Evaluation of the Dinamap 8100 and Omron M1 blood pressure monitors for use in children
- 1 April 2000
- journal article
- research article
- Published by Wiley in Paediatric and Perinatal Epidemiology
- Vol. 14 (2) , 179-186
Abstract
The aim of this study was to evaluate the Dinamap 8100 and the Omron M1 (the test devices) against standard criteria for use in children in a fieldwork setting. Device calibration and validation were carried out in accordance with the British Hypertension Society protocol for special groups such as children. A total of 102 children, recruited from infant and junior schools in Southampton, had six sequential measurements made of their blood pressure–four measurements with a mercury sphygmomanometer and two with one of two test devices, 55 children with the Dinamap 8100 and 47 with the Omron M1. Systolic and diastolic readings with the Dinamap 8100 were on average 11 mmHg higher (95% confidence interval [CI]+9, +12 mmHg) and 3 mmHg lower (95% CI −5, −1 mmHg), respectively, than measurements with the mercury sphygmomanometer, overestimating systolic pressures and underestimating diastolic pressures across the whole range observed. The Omron M1 gave readings lower by 1 mmHg on average for systolic pressures and 2 mmHg for diastolic pressures compared with the sphygmomanometer (95% CIs −4, +1 mmHg and −5, +1 mmHg respectively), specifically overestimating higher pressures and underestimating lower pressures. According to the criteria of the British Hypertension Society, neither the Dinamap 8100 nor the Omron M1 can be recommended for use in children in clinical situations in which accuracy of the absolute measurement is required. In epidemiological surveys, in which differences in blood pressure between groups of people are more important than absolute levels, it may be more appropriate to use these devices. Of the two, its more consistent performance supports the Dinamap 8100 as the instrument of choice in such studies of children.Keywords
This publication has 11 references indexed in Scilit:
- Inaccuracy of the Dinamap 8100 portable monitorThe Lancet, 1997
- Is blood pressure inversely related to birth weight? The strength of evidence from a systematic review of the literatureJournal Of Hypertension, 1996
- 19 An accurate automated device for home blood pressure measurement at last! The Omron HEM-705CPJournal Of Hypertension, 1994
- Short report: An outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devicesJournal Of Hypertension, 1993
- The Dinamap 1846SX automated blood pressure recorder: comparison with the Hawksley random zero sphygmomanometer under field conditions.Journal of Epidemiology and Community Health, 1992
- Blood pressure in first 10 years of life: the Brompton study.BMJ, 1992
- Childhood Precursors of High Blood Pressure and Elevated CholesterolAnnual Review of Public Health, 1991
- Inaccuracy of seven popular sphygmomanometers for home measurement of blood pressureJournal Of Hypertension, 1990
- Blood pressure, stroke, and coronary heart disease *1Part 1, prolonged differences in blood pressure: prospective observational studies corrected for the regression dilution biasThe Lancet, 1990
- Observer bias in blood pressure studiesJournal Of Hypertension, 1988