Operating Hardware Impact on the Heat Transfer Properties of Windows
Open Access
Abstract
Despite significant advancements in fenestration technology in the last two decades, the thermal transmittance of fenestration products is still significantly higher than that of walls. This corresponds to 60% of the total energy loss of a modern building envelope through the windows. Hence, further development and improvements of fenestration products are necessary. Increasingly stringent codes and standards for fenestration stimulate industry to work on improved solutions. Thus, it is crucial that assessment techniques are able to account for innovations accurately. The thermal effects of non-continuous hardware in window frames are currently ignored by international rating procedures. A preliminary investigation conducted by our team showed significant performance degradation in two of the three out-opening casement profiles caused by the presence of operating hardware. Frames with the structure made of vinyl and fiberglass consist of many air cavities that are penetrated by operating hardware made of highly conductive materials. In these frames, in order to have an accurate assessment, it may be required to employ three-dimensional modeling due to the convective nature of heat transfer within the cavities. However, in this study, we demonstrate that the three-dimensional (3D) effects of non-continuous hardware can be approximated accurately with simpler two-dimensional (2D) simulations. We then develop a simplified model based on weighted average capable of replacing the time- and computation-intensive 3D simulations with 2D simulations and validate it against market available frames and their corresponding hardware. Validation results show that our approximation technique results in discrepancies lower than 0.05 W/(m2K), or 3% of the total thermal transmittance. Thus, we conclude that simplified 2D simulation models may be used for predicting hardware impact in window frames with reasonable accuracy. As windows and glazing structures are becoming ever better thermally insulated, it is becoming even more important to be able to model the impact of the operating hardware on the total thermal performance in order to design the best windows possible and not let the operating hardware ruin an otherwise well-proven design, which is hence addressed in this study.Keywords
Funding Information
- U.S. Department of Energy (DE-AC02-05CH11231)
This publication has 22 references indexed in Scilit:
- Physical–chemical properties evolution and thermal properties reliability of a paraffin wax under solar radiation exposure in a real-scale PCM window systemEnergy and Buildings, 2016
- Impact of façade window design on energy, daylighting and thermal comfort in nearly zero-energy housesEnergy and Buildings, 2015
- Flow and heat transfer in double, triple and quadruple pane windowsEnergy and Buildings, 2015
- A state-of-the-art review on innovative glazing technologiesRenewable and Sustainable Energy Reviews, 2015
- Glazing systems with silica aerogel for energy savings in buildingsApplied Energy, 2012
- Key elements of and material performance targets for highly insulating window framesEnergy and Buildings, 2011
- Influence of window size on the energy balance of low energy housesEnergy and Buildings, 2006
- Performance rating of glass windows and glass windows with films in aspect of thermal comfort and heat transmissionEnergy and Buildings, 2005
- A simplified method to estimate energy savings of artificial lighting use from daylightingBuilding and Environment, 2005
- Optical and thermal characterization of multiple glazed windows with low U-valuesSolar Energy, 1994