A Retrospective Study of Success, Failure, and Time Needed to Perform Awake Intubation
Open Access
- 1 July 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 125 (1) , 105-114
Abstract
This large retrospective analyses of 1,085 awake intubations performed in an academic hospital revealed that awake fiberoptic intubation added approximately 8 min of time in the operating room compared to asleep intubation techniques. Awake intubation was successfully performed with low failure rate (1%) and low complication rate (1.6%) under hemodynamically stable conditions. Background: Awake intubation is the standard of care for management of the anticipated difficult airway. The performance of awake intubation may be perceived as complex and time-consuming, potentially leading clinicians to avoid this technique of airway management. This retrospective review of awake intubations at a large academic medical center was performed to determine the average time taken to perform awake intubation, its effects on hemodynamics, and the incidence and characteristics of complications and failure. Methods: Anesthetic records from 2007 to 2014 were queried for the performance of an awake intubation. Of the 1,085 awake intubations included for analysis, 1,055 involved the use of a flexible bronchoscope. Each awake intubation case was propensity matched with two controls (1:2 ratio), with similar comorbidities and intubations performed after the induction of anesthesia (n = 2,170). The time from entry into the operating room until intubation was compared between groups. The anesthetic records of all patients undergoing awake intubation were also reviewed for failure and complications. Results: The median time to intubation for patients intubated post induction was 16.0 min (interquartile range: 13 to 22) from entrance into the operating room. The median time to intubation for awake patients was 24.0 min (interquartile range: 19 to 31). The complication rate was 1.6% (17 of 1,085 cases). The most frequent complications observed were mucous plug, endotracheal tube cuff leak, and inadvertent extubation. The failure rate for attempted awake intubation was 1% (n = 10). Conclusions: Awake intubations have a high rate of success and low rate of serious complications and failure. Awake intubations can be performed safely and rapidly.Keywords
This publication has 29 references indexed in Scilit:
- Practice Guidelines for Management of the Difficult AirwayAnesthesiology, 2013
- Patientsʼ experience of awake versus anaesthetised orotracheal intubation: a controlled studyEuropean Journal of Anaesthesiology, 2011
- Routine Clinical Practice Effectiveness of the Glidescope in Difficult Airway ManagementAnesthesiology, 2011
- The effectiveness of dexmedetomidine infusion for sedating oral cancer patients undergoing awake fibreoptic nasal intubationEuropean Journal of Anaesthesiology, 2010
- Atomised lidocaine for airway topical anaesthesia in the morbidly obese: 1% compared with 2%*Anaesthesia, 2009
- Spray-As-You-Go Airway Topical Anesthesia in Patients with a Difficult Airway: A Randomized, Double-Blind Comparison of 2% and 4% LidocaineAnesthesia & Analgesia, 2009
- Airway topicalisation in morbidly obese patients using atomised lidocaine: 2% compared with 4%*Anaesthesia, 2007
- Task Analysis of the Preincision Surgical Period: An Independent Observer-Based Study of 1558 CasesAnesthesia & Analgesia, 2006
- Production Pressure in the Work EnvironmentAnesthesiology, 1994
- Additional Safety Measures When Changing Endotracheal TubesAnesthesiology, 1991