Effect of beach chair position on bispectral index values during arthroscopic shoulder surgery
Authors:
Open Access
- 1 January 2014
- journal article
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 67 (4) , 235-239
Abstract
Bispectral index (BIS) monitoring reduces the cases of intraoperative awareness. Several factors can alter BIS readings without affecting the depth of anesthesia. We conducted a study to assess the impact of beach chair position (sitting position) on BIS readings. General anesthesia was administered to 30 patients undergoing arthroscopic shoulder surgery. Patients were kept in neutral position (supine) for 10 minutes and BIS readings, mean arterial blood pressure, heart rate, end-tidal carbon dioxide, and end-tidal sevoflurane were recorded. Patients were then shifted to beach chair position. After 15 minutes, data were recorded. A significant decrease in BIS values (P < 0.01) associated with a position change from neutral position to beach chair position was evident. BIS values are significantly decreased in the beach chair position compared with the neutral position and might affect interpretation of the depth of anesthesia.Keywords
This publication has 25 references indexed in Scilit:
- Chirurgie arthroscopique de l’épaule et complications ischémiques cérébralesAnnales Françaises d'Anesthésie et de Réanimation, 2012
- Cerebral oxygenation monitoring of patients during arthroscopic shoulder surgery in the sitting positionKorean Journal of Anesthesiology, 2012
- Does Patient Position Influence the Reading of the Bispectral Index Monitor?Anesthesia & Analgesia, 2009
- What happens to the brain in weightlessness? A first approach by EEG tomographyNeuroImage, 2008
- Bispectral index for improving anaesthetic delivery and postoperative recovery2007
- Different Conditions That Could Result in the Bispectral Index Indicating an Incorrect Hypnotic StateAnesthesia & Analgesia, 2005
- The effects of nitrous oxide and ketamine on the bispectral index and 95% spectral edge frequency during propofol–fentanyl anaesthesiaEuropean Journal of Anaesthesiology, 1999
- Relation between bispectral index and plasma catecholamines after oral diazepam premedicationEuropean Journal of Anaesthesiology, 1999
- Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced SedationAnesthesia & Analgesia, 1997
- Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced SedationAnesthesia & Analgesia, 1997