Emission Characteristics of PM (PMtotal, PM10, PM2.5), NOx, CO and VOCs Emitted from LNG-fired Gas Turbine and Small Domestic Boiler
Authors:
- JongHyeon KimJKJongHyeon Kim
- JeongHun YuJYJeongHun Yu
- Jihan SongJSJihan Song
- DoYoung LeeDLDoYoung Lee
- MyeongSang YuMYMyeongSang Yu
- InJun HwangIHInJun Hwang
- JinSung KimJKJinSung Kim
- JongHo KimJKJongHo Kim
Open Access
- 17 December 2021
- journal article
- research article
- Published by Springer Nature in Asian Journal of Atmospheric Environment
- Vol. 15 (4)
Abstract
In recent years, natural gas is increasingly being used in the heating and power generation sectors as a clean fuel with an aim to reduce air pollution. In this study, a standard test method was used to measure air pollutants and identify emission characteristics for gas turbines and small domestic boilers, which use LNG as fuel. For gas turbines, the air pollutants were measured at 14 sites, whereas for small domestic boilers, six of them were installed in a laboratory to run tests due to limitations in on-site measuring and testing. However, the small domestic boilers were all new machines and were operated for long consecutive hours for testing, meaning that the results could vary from that of on-site boilers. The results show that gas turbines and small domestic boilers not only emit PM2.5, but also particulate matters larger than PM2.5. According to the measurements, the average concentration level of PMtotal, PM10, and PM2.5 generated from gas turbines are 51.8, 38.5, and 28.1 µg/m3 (@O2 15%), respectively. Those generated from small domestic boilers were 31.3, 26.2, and 20.0 µg/m3 (@O2 4%), respectively. The NOx concentration levels complied with the emission limits. Especially where a NOx control device was in place, both the NOx and CO concentration levels were relatively low. However, the NOx and CO concentration levels were generated from small domestic boilers were relatively high, since the emission limits were not applied. VOCs were measured at 10 facilities where 28 samples were collected. The compounds that were identified were Aromatics, Oxygenated VOCs, Alkanes, in that order, which were consistent across the samples. Aromatics consisted mostly of toluene, o,m,p-xylenes, benzene, and ethylbenzene. Among oxygenated VOCs, ethyl acetate, vinyl acetate, and isopropyl alcohol, etc. were identified. In other words, gas turbines generated a wider range and higher concentration levels of VOCs compared to small domestic boilers. The emission factors of gas turbines and small domestic boilers were derived from the measurements, and then compared with the standard emission factors of other countries (NAER, U.S. EPA AP-42, EMEP/EEA). PM emission factors calculated in this study were lower than that of existing emission factors and the calculated NOx emission factors (uncontrolled) for the small boilers were also lower. The CO emission factor for gas turbines was lower than that of existing emission factors, but higher for the small domestic boilers. Emission factors of benzene, toluene, and xylenes, which are hazardous air pollutants, were lower than those of U.S. EPA AP-42.Keywords
Funding Information
- Korea Environmental Industry and Technology Institute
This publication has 15 references indexed in Scilit:
- Critical review of condensable particulate matterFuel, 2018
- Characteristics of long-term behavior of VOC species in Korea : PAMS data analysisJournal of Korean Society for Atmospheric Environment, 2018
- Photochemical ozone creation potentials for volatile organic compounds: Rationalization and estimationAtmospheric Environment, 2017
- The Characterization of PM, PM10, and PM2.5from Stationary SourcesJournal of Korean Society for Atmospheric Environment, 2016
- PM2.5 and ultrafine particulate matter emissions from natural gas-fired turbine for power generationAtmospheric Environment, 2016
- Management Changes of Hazardous Air Pollutants Sources and Its Proposed Improvement in KoreaJournal of Korean Society for Atmospheric Environment, 2013
- Secondary organic aerosol formation from a large number of reactive man-made organic compoundsScience of The Total Environment, 2010
- Evaluation of Gas, Oil and Wood Pellet Fueled Residential Heating System Emissions Characteristics2009
- Air Quality in the Mexico Megacity2002
- In-Stack Condensible Particulate Matter Measurements and IssuesJournal of the Air & Waste Management Association, 2000