Evaluating the Biostability of Yellow and Clear Intraocular Lenses with a System Simulating Natural Intraocular Environment
Authors:
Open Access
- 1 November 2016
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 5 (6) , 11
Abstract
Purpose: Blue light–filtering intraocular lenses (IOLs) are thought to protect the retina from blue light damage after cataract surgery, and the implantation of yellow-tinted IOLs has been commonly used in cataract surgery. To our knowledge, this is the first investigation measuring the long-term biostability of yellow-tinted IOLs using an in vitro system simulating natural intraocular environment. Methods: Six hydrophobic acrylic IOLs, three clear IOLs, and three yellow-tinted IOLs were included in the study. Each yellow-tinted IOL was a matching counterpart of a clear IOL, with the only difference being the lens color. The IOLs were kept in conditions replicating the intraocular environment using a perfusion culture system for 7 months. Resolution, light transmittance rate, and the modulation transfer function (MTF) were measured before and after culturing. Surface roughness of the anterior and posterior surfaces was also measured. Results: After culturing for 7 months, there were no changes in the resolution, the light transmittance rate, and MTF. The surface roughness of the anterior and posterior surfaces increased after culturing; however, this increase was clinically insignificant. There were no differences in surface roughness between the clear and yellow-tinted IOLs, either before or after culturing. Conclusions: A novel in vitro system replicating intraocular environment was used to investigate the biostability of yellow-tinted IOLs. The surface roughness showed no clinically significant increase after culturing for 7 months. Translational Relevance: This system is useful for evaluating the biostability of IOLs.Keywords
This publication has 17 references indexed in Scilit:
- Photoprotective effect of yellow-tinted intraocular lensesJapanese Journal of Ophthalmology, 2009
- Mitochondria-derived Reactive Oxygen Species Mediate Blue Light–induced Death of Retinal Pigment Epithelial Cells¶Photochemistry and Photobiology, 2004
- Surface roughness of intraocular lenses and inflammatory cell adhesion to lens surfacesJournal of Cataract & Refractive Surgery, 2003
- The Association of Cataract and Cataract Surgery With the Long-term Incidence of Age-Related MaculopathyArchives of Ophthalmology (1950), 2002
- Blood–retinal barrier and autofluorescence of the posterior polar retina in long-standing pseudophakiaJournal of Cataract & Refractive Surgery, 1999
- Postoperative inflammatory response to phacoemulsification and extracapsular cataract surgery: Aqueous flare and cellsJournal of Cataract & Refractive Surgery, 1996
- Natural history of cellular deposits on the anterior intraocular lens surfaceJournal of Cataract & Refractive Surgery, 1995
- [Spectral transmittance of normal human crystalline lens].1994
- Corneal cell adhesion and proliferation on hydrogel sheets bound with cell-adhesive proteinsCurrent Eye Research, 1991
- Ultraviolet radiation protection.1985