants. In all cases they must operate efficiently in harsh environments, therefore reliability and low-maintenance operation are key. In particular, power generators are viewed as long-term investments with an expected lifetime of up to 40 years. The design and manufacture of rotating machines must deal with these requirements, and the insulating system of a high-voltage rotating machine has a substantial influence on its lifetime. It is therefore important that it be carefully selected and applied.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Micaceous mainwall insulation for high-voltage rotating machines
The mineral mica has found application in the mainwall insulation of high-voltage electric rotating machines for over a century, and remains intrinsic to achieving high machine reliability and lifetimes. This paper retraces the historical development of micaceous mainwall insulation, and examines the materials and construction of modern mica tapes in detail. In this context, we provide examples of the multitude of available mica tapes, and review various properties of mica tapes relevant to their manufacture, application, and performance, concluding with some observed trends.
- 1 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Micaceous mainwall insulation for high-voltage rotating machines
The mineral mica has found application in the mainwall insulation of high-voltage electric rotating machines for over a century, and remains intrinsic to achieving high machine reliability and lifetimes. This paper retraces the historical development of micaceous mainwall insulation, and examines the materials and construction of modern mica tapes in detail. In this context, we provide examples of the multitude of available mica tapes, and review various properties of mica tapes relevant to their manufacture, application, and performance, concluding with some observed trends.
- 1 May 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 338-342
Suppression of partial discharges in high-voltage rotating machines
Partial discharge in high-voltage electric rotating machines is unfavorable to the long-term operation of the machines and is associated with insulation failure. Throughout this history of manufacturing these machines, materials and techniques have been developed to suppress the onset of partial discharge, so that a number of modern solutions are available to manufacturers and repair shops. This paper is specifically intended as an introduction to classic design issues and solutions, providing information on the properties of materials used in the suppression of PD and on their selection for and application to high-voltage rotating machines. It also reviews a selection of recent material developments.
- 1 May 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 338-342
Suppression of partial discharges in high-voltage rotating machines
Partial discharge in high-voltage electric rotating machines is unfavorable to the long-term operation of the machines and is associated with insulation failure. Throughout this history of manufacturing these machines, materials and techniques have been developed to suppress the onset of partial discharge, so that a number of modern solutions are available to manufacturers and repair shops. This paper is specifically intended as an introduction to classic design issues and solutions, providing information on the properties of materials used in the suppression of PD and on their selection for and application to high-voltage rotating machines. It also reviews a selection of recent material developments.
- 29 July 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 24 (4) , 17-25
Insulation Failure Mechanisms of Power Generators [Feature Article]
This article discusses about the abnormal or faulty operating condition of premature power generator insulation failures that can be classified as: design failures, material failures, manufacturing failures and maintenance failures. The final failure of the mica insulation is usually caused by electric breakdown through a tree channel. Formation and propagation of trees in the insulation therefore reflect the aging process of the insulation.
- 29 July 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electrical Insulation Magazine
- Vol. 24 (4) , 17-25
Insulation Failure Mechanisms of Power Generators [Feature Article]
This article discusses about the abnormal or faulty operating condition of premature power generator insulation failures that can be classified as: design failures, material failures, manufacturing failures and maintenance failures. The final failure of the mica insulation is usually caused by electric breakdown through a tree channel. Formation and propagation of trees in the insulation therefore reflect the aging process of the insulation.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Conference Record of the 2008 IEEE International Symposium on Electrical Insulation
- No. 1089084X,p. 257-260
Insulation Systems for Rotating Low-Voltage Machines
The insulation systems of low-voltage rotating machines tend to be relatively simple, but nevertheless comprise several materials that must be selected to work together. The insulating components can be classified into three groups according to their function, including magnet-wire insulation and the ground/slot and phase insulations, the so-called major insulation. The impregnating liquid (varnish or resin) is also an essential component of most low-voltage insulation systems. Its glues the coils, providing mechanical strength and reducing coil vibration. Polyester, polyesterimide, and epoxy are the principle chemistries for this application. Adhesive tapes, lead sleevings, cords and rigid materials, as for instance the rotor end ring, complete the listing of low-voltage insulating materials, and are used as process aids and considered minor insulation. This paper reviews the types and uses of the insulation components within a low-voltage insulation system.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Conference Record of the 2008 IEEE International Symposium on Electrical Insulation
- No. 1089084X,p. 257-260
Insulation Systems for Rotating Low-Voltage Machines
The insulation systems of low-voltage rotating machines tend to be relatively simple, but nevertheless comprise several materials that must be selected to work together. The insulating components can be classified into three groups according to their function, including magnet-wire insulation and the ground/slot and phase insulations, the so-called major insulation. The impregnating liquid (varnish or resin) is also an essential component of most low-voltage insulation systems. Its glues the coils, providing mechanical strength and reducing coil vibration. Polyester, polyesterimide, and epoxy are the principle chemistries for this application. Adhesive tapes, lead sleevings, cords and rigid materials, as for instance the rotor end ring, complete the listing of low-voltage insulating materials, and are used as process aids and considered minor insulation. This paper reviews the types and uses of the insulation components within a low-voltage insulation system.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1089084X,p. 162-165
High Voltage Insulation Failure Mechanisms
There are many statistics dealing with failure causes of high voltage rotating machines. While these statistics prove the relevance of the insulation as failure cause, they give little information on the real failure mechanism. This paper gives results of a research project which was launched to investigate degradation and final breakdown of the mica insulation in rotating machines. Final failure of the insulation is usually caused by electric breakdown through a tree channel. Formation and propagation of trees in the mica insulation therefore reflect the ageing process of the insulation. Dominating ageing factors of the mica insulation are thermal and mechanical stress. Manufacturing defects of the mica insulation - such as delaminations, cracks, voids and wrinkled or damaged mica layers - accelerate the formation and propagation of trees. Good workmanship and proper selection and application of the insulation materials are important factors for the lifetime of high voltage rotating machines.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1089084X,p. 162-165
High Voltage Insulation Failure Mechanisms
There are many statistics dealing with failure causes of high voltage rotating machines. While these statistics prove the relevance of the insulation as failure cause, they give little information on the real failure mechanism. This paper gives results of a research project which was launched to investigate degradation and final breakdown of the mica insulation in rotating machines. Final failure of the insulation is usually caused by electric breakdown through a tree channel. Formation and propagation of trees in the mica insulation therefore reflect the ageing process of the insulation. Dominating ageing factors of the mica insulation are thermal and mechanical stress. Manufacturing defects of the mica insulation - such as delaminations, cracks, voids and wrinkled or damaged mica layers - accelerate the formation and propagation of trees. Good workmanship and proper selection and application of the insulation materials are important factors for the lifetime of high voltage rotating machines.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Conference Record of the 2008 IEEE International Symposium on Electrical Insulation
- No. 1089084X,p. 571-574
Considerations for Rotating Low-Voltage Machine Insulation Designs
A low-voltage insulation system comprises a multitude of materials, carefully chosen to provide the desired service life of the device. As such, the interaction of the materials with the design and in the manufacturing process, as well as aging in use, needs also to be considered. This paper gives an overview of types of low-voltage of motors and generators, including critical factors regarding application and operation as well as technical insulation solutions.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Conference Record of the 2008 IEEE International Symposium on Electrical Insulation
- No. 1089084X,p. 571-574
Considerations for Rotating Low-Voltage Machine Insulation Designs
A low-voltage insulation system comprises a multitude of materials, carefully chosen to provide the desired service life of the device. As such, the interaction of the materials with the design and in the manufacturing process, as well as aging in use, needs also to be considered. This paper gives an overview of types of low-voltage of motors and generators, including critical factors regarding application and operation as well as technical insulation solutions.