A machine learning-based model for a dose point kernel calculation
Open Access
- 26 June 2023
- journal article
- research article
- Published by Springer Nature in EJNMMI Physics
- Vol. 10 (1) , 1-18
Abstract
Purpose: Absorbed dose calculation by kernel convolution requires the prior determination of dose point kernels (DPK). This study reports on the design, implementation, and test of a multi-target regressor approach to generate the DPKs for monoenergetic sources and a model to obtain DPKs for beta emitters.Methods: DPK for monoenergetic electron sources were calculated using the FLUKA Monte Carlo (MC) code for many materials of clinical interest and initial energies ranging from 10 to 3000 keV. Regressor Chains (RC) with three different coefficients regularization/shrinkage models were used as base regressors. Electron monoenergetic scaled DPKs (sDPKs) were used to assess the corresponding sDPKs for beta emitters typically used in nuclear medicine, which were compared against reference published data. Finally, the beta emitters sDPK were applied to a patient-specific case calculating the Voxel Dose Kernel (VDK) for a hepatic radioembolization treatment with $$^{90}$$ Y.Results: The three trained machine learning models demonstrated a promising capacity to predict the sDPK for both monoenergetic emissions and beta emitters of clinical interest attaining differences lower than $$10\%$$ in the mean average percentage error (MAPE) as compared with previous studies. Furthermore, differences lower than $$7 \%$$ were obtained for the absorbed dose in patient-specific dosimetry comparing against full stochastic MC calculations.Conclusion: An ML model was developed to assess dosimetry calculations in nuclear medicine. The implemented approach has shown the capacity to accurately predict the sDPK for monoenergetic beta sources in a wide range of energy in different materials. The ML model to calculate the sDPK for beta-emitting radionuclides allowed to obtain VDK useful to achieve reliable patient-specific absorbed dose distributions required short computation times.
Keywords
All Related Versions
This publication has 69 references indexed in Scilit:
- A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codesMedical Physics, 2012
- Support Vector Machines for classification and regressionThe Analyst, 2009
- Using single- and multi-target regression trees and ensembles to model a compound index of vegetation conditionEcological Modelling, 2009
- PREFACEAnnals of the ICRP, 2008
- Systemic radionuclide therapy in pain palliationAmerican Journal of Hospice and Palliative Medicine®, 2005
- Regularization and Variable Selection Via the Elastic NetJournal of the Royal Statistical Society Series B: Statistical Methodology, 2005
- Adaptation of GEANT4 to Monte Carlo dose calculations based on CT dataMedical Physics, 2004
- Beta voxel S values for internal emitter dosimetryMedical Physics, 2003
- Basic anatomical and physiological data for use in radiological protection: reference valuesAnnals of the ICRP, 2002
- An improved multiple scattering model for charged particle transportNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1992