Measurements of alveolar concentrations of toluene
Authors:
- 1 April 1984
- journal article
- research article
- Published by Springer Nature in International Archives of Occupational and Environmental Health
- Vol. 54 (1) , 65-71
Abstract
The use of a photoionisationdetector (PID) for measurement of alveolar concentrations of gases and vapours was evaluated during a human exposure experiment with toluene. Two other methods, the standard gas-pipette method and the gasbag/charcoal method, was tested for comparison. The best method appeared to be the PID-method. The major disadvantage in using this instrument was the missing selectivity towards individual compounds in a mixed atmosphere. In all other respects, the method is just as good as or better than the standard gaspipette method and the gasbag method. Results from 40 measurements with the three methods on 16 persons were examined statistically, and the average toluene absorption at 100 ppm exposure levels was estimated to be 1.6 mg/min.Keywords
This publication has 6 references indexed in Scilit:
- Human response to controlled levels of toluene in six-hour exposures.Scandinavian Journal of Work, Environment & Health, 1983
- Experimental human exposure to tolueneInternational Archives of Occupational and Environmental Health, 1978
- Evaluation of glass sampling tubes for industrial breath analysisAIHA Journal, 1978
- Evaluation of a new photoionization detector for organic compoundsJournal of Chromatography A, 1977
- Use of breath analysis to monitor methylene chloride exposure.Scandinavian Journal of Work, Environment & Health, 1976
- The Measurement of Occupational Exposure to Benzene VapourAnnals of Occupational Hygiene, 1970