Elastomeric surgical sealant for hemostasis of cardiovascular anastomosis under full heparinization
Authors:
- 1 November 2007
- journal article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 32 (5) , 730-734
Abstract
We developed a novel surgical sealant, a viscous diisocyanated prepolymer, applicable to arterial hemostasis. The purpose of this study is to evaluate hemostatic effect of this surgical sealant under heparinized conditions. The effectiveness of this sealant was verified by applying it to the end-to-end anastomosis of canine carotid arteries. Five mongrel dogs were used. After a complete heparinization, the carotid arteries were clamped, divided, and end-to-end anastomoses were performed with four simple interrupted sutures. The sealant was coated on the anastomosis. After 5 min the clamps were removed and the hemostatic effect was evaluated. Three dogs were immediately subjected to macroscopic evaluation. Two dogs were subjected to angiography after 3 months and 16 months, respectively. No bleeding occurred in any of the anastomoses immediately after the removal of the clamp. Macroscopic finding revealed no leakage of the sealant into the lumen. Carotid angiography revealed patent anastomoses without stenosis. A novel surgical sealant exhibited rapid and potent hemostatic effect on a moisturized tissue under full heparinization.Keywords
This publication has 9 references indexed in Scilit:
- Absorbable Cyanoacrylate as a Vascular Hemostatic Sealant: A Preliminary TrialThe American Surgeon™, 2005
- BioGlue surgical adhesive—an appraisal of its indications in cardiac surgeryThe Annals of Thoracic Surgery, 2002
- A Polymeric Sealant Inhibits Anastomotic Suture Hole Bleeding More Rapidly Than Gelfoam/ThrombinResults of a Randomized Controlled TrialArchives of Surgery, 2002
- Treatment of suture line bleeding with a novel synthetic surgical sealant in a canine iliac PTFE graft modelJournal of Biomedical Materials Research, 2001
- Sutureless coronary artery bypass with biologic glued anastomoses: Preliminary in vivo and in vitro resultsThe Journal of Thoracic and Cardiovascular Surgery, 2000
- Sutureless anastomosis of blood vessels using cyanoacrylate adhesivesSurgery Today, 1992
- Four years' experience with fibrin sealant in thoracic and cardiovascular surgeryThe Annals of Thoracic Surgery, 1990
- Development of a Compliant Surgical Adhesive Derived from Novel Fluorinated Hexamethylene DiisocyanateASAIO Transactions, 1989
- Randomized clinical trial of fibrin sealant in patients undergoing resternotomy or reoperation after cardiac operationsThe Journal of Thoracic and Cardiovascular Surgery, 1989