The effects of kinematically aligned total knee arthroplasty on stress at the medial tibia
Authors:
Open Access
- 1 January 2017
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 6 (1) , 43-51
Abstract
Objectives: Little biomechanical information is available about kinematically aligned (KA) total knee arthroplasty (TKA). The purpose of this study was to simulate the kinematics and kinetics after KA TKA and mechanically aligned (MA) TKA with four different limb alignments. Materials and Methods: Bone models were constructed from one volunteer (normal) and three patients with three different knee deformities (slight, moderate and severe varus). A dynamic musculoskeletal modelling system was used to analyse the kinematics and the tibiofemoral contact force. The contact stress on the tibial insert, and the stress to the resection surface and medial tibial cortex were examined by using finite element analysis. Results: In all bone models, posterior translation on the lateral side and external rotation in the KA TKA models were greater than in the MA TKA models. The tibiofemoral force at the medial side was increased in the moderate and severe varus models with KA TKA. In the severe varus model with KA TKA, the contact stress on the tibial insert and the stress to the resection surface and to the medial tibial cortex were increased by 41.5%, 32.2% and 53.7%, respectively, compared with MA TKA, and the bone strain at the medial side was highest among all models. Conclusion: Near normal kinematics was observed in KA TKA. However, KA TKA increased the contact force, stress and bone strain at the medial side for moderate and severe varus knee models. The application of KA TKA for severe varus knees may be inadequate. Cite this article: S. Nakamura, Y. Tian, Y. Tanaka, S. Kuriyama, H. Ito, M. Furu, S. Matsuda. The effects of kinematically aligned total knee arthroplasty on stress at the medial tibia: A case study for varus knee. Bone Joint Res 2017;6:43–51. DOI: 10.1302/2046-3758.61.BJR-2016-0090.R1.Keywords
This publication has 34 references indexed in Scilit:
- Effect of tibial component varus on wear in total knee arthroplastyThe Knee, 2012
- The Chitranjan Ranawat Award: Is Neutral Mechanical Alignment Normal for All Patients?: The Concept of Constitutional VarusClinical Orthopaedics and Related Research, 2012
- Structural Properties of the Primary Medial Knee LigamentsThe American Journal of Sports Medicine, 2010
- A biomechanical assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurementsJournal of Orthopaedic Surgery and Research, 2010
- Fluoroscopic and Computed Tomographic Analysis of Knee Kinematics During Very Deep Flexion After Total Knee ArthroplastyThe Journal of Arthroplasty, 2010
- Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?Clinical Orthopaedics and Related Research, 2010
- Comparing Patient Outcomes After THA and TKA: Is There a Difference?Clinical Orthopaedics and Related Research, 2009
- Coronal Alignment in Total Knee ArthroplastyThe Journal of Arthroplasty, 2009
- The effect of valgus/varus malalignment on load distribution in total knee replacementsJournal of Biomechanics, 2005
- Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplastyBiomaterials, 1999