Versatile Gas Detection System Based on Combined NDIR Transmission and Photoacoustic Absorption Measurements
- 11 October 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 13 (3) , 934-940
Abstract
Based on a low-cost micro-machined infrared (IR) source with subsequent gas specific filter, photoacoustic absorption (PA) measurements were investigated in a nonresonant operating mode of a gas cell. In addition, nondispersive IR (NDIR) transmission measurements based on a thermopile detector were used to expand the measurement range, but also for an inherent self-monitoring scheme of the system. Compared to other systems using expensive laser sources for stimulation of acoustic pressure waves in a resonant mode of operation, the approach is based on low-cost components. The IR source was modulated in the frequency range between 1 and 10 Hz. To achieve enhanced resolution and a good signal to noise ratio the sensor raw data-both for transmission as well as absorption measurements-were evaluated using discrete Fourier transformation. By combining PA and NDIR transmission measurements a wide concentration range is achieved, e.g., 100-20 000 ppm of carbon dioxide for a measurement cell with a length of 9 cm. Whereas the NDIR transmission measurement is suitable for monitoring higher concentrations, the PA measurement offers better detectivity at lower gas concentrations. Furthermore, the modular system allows the realization of a self-monitoring scheme by comparing the signals measured with both approaches, thus omitting the need for a second filter at a reference wavelength.Keywords
This publication has 10 references indexed in Scilit:
- Versatile infrared gas measurement system with tunable microstructured Fabry-Pérot Filter2012
- Tunable infrared detector with integrated micromachined Fabry-Perot filterJournal of Micro/Nanolithography, MEMS, and MOEMS, 2008
- Energy and Material Balance of CO2 Capture from Ambient AirEnvironmental Science & Technology, 2007
- Photoacoustic spectroscopy for process analysisAnalytical and Bioanalytical Chemistry, 2005
- Identification of Organic Solvents by a Virtual Multisensor System With Hierarchical ClassificationIEEE Sensors Journal, 2004
- High performance solvent vapor identification with a two sensor array using temperature cycling and pattern classificationSensors and Actuators B: Chemical, 2003
- Application of acoustic resonators in photoacoustic trace gas analysis and metrologyReview of Scientific Instruments, 2001
- Optische Spektroskopie2000
- THE HITRAN MOLECULAR SPECTROSCOPIC DATABASE AND HAWKS (HITRAN ATMOSPHERIC WORKSTATION): 1996 EDITIONJournal of Quantitative Spectroscopy and Radiative Transfer, 1998
- Luftschadstoffe in Innenräumen1996