Rapid and accurate left ventricular chamber quantification using a novel CMR segmentation algorithm: A clinical validation study
Authors:
- Richard WongRWRichard Wong
- Martin R. PrinceMartin R. Prince
- Jonathan W. WeinsaftJWJonathan W. Weinsaft
Open Access
- 29 March 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 31 (4) , 845-853
Abstract
Purpose: To evaluate the clinical performance of a novel automated left ventricle (LV) segmentation algorithm (LV-METRIC) that involves no geometric assumptions. Materials and Methods: LV-METRIC and manual tracing (MT) were used independently to quantify LV volumes and LVEF (ejection fraction) for 151 consecutive patients who underwent cine-CMR (steady-state free precession). Phase contrast imaging was used to independently measure stroke volume. Results: LV-METRIC was successful in all cases. Mean LVEF was within 1 point of MT (Δ 0.6 ± 2.3%, P < 0.05), with smaller differences among patients with (0.5 ± 2.5%) versus those without (0.9 ± 2.3%; P = 0.01) advanced systolic dysfunction (LVEF ≤ 35% by MT). LV volumes by LV-METRIC were slightly smaller than MT during end-diastole (3.9 ± 6.8 mL, P < 0.001) and end-systole (1.4 ± 5.5 mL, P < 0.01). Mean processing time was 22 ± 13 seconds for LV-METRIC and 4:59 ± 1:56 minutes for MT (P < 0.001). Processing time correlated with LV blood volume by MT (r = 0.43) and LV-METRIC (r = 0.55), but slope was 10-fold steeper for MT (0.02 vs. 0.001), indicating greater proportionate time increases in relation to chamber dilation. Compared to stroke volume by phase contrast, LV-METRIC yielded smaller differences (0.3 ± 18.3 mL) than MT (2.5 ± 17.2 mL; P < 0.001). Conclusion: Among a broad series of consecutive patients undergoing CMR, automated LVEF by LV-METRIC was within 1 point of MT with processing time reduced 14-fold. Stroke volume by LV-METRIC yielded improved agreement with an independent standard of phase contrast imaging. J. Magn. Reson. Imaging 2010;31:845–853. ©2010 Wiley-Liss, Inc.Keywords
This publication has 34 references indexed in Scilit:
- Effects of papillary muscles and trabeculae on left ventricular quantification: increased impact of methodological variability in patients with left ventricular hypertrophyJournal Of Hypertension, 2008
- Automatic computation of left ventricular ejection fraction from spatiotemporal information in cine‐SSFP cardiac MR imagesJournal of Magnetic Resonance Imaging, 2008
- Quantitative comparison of 2D and 3D circumferential strain using MRI tagging in normal and LBBB heartsMagnetic Resonance in Medicine, 2007
- Traditional Cardiovascular Risk Factors in Relation to Left Ventricular Mass, Volume, and Systolic Function by Cardiac Magnetic Resonance ImagingJACC, 2006
- Left Ventricular Hypertrophy Is More Prevalent in Blacks Than Whites in the General PopulationHypertension, 2005
- Segmentation of 4D cardiac MR images using a probabilistic atlas and the EM algorithmMedical Image Analysis, 2004
- Automated segmentation of the left ventricle in cardiac MRIMedical Image Analysis, 2004
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionThe New England journal of medicine, 2002
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Assessment of left ventricular pressure-volume relations using gated radionuclide angiography, echocardiography, and micromanometer pressure recordings. A new method for serial measurements of systolic and diastolic function in man.Circulation, 1983