Correction for non‐perpendicularity of beam and tilt axis in tomographic reconstructions with the IMOD package
- 25 April 2008
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 230 (2) , 212-217
Abstract
Summary: A correction for non‐perpendicularity between the beam axis and the tilt axis in electron tomographic tilt series has been implemented in the IMOD software package and its value and limitations have been explored. Correction for this effect can provide a significant improvement in the alignment error and the reconstruction quality in some cases. However, when the projection model being fit includes an anisotropic shrinkage (i.e. stretch) in the plane of the specimen, adding a variable for the beam tilt does not produce a lower alignment error; it is thus not possible to distinguish between the effects of stretch and beam tilt. Test reconstructions indicate that an alignment solution that includes stretch will adequately correct for the effects of a beam tilt. For specimens subject to deformation under the beam, an alignment solution that accounts for stretch is preferable to one that accounts for beam tilt instead, provided that the markers used for alignment are sufficiently well distributed. Otherwise, a correction for beam tilt should be used.Keywords
This publication has 13 references indexed in Scilit:
- Alignment of fiducial marks in a tomographic tilt series with an unknown rotation axisComputer Physics Communications, 2007
- Tilt-series and electron microscope alignment for the correction of the non-perpendicularity of beam and tilt-axisJournal of Structural Biology, 2006
- New views of cells in 3D: an introduction to electron tomographyTrends in Cell Biology, 2005
- Conical tomography of freeze-fracture replicas: a method for the study of integral membrane proteins inserted in phospholipid bilayersJournal of Structural Biology, 2005
- Dual-Axis Tomography: An Approach with Alignment Methods That Preserve ResolutionJournal of Structural Biology, 1997
- Variable Metric Function MinimizationJournal of the Royal Statistical Society Series C: Applied Statistics, 1997
- Computer Visualization of Three-Dimensional Image Data Using IMODJournal of Structural Biology, 1996
- Double-tilt electron tomographyUltramicroscopy, 1995
- Least-Squares Method of Alignment Using Markers1992
- The reconstruction of a three-dimensional structure from projections and its application to electron microscopyProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1970