Background: Combined esophageal high‐resolution impedance manometry (HRIM) measures multiple pressures and bolus transit simultaneously, facilitating detailed assessment of esophageal motility. Currently, normative values for water‐perfused HRIM systems for Chinese populations are lacking.Methods: Healthy volunteers were enrolled for comprehensive anthropometric measures, blood biochemistry tests, and an HRIM study using 22 water‐perfused pressure sensors and 12 impedance channels. Ten 5‐mL liquid swallows of saline at 30‐second intervals were conducted. The following parameters were calculated: distal contractile integral (DCI), distal latency (DL), lower esophageal sphincter (LES) basal pressure, 4‐second integrated relaxation pressure (IRP‐4s), and complete bolus transit percentage. Normal values were established based on the 5th and 95th percentiles.Key Results: All 66 participants (34 male, 32 female, aged 21‐64 years) completed the study and tolerated the HRIM procedure well. The upper normal limit (95th percentile) of IRP‐4 second was 20 mmHg. The 5th‐95th percentile range for DCI, DL, and complete bolus transit was 99‐2186 mmHg●s●cm, 6.2‐11.3 second, and 50%‐100%, respectively. Age was negatively correlated with DL. Females had significantly higher upper limits for IRP‐4s and median DCI than males. Multivariate analyses confirmed that IRP‐4s was higher in females, and that higher body mass index and waist circumference were associated with reduced DL and better bolus transit, respectively.Conclusions and Inferences: We established normative values for the water‐perfused HRIM system for a Chinese population. Gender and anthropometric factors may affect various major HRIM parameters and should be taken into account when interpreting HRIM results in clinical practice.Keywords
Funding Information
- National Taiwan University Hospital (NTUH. 105-S3024)
- Ministry of Science and Technology, Taiwan (MOST 103-2314-B-002-045-MY2, MOST 105-2325-B-002-041-)
This publication has 47 references indexed in Scilit:
- Normative data of high‐resolution impedance manometry in the Chinese populationJournal of Gastroenterology and Hepatology, 2013
- Influence of the catheter diameter on the investigation of the esophageal motility through solid-state high-resolution manometryDiseases of the Esophagus, 2013
- Chicago classification criteria of esophageal motility disorders defined in high resolution esophageal pressure topography1Neurogastroenterology & Motility, 2012
- Normative values and inter-observer agreement for liquid and solid bolus swallows in upright and supine positions as assessed by esophageal high-resolution manometryNeurogastroenterology & Motility, 2011
- Weak Peristalsis in Esophageal Pressure Topography: Classification and Association With DysphagiaAmerican Journal of Gastroenterology, 2011
- Esophageal Pressure Topography Criteria Indicative of Incomplete Bolus Clearance: A Study Using High-Resolution Impedance ManometryAmerican Journal of Gastroenterology, 2009
- Ethnic variation in lower oesophageal sphincter pressure and lengthAlimentary Pharmacology & Therapeutics, 2008
- Esophageal Motility Disorders in Terms of Pressure TopographyJournal of Clinical Gastroenterology, 2008
- The Reflux Disease Questionnaire: a measure for assessment of treatment response in clinical trialsHealth and Quality of Life Outcomes, 2008
- Pressure tension, and force of closure of the human lower esophageal sphincter and esophagus.Journal of Clinical Investigation, 1975