Position of Interbody Spacer in Transforaminal Lumbar Interbody Fusion: Effect on 3-dimensional Stability and Sagittal Lumbar Contour
Authors:
- Antonio A. FaundezAFAntonio A. Faundez
- Amir A. MehbodAMAmir A. Mehbod
- Chunhui WuCWChunhui Wu
- Wentien WuWWWentien Wu
- Avraam PloumisAPAvraam Ploumis
- Ensor E. TransfeldtETEnsor E. Transfeldt
- 1 May 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 21 (3) , 175-180
Abstract
Biomechanical study. To test 2 different intervertebral positions of a semilunar cage and their effects on 3-dimensional stability and segmental lordosis in a model of transforaminal lumbar interbody fusion (TLIF). In his original TLIF description, Harms recommended decortication of endplates, followed by placement of mesh cages in the middle-posterior intervertebral third. Subsequent studies presented conflicting recommendations: anterior placement of the spacer-cage for better load-sharing versus placement on the stronger posterolateral endplate regions. Six human lumbar spinal functional units were first tested intact. TLIF was performed using a semilunar poly-ether-ether-ketone cage randomly inserted in the anterior (TLIF-A) or posterior (TLIF-P) disc space. Pedicle screws and rods were added. Unconstrained pure moments in axial-torsion, lateral-bending (LB), and flexion-extension (FE) were applied under 0.05 Hz and +/-5 Nm sinusoidal waveform. Segmental motions were recorded. Range of motion (ROM) and neutral zone (NZ) were calculated. Pairwise comparisons were made using nonparametric Wilcoxon-matched pairs signed rank sum test with statistical significance set at P0.05). Delta-ROM between TLIF-A and TLIF-P was not significant (P>0.05). TLIF-A and TLIF-P significantly decreased NZ in LB (P0.05). Segmental lordosis of TLIF-A and TLIF-P on C-arm views showed angle differences within the range of measurement error of Cobb angles. Difference in ROM and NZ between anterior (TLIF-A) or posterior (TLIF-P) positions was not statistically significant. Similarly, both positions did not influence segmental lordosis.Keywords
This publication has 35 references indexed in Scilit:
- Transforaminal Lumbar Interbody FusionJournal of Spinal Disorders & Techniques, 2005
- Vascular injury during anterior lumbar surgery*1The Spine Journal, 2004
- Computerized tomography evaluation of a resorbable implant after transforaminal lumbar interbody fusionNeurosurgical Focus, 2004
- Transforaminal lumbar interbody fusionOrthopedic Clinics of North America, 2002
- Unilateral Transforaminal Posterior Lumbar Interbody Fusion (TLIF): Indications, Technique, and 2-Year ResultsJournal of Spinal Disorders & Techniques, 2002
- Anterior/Posterior Lumbar Fusion Versus Transforaminal Lumbar Interbody Fusion: Analysis of Complications and Predictive FactorsJournal of Spinal Disorders, 2001
- Comparison of Posterior and Transforaminal Approaches to Lumbar Interbody FusionSpine, 2001
- Retrograde ejaculation after retroperitoneal lower lumbar interbody fusionInternational Orthopaedics, 1997
- Ureteral Injury After Anterior Lumbar Interbody FusionSpine, 1996
- Vascular Injury in Anterior Lumbar SurgerySpine, 1993