Utility of a Spring-loaded Blunt-tip Co-axial Needle in Accessing "Difficult-to-reach" Targets during Percutaneous Image-guided Procedures
Authors:
Open Access
- 21 October 2025
- journal article
- Published by The Japanese Society of Interventional Radiology in Interventional Radiology
- Vol. 10, e2025-0027
Abstract
Purpose: To review the utility of a spring-loaded blunt-tip co-axial needle in improving procedural outcomes when accessing "difficult-to-reach" targets during percutaneous image-guided procedures.Material and Methods: In this single-center retrospective study, consecutive adult patients who underwent percutaneous image-guided procedures using a spring-loaded blunt-tip co-axial needle for "difficult-to-reach" targets from January 2021 to December 2024 were reviewed. Clinical information, including demographics and medical history, was recorded. Pre- and post-procedural radiological findings were assessed. Procedural details, modality of image guidance, technical success, and complications were analyzed. Post-procedural follow-up was reviewed.Results: A total of 21 patients (median age: 68.0 years, range 33.0-88.0 years; 15 [71.4%] male) were included. Nearly half (n = 10, 47.6%) of the procedures were percutaneous image-guided drainage. One-third (n = 7, 33.3%) were hydrodissection performed for radiofrequency or microwave ablation of tumors. Three (14.3%) were image-guided biopsies. In one patient (4.8%), the needle was used for percutaneous embolization of a type II endoleak after endovascular repair of an enlarging internal iliac artery aneurysm. No procedure-related complication was encountered. In all 21 cases, adjacent organs were avoided, resulting in retained drainage, achieved tumor control with ablation, achieved tissue diagnosis with biopsy, and eliminated endoleak (100% technical success).Conclusions: The spring-loaded blunt-tip co-axial needle appeared to be useful in accessing "difficult-to-reach" targets in a variety of percutaneous image-guided procedures, including drainage, hydrodissection, biopsy, and percutaneous embolization of endoleak.Keywords
This publication has 14 references indexed in Scilit:
- CIRSE Standards of Practice on Management of Endoleaks Following Endovascular Aneurysm RepairCardioVascular and Interventional Radiology, 2024
- Safety profile and technical success of narrow window CT-guided percutaneous biopsy with blunt needle approach in the abdomen and pelvisEuropean Radiology, 2023
- Cervical spine tenosynovial giant cell tumor involving the atlantoaxial joint in a pediatric patient with medulloblastomaSkeletal Radiology, 2021
- CIRSE Clinical Practice ManualCardioVascular and Interventional Radiology, 2021
- CIRSE Standards of Practice on Thermal Ablation of Liver TumoursCardioVascular and Interventional Radiology, 2020
- Preclinical evaluation of the atraumatic nature of a spring loaded blunt tip coaxial needle in a swine modelDiagnostic and Interventional Imaging, 2019
- Cirse Quality Assurance Document and Standards for Classification of Complications: The Cirse Classification SystemCardioVascular and Interventional Radiology, 2017
- CIRSE Guidelines on Percutaneous Needle Biopsy (PNB)CardioVascular and Interventional Radiology, 2017
- Performance of a New Blunt-Tip Coaxial Needle for Percutaneous Biopsy and Drainage of “Hard-To-Reach” TargetsCardioVascular and Interventional Radiology, 2017
- Cardiovascular and Interventional Radiological Society of Europe Guidelines on Endovascular Treatment in Aortoiliac Arterial DiseaseCardioVascular and Interventional Radiology, 2013