Abstract
The aim of the study was to investigate the usefulness of processing visual field (VF) using a variational autoencoder (VAE). The training data consisted of 82,433 VFs from 16,836 eyes. Testing dataset 1 consisted of test-retest VFs from 104 eyes with open angle glaucoma. Testing dataset 2 was series of 10 VFs from 638 eyes with open angle glaucoma. A VAE model to reconstruct VF was developed using the training dataset. VFs in the testing dataset 1 were then reconstructed using the trained VAE and the mean total deviation (mTD) was calculated (mTDVAE). In testing dataset 2, the mTD value of the tenth VF was predicted using shorter series of VFs. A similar calculation was carried out using a weighted linear regression where the weights were equal to the absolute difference between mTD and mTDVAE. In testing dataset 1, there was a significant relationship between the difference between mTD and mTDVAE from the first VF and the difference between mTD in the first and second VFs. In testing dataset 2, mean squared prediction errors with the weighted mTD trend analysis were significantly smaller than those form the unweighted mTD trend analysis.Keywords
This publication has 54 references indexed in Scilit:
- Detection of Progression of Glaucomatous Visual Field Damage Using the Point-Wise Method with the Binomial TestPLOS ONE, 2013
- Identifying Areas of the Visual Field Important for Quality of Life in Patients with GlaucomaPLOS ONE, 2013
- Rates of visual field progression in clinical glaucoma careActa Ophthalmologica, 2012
- The Relationship between Variability and Sensitivity in Large-Scale Longitudinal Visual Field DataInvestigative Ophthalmology & Visual Science, 2012
- A Method to Measure and Predict Rates of Regional Visual Field Decay in GlaucomaInvestigative Ophthalmology & Visual Science, 2011
- On the accuracy of measuring rates of visual field change in glaucomaBritish Journal of Ophthalmology, 2010
- Assessment of False Positives with the Humphrey Field Analyzer II Perimeter with the SITA AlgorithmInvestigative Ophthalmology & Visual Science, 2006
- Prediction of Visual Field Progression in GlaucomaInvestigative Ophthalmology & Visual Science, 2004
- Interobserver agreement on visual field progression in glaucoma: a comparison of methodsBritish Journal of Ophthalmology, 2003
- Association of reliability with reproducibility of the glaucomatous visual fieldActa Ophthalmologica, 1992