25 DMEK grafts prepared from corneas stored in TISSUE-C and CARRY-C (deswelling medium) show similar viable endothelial cell density
Purpose The potential cytotoxicity of dextran-containing deswelling media used during Descemet membrane endothelial keratoplasty (DMEK) graft preparation remains controversial. This study compared endo-thelial viability and viable endothelial cell density (vECD) between deswelled and non-deswelled human corneas.Methods Eight pairs of human donor corneas preserved in standard organ culture medium (TISSUE-C) were in-cluded. Baseline endothelial cell density (ECD) was assessed at two time points (ECD1, ECD2) and was comparable between paired corneas. Two days before DMEK preparation, one cornea from each pair was transferred to a 6% dextran-containing deswelling medium (CARRY-C), while the contralateral cornea remained in TISSUE-C as control. On the day of graft preparation, ECD (ECD3) was measured. Endothelial viability and vECD were assessed using Hoechst-33342/Calcein-AM staining, and endothelial morpholo-gy was evaluated by CD166 immunofluorescence.Results ECD was higher in control than in deswelled corneas (2150 ± 737 vs. 1708 ± 745 cells/mm 2, p = 0.0176), confirmed by Hoechst-based analysis (p = 0.0167). Endothelial viability was significantly higher after deswelling (96% vs. 78%, p = 0.0013), resulting in comparable vECD between groups (1712 ± 723 vs. 1628 ± 715 cells/mm2, p = 0.3733). In control corneas, non-viable areas were associated with endothelial folds caused by corneal edema. Deswelling markedly reduced folds, and endothelial cell migration from viable to previously non-viable areas was observed, explaining the lower measured ECD after deswelling.Conclusions Short-term dextran-based deswelling reduces the measured ECD but does not decrease the total num-ber of viable endothelial cells. The apparent ECD reduction reflects endothelial cell redistribution rather than cytotoxicity. These findings support the safety of dextran-containing deswelling media for DMEK graft preparation and are likely applicable to penetrating keratoplasty.
- 25 August 2026
- Published by BMJ
- Vol. 11 (Suppl 2) , A12.2-A12
Open Access25 DMEK grafts prepared from corneas stored in TISSUE-C and CARRY-C (deswelling medium) show similar viable endothelial cell density
Purpose The potential cytotoxicity of dextran-containing deswelling media used during Descemet membrane endothelial keratoplasty (DMEK) graft preparation remains controversial. This study compared endo-thelial viability and viable endothelial cell density (vECD) between deswelled and non-deswelled human corneas.Methods Eight pairs of human donor corneas preserved in standard organ culture medium (TISSUE-C) were in-cluded. Baseline endothelial cell density (ECD) was assessed at two time points (ECD1, ECD2) and was comparable between paired corneas. Two days before DMEK preparation, one cornea from each pair was transferred to a 6% dextran-containing deswelling medium (CARRY-C), while the contralateral cornea remained in TISSUE-C as control. On the day of graft preparation, ECD (ECD3) was measured. Endothelial viability and vECD were assessed using Hoechst-33342/Calcein-AM staining, and endothelial morpholo-gy was evaluated by CD166 immunofluorescence.Results ECD was higher in control than in deswelled corneas (2150 ± 737 vs. 1708 ± 745 cells/mm 2, p = 0.0176), confirmed by Hoechst-based analysis (p = 0.0167). Endothelial viability was significantly higher after deswelling (96% vs. 78%, p = 0.0013), resulting in comparable vECD between groups (1712 ± 723 vs. 1628 ± 715 cells/mm2, p = 0.3733). In control corneas, non-viable areas were associated with endothelial folds caused by corneal edema. Deswelling markedly reduced folds, and endothelial cell migration from viable to previously non-viable areas was observed, explaining the lower measured ECD after deswelling.Conclusions Short-term dextran-based deswelling reduces the measured ECD but does not decrease the total num-ber of viable endothelial cells. The apparent ECD reduction reflects endothelial cell redistribution rather than cytotoxicity. These findings support the safety of dextran-containing deswelling media for DMEK graft preparation and are likely applicable to penetrating keratoplasty.
- Open Access
- 1 July 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 15 (7) , 1
Preclinical Safety and Feasibility Study of Line-Field Confocal Optical Coherence Tomography for Ophthalmology Applications
The purpose of this study was to demonstrate the first use of a commercially available, CE-marked line-field confocal optical coherence tomography (LC-OCT) in ophthalmology and assess its safety and feasibility for ocular imaging in rabbits, focusing on phototoxicity and tissue integrity. Five 14-week-old New Zealand White rabbits underwent corneal imaging using the DeepLive device (DAMAE Medical, Paris, France), originally developed for dermatologic applications. Imaging sessions lasted 5 to 10 minutes per eye, using illumination at a center wavelength of 820 nm and a power of 13.2 mW. Safety was evaluated in silico according to International Electrotechnical Commission (IEC) 60825-1 standards and in vivo through clinical assessments including slit-lamp examination, retinal imaging, and intraocular pressure (IOP) measurements at baseline, immediately after imaging, and on days 7 and 14. Histological analysis was performed day 14. LC-OCT provided high-resolution three-dimensional imaging of the cornea (1.2 × 0.5 × 0.5 mm) and two-dimensional views of corneal layers, conjunctiva, and the nictitating membrane, revealing cellular details. In silico analysis confirmed that laser exposure remained below IEC safety limits. In vivo evaluations showed no corneal opacity, neovascularization, inflammation, or retinal alterations at any time point. Lens transparency remained normal (Lens Opacities Classification System [LOCS] III grade = 0), and IOP showed no treatment-related differences (P = 0.6713). Histology confirmed preservation of corneal and retinal structures. Ophthalmologic use of CE-marked LC-OCT demonstrated safe, effective imaging in rabbits without phototoxicity, supporting its potential for clinical ophthalmic applications. These findings provide preclinical safety evidence supporting LC-OCT as a noninvasive, high-resolution imaging modality for future clinical ophthalmology applications.
- 1 July 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 15 (7) , 1
Open AccessPreclinical Safety and Feasibility Study of Line-Field Confocal Optical Coherence Tomography for Ophthalmology Applications
The purpose of this study was to demonstrate the first use of a commercially available, CE-marked line-field confocal optical coherence tomography (LC-OCT) in ophthalmology and assess its safety and feasibility for ocular imaging in rabbits, focusing on phototoxicity and tissue integrity. Five 14-week-old New Zealand White rabbits underwent corneal imaging using the DeepLive device (DAMAE Medical, Paris, France), originally developed for dermatologic applications. Imaging sessions lasted 5 to 10 minutes per eye, using illumination at a center wavelength of 820 nm and a power of 13.2 mW. Safety was evaluated in silico according to International Electrotechnical Commission (IEC) 60825-1 standards and in vivo through clinical assessments including slit-lamp examination, retinal imaging, and intraocular pressure (IOP) measurements at baseline, immediately after imaging, and on days 7 and 14. Histological analysis was performed day 14. LC-OCT provided high-resolution three-dimensional imaging of the cornea (1.2 × 0.5 × 0.5 mm) and two-dimensional views of corneal layers, conjunctiva, and the nictitating membrane, revealing cellular details. In silico analysis confirmed that laser exposure remained below IEC safety limits. In vivo evaluations showed no corneal opacity, neovascularization, inflammation, or retinal alterations at any time point. Lens transparency remained normal (Lens Opacities Classification System [LOCS] III grade = 0), and IOP showed no treatment-related differences (P = 0.6713). Histology confirmed preservation of corneal and retinal structures. Ophthalmologic use of CE-marked LC-OCT demonstrated safe, effective imaging in rabbits without phototoxicity, supporting its potential for clinical ophthalmic applications. These findings provide preclinical safety evidence supporting LC-OCT as a noninvasive, high-resolution imaging modality for future clinical ophthalmology applications.
- Open Access
- 2 March 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 15 (3) , 19
Storage of Corneas With Predissected Descemet Membrane in an Active Storage Machine
We previously demonstrated the superiority of an active storage machine (ASM; which restores a physiologic intraocular pressure [IOP]) over conventional passive storage for whole corneas. To reduce surgical time, corneas are often predissected in eye banks, 2 to 4 days before surgery for endothelial keratoplasty. The aim is here to demonstrate the possibility of also storing predissected Descemet membrane endothelial keratoplasty (DMEK) in ASM so that their use is not limited to penetrating keratoplasty and to extend the storage life of these endothelial grafts for much more flexibility. In this preclinical study, pairs of human corneas were predissected, leaving the Descemet membrane attached only by a small central area. After randomization, they were stored in the same commercial organ culture medium, either in the ASM (21 millimeters of mercury [mm Hg], 2.6 µL/min) or in a sealed flask, for 3 or 10 days. Final assessment consisted of measuring the viable endothelial cell density (ECD), corneal thickness, and assessing the expression of CD166 and NCAM, ZO-1 (morphology and junctions), Na+/K+ATPase (endothelial pump) and COX-IV (mitochondria) by immunostaining. Final endothelial cell (EC) viability was comparable between the two groups for both storage periods, as were the markers studied by immunofluorescence. However, corneal thickness was lower in the ASM group. In conclusion, the ASM can be used for predissected DMEK for at least 10 days, thus enabling to organize runs of graft preparation and subsequent safe storage while simplifying logistics. ASM can be used to preserve pre-cut DMEK grafts, providing greater flexibility in surgical planning. Nous avons précédemment démontré la supériorité d'un dispositif de stockage actif (ASM, qui rétablit une pression intraoculaire physiologique) par rapport au stockage passif conventionnel pour les cornées entières. Afin de réduire la durée de la chirurgie, les cornées sont souvent prédécoupées dans les banques de tissus, 2 à 4 jours avant la chirurgie, pour une greffe endothéliale. L'objectif ici est de démontrer la possibilité de stocker également des DMEK prédécoupées dans l'ASM afin que son utilisation ne se limite pas à la kératoplastie transfixiante et de prolonger la durée de conservation de ces greffons endothéliaux pour une plus grande flexibilité. Dans cette étude préclinique, des paires de cornées humaines ont été prédisséquées, en laissant l'endothélium attaché seulement par une petite zone centrale. Après randomisation, elles ont été conservées dans le même milieu commercial d'organoculture, soit dans l'ASM (21 mmHg, 2,6 µL/min), soit dans un flacon scellé, pendant 3 ou 10 jours. L'évaluation finale a consisté à mesurer la densité cellulaire endothéliale viable, l'épaisseur de la cornée, et à évaluer l'expression de CD166 et NCAM, ZO-1 (morphologie et jonctions), Na+/K+ATPase (pompe endothéliale) et COX-IV (mitochondries) par immunomarquage. La viabilité cellulaire endothéliale finale était comparable entre les deux groupes pour les deux périodes de conservation, tout comme les marqueurs étudiés par immunofluorescence. Cependant, l'épaisseur cornéenne était plus faible dans le groupe ASM. En conclusion, l'ASM peut être utilisée pour les DMEK prédécoupées pendant au moins 10 jours, ce qui permet d'organiser des séries de préparation de greffons et leur stockage ultérieur en toute sécurité, tout en simplifiant la logistique. L'ASM peut être utilisé pour préserver des greffons de DMEK prédécoupés et ainsi apporter plus de flexibilité dans l'organisation d'une chirurgie.
- 2 March 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 15 (3) , 19
Open AccessStorage of Corneas With Predissected Descemet Membrane in an Active Storage Machine
We previously demonstrated the superiority of an active storage machine (ASM; which restores a physiologic intraocular pressure [IOP]) over conventional passive storage for whole corneas. To reduce surgical time, corneas are often predissected in eye banks, 2 to 4 days before surgery for endothelial keratoplasty. The aim is here to demonstrate the possibility of also storing predissected Descemet membrane endothelial keratoplasty (DMEK) in ASM so that their use is not limited to penetrating keratoplasty and to extend the storage life of these endothelial grafts for much more flexibility. In this preclinical study, pairs of human corneas were predissected, leaving the Descemet membrane attached only by a small central area. After randomization, they were stored in the same commercial organ culture medium, either in the ASM (21 millimeters of mercury [mm Hg], 2.6 µL/min) or in a sealed flask, for 3 or 10 days. Final assessment consisted of measuring the viable endothelial cell density (ECD), corneal thickness, and assessing the expression of CD166 and NCAM, ZO-1 (morphology and junctions), Na+/K+ATPase (endothelial pump) and COX-IV (mitochondria) by immunostaining. Final endothelial cell (EC) viability was comparable between the two groups for both storage periods, as were the markers studied by immunofluorescence. However, corneal thickness was lower in the ASM group. In conclusion, the ASM can be used for predissected DMEK for at least 10 days, thus enabling to organize runs of graft preparation and subsequent safe storage while simplifying logistics. ASM can be used to preserve pre-cut DMEK grafts, providing greater flexibility in surgical planning. Nous avons précédemment démontré la supériorité d'un dispositif de stockage actif (ASM, qui rétablit une pression intraoculaire physiologique) par rapport au stockage passif conventionnel pour les cornées entières. Afin de réduire la durée de la chirurgie, les cornées sont souvent prédécoupées dans les banques de tissus, 2 à 4 jours avant la chirurgie, pour une greffe endothéliale. L'objectif ici est de démontrer la possibilité de stocker également des DMEK prédécoupées dans l'ASM afin que son utilisation ne se limite pas à la kératoplastie transfixiante et de prolonger la durée de conservation de ces greffons endothéliaux pour une plus grande flexibilité. Dans cette étude préclinique, des paires de cornées humaines ont été prédisséquées, en laissant l'endothélium attaché seulement par une petite zone centrale. Après randomisation, elles ont été conservées dans le même milieu commercial d'organoculture, soit dans l'ASM (21 mmHg, 2,6 µL/min), soit dans un flacon scellé, pendant 3 ou 10 jours. L'évaluation finale a consisté à mesurer la densité cellulaire endothéliale viable, l'épaisseur de la cornée, et à évaluer l'expression de CD166 et NCAM, ZO-1 (morphologie et jonctions), Na+/K+ATPase (pompe endothéliale) et COX-IV (mitochondries) par immunomarquage. La viabilité cellulaire endothéliale finale était comparable entre les deux groupes pour les deux périodes de conservation, tout comme les marqueurs étudiés par immunofluorescence. Cependant, l'épaisseur cornéenne était plus faible dans le groupe ASM. En conclusion, l'ASM peut être utilisée pour les DMEK prédécoupées pendant au moins 10 jours, ce qui permet d'organiser des séries de préparation de greffons et leur stockage ultérieur en toute sécurité, tout en simplifiant la logistique. L'ASM peut être utilisé pour préserver des greffons de DMEK prédécoupés et ainsi apporter plus de flexibilité dans l'organisation d'une chirurgie.
- Open Access
- 25 February 2026
- Published by Wiley in The Journal of Pathology
- Vol. 269 (2) , 182-196
Pathological classification of Fuchs endothelial corneal dystrophy into several types and their relationships with CTG18 .1 expansion repeats
Late‐onset Fuchs endothelial corneal dystrophy (FECD) is the most common primary disease of the corneal endothelium and the leading indication for corneal transplantation in Western countries. It is characterized by progressive accumulation, over two to three decades, of extracellular matrix (ECM) components in Descemet's membrane (DM), leading to the formation of abnormal excrescences, known as guttae, and additional DM layers. Clinical forms and evolutionary profiles vary widely among patients. FECD is strongly associated with intronic CTG trinucleotide repeats (TNRs) in the transcription factor 4 ( TCF4 ) gene. We analysed 500 DMs removed during keratoplasty for FECD across 25 European centres to identify different anatomopathological forms of the disease. Following flat mounting and dehydration, the samples were digitized using transmitted light microscopy and independently assessed by three independent readers. A total of ten parameters – six related to guttae and four on other forms of ECM – were scored. Principal component analysis and an unsupervised clustering method separated three clusters from these parameters. In addition, manual classification was performed by grouping samples with major common features. The number of TNRs in TCF4 was analysed by short tandem repeat (STR)‐ and triplet repeat primed‐polymerase chain reaction (TP‐PCR) for 109 patients. We found that (1) five FECD phenotypes exist; (2) guttae and other ECM structures were radially arranged in 95% of samples; (3) 33% of samples exhibited peripheral radial striae that corresponded to a hypertrophied form of similar structures present in healthy corneas; and (4) patients with fewer than 50 TNRs had only two out of five phenotypes and had a significantly higher number of peripheral radial striae (94% versus 49%, p < 0.001). Taken together, these new findings demonstrate the existence of different FECD phenotypes; reveal that lesions affect both the centre and the periphery of the endothelium; and suggest that radial deposits may be produced by pathological cells migrating from the periphery towards the centre. © 2026 The Author(s). The Journal of Pathology published by John Wiley & Sons Ltd on behalf of The Pathological Society of Great Britain and Ireland.
- 25 February 2026
- Published by Wiley in The Journal of Pathology
- Vol. 269 (2) , 182-196
Open AccessPathological classification of Fuchs endothelial corneal dystrophy into several types and their relationships with CTG18 .1 expansion repeats
Late‐onset Fuchs endothelial corneal dystrophy (FECD) is the most common primary disease of the corneal endothelium and the leading indication for corneal transplantation in Western countries. It is characterized by progressive accumulation, over two to three decades, of extracellular matrix (ECM) components in Descemet's membrane (DM), leading to the formation of abnormal excrescences, known as guttae, and additional DM layers. Clinical forms and evolutionary profiles vary widely among patients. FECD is strongly associated with intronic CTG trinucleotide repeats (TNRs) in the transcription factor 4 ( TCF4 ) gene. We analysed 500 DMs removed during keratoplasty for FECD across 25 European centres to identify different anatomopathological forms of the disease. Following flat mounting and dehydration, the samples were digitized using transmitted light microscopy and independently assessed by three independent readers. A total of ten parameters – six related to guttae and four on other forms of ECM – were scored. Principal component analysis and an unsupervised clustering method separated three clusters from these parameters. In addition, manual classification was performed by grouping samples with major common features. The number of TNRs in TCF4 was analysed by short tandem repeat (STR)‐ and triplet repeat primed‐polymerase chain reaction (TP‐PCR) for 109 patients. We found that (1) five FECD phenotypes exist; (2) guttae and other ECM structures were radially arranged in 95% of samples; (3) 33% of samples exhibited peripheral radial striae that corresponded to a hypertrophied form of similar structures present in healthy corneas; and (4) patients with fewer than 50 TNRs had only two out of five phenotypes and had a significantly higher number of peripheral radial striae (94% versus 49%, p < 0.001). Taken together, these new findings demonstrate the existence of different FECD phenotypes; reveal that lesions affect both the centre and the periphery of the endothelium; and suggest that radial deposits may be produced by pathological cells migrating from the periphery towards the centre. © 2026 The Author(s). The Journal of Pathology published by John Wiley & Sons Ltd on behalf of The Pathological Society of Great Britain and Ireland.
- 23 September 2025
- Published by SAGE Publications in Tissue Engineering Part A
Tissue-Engineered Endothelial Keratoplasty with Controlled Cell Density: Toward Super TEEKs
Over the past 20 years, endothelial keratoplasty procedures have revolutionized the treatment of corneal endothelial disorders. These conditions have now become the leading indication for corneal transplantation in Western countries and account for half of all donor cornea usage. Despite their undeniable success, the global shortage of donor tissues and major disparities between nations justify the development of alternatives to donor grafts. Cell therapy using injections of suspended endothelial cells has proven effective, and tissue-engineered endothelial keratoplasty (TEEK), comprising a membrane coated with cultured endothelial cells, is under development to better mimic the native endothelial graft. Our team utilizes a femtosecond-laser-cut lens capsule disc as a bioengineering scaffold, taking advantage of this novel tissue's biocompatibility, transparency, curvature, and availability. In the present study, we provide proof of concept, in 12 TEEKs, that it is possible to control the final endothelial cell density (ECD) by varying the seeding density per mm2. Cell characterization was performed through morphometric analysis of the endothelial mosaic stained with anti-NCAM (a lateral membrane marker used as a differentiation marker), using the CellPose artificial intelligence algorithm specifically trained for in vitro endothelium segmentation. Five criteria related to pleomorphism, polymorphism, and elongation were combined into a single endothelial quality score. The median cell viability at 28 days of culture, assessed by Hoechst 33342 and Calcein-AM staining, reached 98% (range: 83-99%). The median viable ECD (number of live cells per surface unit) in the highest-density group was 3.245 cells/mm2 (range: 2.778-3.753), paving the way for the bioengineering of supra-physiological TEEKs, or "super TEEKs".
- 23 September 2025
- Published by SAGE Publications in Tissue Engineering Part A
Tissue-Engineered Endothelial Keratoplasty with Controlled Cell Density: Toward Super TEEKs
Over the past 20 years, endothelial keratoplasty procedures have revolutionized the treatment of corneal endothelial disorders. These conditions have now become the leading indication for corneal transplantation in Western countries and account for half of all donor cornea usage. Despite their undeniable success, the global shortage of donor tissues and major disparities between nations justify the development of alternatives to donor grafts. Cell therapy using injections of suspended endothelial cells has proven effective, and tissue-engineered endothelial keratoplasty (TEEK), comprising a membrane coated with cultured endothelial cells, is under development to better mimic the native endothelial graft. Our team utilizes a femtosecond-laser-cut lens capsule disc as a bioengineering scaffold, taking advantage of this novel tissue's biocompatibility, transparency, curvature, and availability. In the present study, we provide proof of concept, in 12 TEEKs, that it is possible to control the final endothelial cell density (ECD) by varying the seeding density per mm2. Cell characterization was performed through morphometric analysis of the endothelial mosaic stained with anti-NCAM (a lateral membrane marker used as a differentiation marker), using the CellPose artificial intelligence algorithm specifically trained for in vitro endothelium segmentation. Five criteria related to pleomorphism, polymorphism, and elongation were combined into a single endothelial quality score. The median cell viability at 28 days of culture, assessed by Hoechst 33342 and Calcein-AM staining, reached 98% (range: 83-99%). The median viable ECD (number of live cells per surface unit) in the highest-density group was 3.245 cells/mm2 (range: 2.778-3.753), paving the way for the bioengineering of supra-physiological TEEKs, or "super TEEKs".
- Open Access
- 29 August 2025
- Published by BMJ
- Vol. 10 (Suppl 3) , A20.3-A21
P.12. From lab configuration to functional prototype: active storage machine for corneal storage
Purpose The Active Storage Machine (ASM), was developed to improve corneal graft storage in eye banks. The proof-of-concept, the bioreactor (BR) published by our research team (Am. J. Transplant. 2019), demonstrated the feasibility of an active storage system that restores the intraocular pressure and medium renewal for improving ex vivo graft viability. The present study aims at presenting the successful translation of the proof of concept (from an academic laboratory) into a functional prototype which maintain comparable technical performance. The new results were also compared with conventional (i.e. passive) organ culture (OC).Methods Nine corneas were stored in the ASM for 27 days, using CorneaMax (Eurobio-Scientific) in a dry incubator at 31°C without CO2 supplementation, 30 mmHg and medium circulation. They were then kept at room temperature, without medium circulation, under 40 mmHg for 3 days to simulate shipping to the operating room. Endothelial cell density (ECD), corneal thickness, and pH (endothelial/epithelial) were measured on days 0 (except ECD), 1, 7, 14, 21, 27, and 30. ECD was measured using specular microscopy (CellCheck-D+, Konan), which allowed for continuous monitoring throughout the storage period. Alizarin red staining was performed at the end of the study to verify for endothelial integrity. Statistical comparisons were conducted between the ASM group from the current study and the BR and OC groups (50 corneas both) from the 2019 publication.Results The initial ECD was 2412±232 cells/mm² and the daily ECD loss in the ASM was 0.30% (95%CI 0.15–0.44%) over the 27 days of storage. Corneal thickness decreased from 852±209 μm to 616±34 μm. During the transport simulation, ECD loss was 1.29% (95%CI 0.63–1.96%), and thickness significantly decreased to 607±36 μm (p<0.05). pH levels increased in both epithelial and endothelial chambers. Alizarin red staining confirmed perfect endothelial integrity. Corneas into the ASM had lower cell loss than in OC (p0.05). After the 3 day-shipping simulation, corneal thickness was comparable to that of OC corneas deswelled in CorneaJet and the daily cell loss was 7 times lower.Conclusion The ASM effectively preserved corneas, demonstrating comparable technical performance to the initial BR and superior results compared to OC, confirming its potential for eye banking.
- 29 August 2025
- Published by BMJ
- Vol. 10 (Suppl 3) , A20.3-A21
Open AccessP.12. From lab configuration to functional prototype: active storage machine for corneal storage
Purpose The Active Storage Machine (ASM), was developed to improve corneal graft storage in eye banks. The proof-of-concept, the bioreactor (BR) published by our research team (Am. J. Transplant. 2019), demonstrated the feasibility of an active storage system that restores the intraocular pressure and medium renewal for improving ex vivo graft viability. The present study aims at presenting the successful translation of the proof of concept (from an academic laboratory) into a functional prototype which maintain comparable technical performance. The new results were also compared with conventional (i.e. passive) organ culture (OC).Methods Nine corneas were stored in the ASM for 27 days, using CorneaMax (Eurobio-Scientific) in a dry incubator at 31°C without CO2 supplementation, 30 mmHg and medium circulation. They were then kept at room temperature, without medium circulation, under 40 mmHg for 3 days to simulate shipping to the operating room. Endothelial cell density (ECD), corneal thickness, and pH (endothelial/epithelial) were measured on days 0 (except ECD), 1, 7, 14, 21, 27, and 30. ECD was measured using specular microscopy (CellCheck-D+, Konan), which allowed for continuous monitoring throughout the storage period. Alizarin red staining was performed at the end of the study to verify for endothelial integrity. Statistical comparisons were conducted between the ASM group from the current study and the BR and OC groups (50 corneas both) from the 2019 publication.Results The initial ECD was 2412±232 cells/mm² and the daily ECD loss in the ASM was 0.30% (95%CI 0.15–0.44%) over the 27 days of storage. Corneal thickness decreased from 852±209 μm to 616±34 μm. During the transport simulation, ECD loss was 1.29% (95%CI 0.63–1.96%), and thickness significantly decreased to 607±36 μm (p<0.05). pH levels increased in both epithelial and endothelial chambers. Alizarin red staining confirmed perfect endothelial integrity. Corneas into the ASM had lower cell loss than in OC (p0.05). After the 3 day-shipping simulation, corneal thickness was comparable to that of OC corneas deswelled in CorneaJet and the daily cell loss was 7 times lower.Conclusion The ASM effectively preserved corneas, demonstrating comparable technical performance to the initial BR and superior results compared to OC, confirming its potential for eye banking.
- Open Access
- 29 August 2025
- Published by BMJ
- Vol. 10 (Suppl 3) , A20.2-A20
P.11. Investigating the role of molecular coating in human corneal endothelial cell primary culture
The monolayer of approximately 300,000 human corneal endothelial cells (hCECs) on the posterior surface of the cornea is essential to maintain transparency but is non-self-regenerative. Corneal blindness can currently only be treated by corneal transplantation, hindered by a global donor shortage, highlighting the need for developing tissue and/or cell therapy. The mass production of these advanced therapy medicinal products requires obtaining high-yield, high-quality endothelial cell culture characterized by hexagonal shape, low size variability, and high endothelial cell density (ECD). Among the usual critical quality attributes that combine the expression of differentiation markers, ECD and cell morphology parameters, the latter are not optimally measured in vitro by conventional image analysis which poorly recognize adherent cultured cells. We developed a high-performance automated segmentation using Cellpose algorithm and an original analysis method, improving calculation of classical morphological parameters (coefficient of variation of cell area and hexagonality) and introducing new parameters specific to hCECs culture in vitro. Considering the importance of the extracellular matrix in vivo, and the panel of molecules available for coating cell culture plastics, we used these new tools to perform a comprehensive comparison of 13 molecules (laminins and collagens). We demonstrated their ability to discriminate subtle differences between cultures.
- 29 August 2025
- Published by BMJ
- Vol. 10 (Suppl 3) , A20.2-A20
Open AccessP.11. Investigating the role of molecular coating in human corneal endothelial cell primary culture
The monolayer of approximately 300,000 human corneal endothelial cells (hCECs) on the posterior surface of the cornea is essential to maintain transparency but is non-self-regenerative. Corneal blindness can currently only be treated by corneal transplantation, hindered by a global donor shortage, highlighting the need for developing tissue and/or cell therapy. The mass production of these advanced therapy medicinal products requires obtaining high-yield, high-quality endothelial cell culture characterized by hexagonal shape, low size variability, and high endothelial cell density (ECD). Among the usual critical quality attributes that combine the expression of differentiation markers, ECD and cell morphology parameters, the latter are not optimally measured in vitro by conventional image analysis which poorly recognize adherent cultured cells. We developed a high-performance automated segmentation using Cellpose algorithm and an original analysis method, improving calculation of classical morphological parameters (coefficient of variation of cell area and hexagonality) and introducing new parameters specific to hCECs culture in vitro. Considering the importance of the extracellular matrix in vivo, and the panel of molecules available for coating cell culture plastics, we used these new tools to perform a comprehensive comparison of 13 molecules (laminins and collagens). We demonstrated their ability to discriminate subtle differences between cultures.
- 28 July 2025
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 48 (8)
Principal obstacle technique à la DMEK chez le chien
- 28 July 2025
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 48 (8)
Principal obstacle technique à la DMEK chez le chien
- Open Access
- 2 June 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14 (6) , 11
Far-Red, High-Resolution, Reflection-Free Images of the Anterior Segment in Retro-Illumination
Examination of the anterior segment using retro-illumination is part of the routine clinical examination, but capturing images that can be used by the clinician remains a challenge because reflections are always present, resolution is insufficient, and the patient’s glare often causes motion blur. Our aim was therefore to overcome these limitations. We modified a slit lamp by using a far-red LED, a high-resolution camera, and by modifying the light path using polarizers and an obturator to suppress reflections while optimizing the light flux. We used this prototype to image various ocular conditions to illustrate its potential. With the ×40 magnification of the slit lamp, the prototype provided images with a resolution of 6.2 µm, and a field of view of 9.7 mm. We obtained images without motion blur in all patients. The vast majority of images were reflection-free. Only the images of a few patients with pseudophakia showed persistent small reflection. The resolution was sufficient to highlight, for example, all the Descemetic excrescences (Guttae) constitutive of a Fuchs endothelial corneal dystrophy (FECD). Our retro-illumination device prototype provides high-resolution images of the different structures of the anterior segment of the eye, easy to acquire mainly because they do not dazzle patients. We believe that these images have the potential to facilitate the diagnosis and monitoring of many different diseases both in routine use and in clinical trials where they could be used as objective endpoints. Our prototype revisits retro-illumination with a potential to become a new imaging device.
- 2 June 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14 (6) , 11
Open AccessFar-Red, High-Resolution, Reflection-Free Images of the Anterior Segment in Retro-Illumination
Examination of the anterior segment using retro-illumination is part of the routine clinical examination, but capturing images that can be used by the clinician remains a challenge because reflections are always present, resolution is insufficient, and the patient’s glare often causes motion blur. Our aim was therefore to overcome these limitations. We modified a slit lamp by using a far-red LED, a high-resolution camera, and by modifying the light path using polarizers and an obturator to suppress reflections while optimizing the light flux. We used this prototype to image various ocular conditions to illustrate its potential. With the ×40 magnification of the slit lamp, the prototype provided images with a resolution of 6.2 µm, and a field of view of 9.7 mm. We obtained images without motion blur in all patients. The vast majority of images were reflection-free. Only the images of a few patients with pseudophakia showed persistent small reflection. The resolution was sufficient to highlight, for example, all the Descemetic excrescences (Guttae) constitutive of a Fuchs endothelial corneal dystrophy (FECD). Our retro-illumination device prototype provides high-resolution images of the different structures of the anterior segment of the eye, easy to acquire mainly because they do not dazzle patients. We believe that these images have the potential to facilitate the diagnosis and monitoring of many different diseases both in routine use and in clinical trials where they could be used as objective endpoints. Our prototype revisits retro-illumination with a potential to become a new imaging device.
- Open Access
Tissue engineered endothelial keratoplasty with controlled endothelial cell density: proof of concept and paving the way for super TEEKs
Over the past 20 years, endothelial keratoplasty procedures have revolutionized the treatment of corneal endothelial disorders. These conditions have now become the leading indication for corneal transplantation in Western countries and account for half of all donor cornea usage. Despite their undeniable success, the global shortage of donor tissues and major disparities between nations justify the development of alternatives to donor grafts. Cell therapy using injections of suspended endothelial cells has proven effective, and tissue-engineered endothelial keratoplasty (TEEK) comprising a membrane coated with cultured endothelial cells is under development to better mimic the native endothelial graft. Our team utilizes a femtosecond-laser-cut lens capsule disc as a bioengineering scaffold, taking advantage of this novel tissue’s biocompatibility, transparency, curvature, and availability. In the present study, we provide proof of concept, in 12 TEEKs, that it is possible to control the final endothelial cell density (ECD) by varying the seeding density per mm 2 . Cell characterization was performed through morphometric analysis of the endothelial mosaic stained with anti-NCAM (a lateral membrane marker used as a differentiation marker), using the CellPose artificial intelligence algorithm specifically trained for in vitro endothelium segmentation. Five criteria related to pleomorphism, polymorphism, and elongation were combined into a single endothelial quality score. The median cell viability at 28 days of culture, assessed by Hoechst 33342 and Calcein-AM staining, reached 98% (range: 83–99%). The median viable ECD (number of live cells per surface unit) in the highest-density group was 3,245 cells/mm 2 (range: 2,778–3,753), paving the way for the bioengineering of supra-physiological TEEKs, or super TEEKs. Impact statement: The process of manufacturing tissue-engineered endothelial keratoplasty (TEEK) allows for the control of endothelial cell density (DCE) and, in particular, the creation of super TEEKs, meaning grafts with supra-physiological DCE that are more likely to better withstand the challenges of surgery and have a prolonged lifespan in recipients.
Open AccessTissue engineered endothelial keratoplasty with controlled endothelial cell density: proof of concept and paving the way for super TEEKs
Over the past 20 years, endothelial keratoplasty procedures have revolutionized the treatment of corneal endothelial disorders. These conditions have now become the leading indication for corneal transplantation in Western countries and account for half of all donor cornea usage. Despite their undeniable success, the global shortage of donor tissues and major disparities between nations justify the development of alternatives to donor grafts. Cell therapy using injections of suspended endothelial cells has proven effective, and tissue-engineered endothelial keratoplasty (TEEK) comprising a membrane coated with cultured endothelial cells is under development to better mimic the native endothelial graft. Our team utilizes a femtosecond-laser-cut lens capsule disc as a bioengineering scaffold, taking advantage of this novel tissue’s biocompatibility, transparency, curvature, and availability. In the present study, we provide proof of concept, in 12 TEEKs, that it is possible to control the final endothelial cell density (ECD) by varying the seeding density per mm 2 . Cell characterization was performed through morphometric analysis of the endothelial mosaic stained with anti-NCAM (a lateral membrane marker used as a differentiation marker), using the CellPose artificial intelligence algorithm specifically trained for in vitro endothelium segmentation. Five criteria related to pleomorphism, polymorphism, and elongation were combined into a single endothelial quality score. The median cell viability at 28 days of culture, assessed by Hoechst 33342 and Calcein-AM staining, reached 98% (range: 83–99%). The median viable ECD (number of live cells per surface unit) in the highest-density group was 3,245 cells/mm 2 (range: 2,778–3,753), paving the way for the bioengineering of supra-physiological TEEKs, or super TEEKs. Impact statement: The process of manufacturing tissue-engineered endothelial keratoplasty (TEEK) allows for the control of endothelial cell density (DCE) and, in particular, the creation of super TEEKs, meaning grafts with supra-physiological DCE that are more likely to better withstand the challenges of surgery and have a prolonged lifespan in recipients.