Robust optimization of VMAT for prostate cancer accounting for geometric uncertainty
Open Access
- 3 August 2022
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (9) , e13738
Abstract
The aim of this study was to propose optimal robust planning by comparing the robustness with setup error with the robustness of a conventional planning target volume (PTV)‐based plan and to compare the robust plan to the PTV‐based plan for the target and organ at risk (OAR). Data from 13 patients with intermediate‐to‐high‐risk localized prostate cancer who did not have T3b disease were analyzed. The dose distribution under multiple setup error scenarios was assessed using a conventional PTV‐based plan. The clinical target volume (CTV) and OAR dose in moving coordinates were used for the dose constraint with the robust plan. The hybrid robust plan added the dose constraint of the PTV‐rectum to the static coordinate system. When the isocenter was shifted by 10 mm in the superior–inferior direction and 8 mm in the right‐left and anterior directions, the doses to the CTV, bladder, and rectum of the PTV‐based plan, robust plan, and hybrid robust plan were compared. For the CTV D99% in the PTV‐based plan and hybrid robust plan, over 95% of the prescribed dose was secured in all directions, except in the inferior direction. There was no significant difference between the PTV‐based plan and the hybrid robust plan for rectum V70Gy, V60Gy, and V40Gy. This study proposed an optimization method for patients with prostate cancer. When the setup error occurred within the PTV margin, the dose robustness of the CTV for the hybrid robust plan was higher than that of the PTV‐based plan, while maintaining the equivalent OAR dose.Keywords
This publication has 21 references indexed in Scilit:
- Evaluation of RayStation robust optimisation for superficial target coverage with setup variation in breast IMRTAustralasian Physics & Engineering Sciences in Medicine, 2016
- Robust optimization methods for cardiac sparing in tangential breast IMRTMedical Physics, 2015
- Preliminary Toxicity Analysis of 3-Dimensional Conformal Radiation Therapy Versus Intensity Modulated Radiation Therapy on the High-Dose Arm of the Radiation Therapy Oncology Group 0126 Prostate Cancer TrialInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Potentials of robust intensity modulated scanning proton plans for locally advanced lung cancer in comparison to intensity modulated photon plansRadiotherapy and Oncology, 2012
- Minimax optimization for handling range and setup uncertainties in proton therapyMedical Physics, 2011
- Application of a Novel Dose-Uncertainty Model for Dose-Uncertainty Analysis in Prostate Intensity-Modulated RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Dose–volume effects for normal tissues in external radiotherapy: PelvisRadiotherapy and Oncology, 2009
- Incorporating organ movements in IMRT treatment planning for prostate cancer: Minimizing uncertainties in the inverse planning processMedical Physics, 2005
- The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2000
- Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probabilityInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1999