Preclinical Safety and Feasibility Study of Line-Field Confocal Optical Coherence Tomography for Ophthalmology Applications
Open Access
- 1 July 2026
- journal article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 15 (7) , 1
Abstract
The purpose of this study was to demonstrate the first use of a commercially available, CE-marked line-field confocal optical coherence tomography (LC-OCT) in ophthalmology and assess its safety and feasibility for ocular imaging in rabbits, focusing on phototoxicity and tissue integrity. Five 14-week-old New Zealand White rabbits underwent corneal imaging using the DeepLive device (DAMAE Medical, Paris, France), originally developed for dermatologic applications. Imaging sessions lasted 5 to 10 minutes per eye, using illumination at a center wavelength of 820 nm and a power of 13.2 mW. Safety was evaluated in silico according to International Electrotechnical Commission (IEC) 60825-1 standards and in vivo through clinical assessments including slit-lamp examination, retinal imaging, and intraocular pressure (IOP) measurements at baseline, immediately after imaging, and on days 7 and 14. Histological analysis was performed day 14. LC-OCT provided high-resolution three-dimensional imaging of the cornea (1.2 × 0.5 × 0.5 mm) and two-dimensional views of corneal layers, conjunctiva, and the nictitating membrane, revealing cellular details. In silico analysis confirmed that laser exposure remained below IEC safety limits. In vivo evaluations showed no corneal opacity, neovascularization, inflammation, or retinal alterations at any time point. Lens transparency remained normal (Lens Opacities Classification System [LOCS] III grade = 0), and IOP showed no treatment-related differences (P = 0.6713). Histology confirmed preservation of corneal and retinal structures. Ophthalmologic use of CE-marked LC-OCT demonstrated safe, effective imaging in rabbits without phototoxicity, supporting its potential for clinical ophthalmic applications. These findings provide preclinical safety evidence supporting LC-OCT as a noninvasive, high-resolution imaging modality for future clinical ophthalmology applications.Keywords
This publication has 43 references indexed in Scilit:
- High resolution corneal and single pulse imaging with line field spectral domain optical coherence tomographyOptics Express, 2016
- Does infrared or ultraviolet light damage the lens?Eye, 2016
- In vivocorneal confocal microscopy in diabetes: Where we are and where we can getWorld Journal of Diabetes, 2016
- Safety of cornea and iris in ocular surgery with 355-nm lasersJournal of Biomedical Optics, 2015
- Eyelid and ocular surface carcinoma: Diagnosis and managementClinics in Dermatology, 2015
- Anterior Segment Applications of In Vivo Confocal MicroscopySeminars in Ophthalmology, 2013
- Effect of sedation with xylazine and ketamine on intraocular pressure in New Zealand white rabbits.2013
- Contribution of In Vivo Confocal Microscopy to the Diagnosis and Management of Infectious KeratitisThe Ocular Surface, 2009
- Grading Of Corneal and Conjunctival Staining in the Context of Other Dry Eye TestsCornea, 2003
- The Lens Opacities Classification System IIIArchives of Ophthalmology (1950), 1993