Assessing Inaccuracies in Automated Information Extraction of Breast Imaging Findings
Open Access
- 14 November 2016
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 30 (2) , 228-233
Abstract
We previously identified breast imaging findings from radiology reports using an expert-based information extraction algorithm as part of the National Cancer Institute’s Population-based Research Optimizing Screening through Personalized Regimens (PROSPR) initiative. We validate this algorithm and assess inaccuracies in a different institutional setting. Mammography, ultrasound (US), and breast magnetic resonance imaging (MRI) reports of patients at an academic health system between 4/2013 and 6/2013 were included for analysis. Accuracy of automatically extracting imaging findings using an algorithm developed at a different institution compared to manual gold standard review is reported. Extraction errors are further categorized based on manual review. Precision and recall for extracting BI-RADS categories remain between 0.9 and 1.0, except for MRI (0.7). F measures for extracting other findings are 0.9 for non-mass enhancement (in MRI) and 0.8–0.9 for cysts (in MRI and US). Extracting breast imaging findings resulted in lowest accuracy for findings of calcification (range 0.4–0.6 in mammography) and asymmetric density (0.5–0.7 in mammography). Majority of errors for extracting imaging findings were due to qualifier-based errors, descriptors which indicate absence of findings, missed by automated extraction (e.g., “benign” calcifications). Our information extraction algorithm provides an effective approach to extracting some breast imaging findings for populating a breast screening registry. However, errors in information extraction when utilizing methods in new settings demonstrate that further work is necessary to extract information content from unstructured multi-institutional radiology reports.Keywords
Funding Information
- National Cancer Institute (U54CA163307)
This publication has 24 references indexed in Scilit:
- Information from Searching Content with an Ontology-Utilizing Toolkit (iSCOUT)Journal of Digital Imaging, 2012
- Leveraging terminologies for retrieval of radiology reports with critical imaging findings.2011
- Young Age at Diagnosis Correlates With Worse Prognosis and Defines a Subset of Breast Cancers With Shared Patterns of Gene ExpressionJournal of Clinical Oncology, 2008
- Evaluation of biomedical text-mining systems: Lessons learned from information retrievalBriefings in Bioinformatics, 2005
- Mammographic Characteristics of 115 Missed Cancers Later Detected with Screening Mammography and the Potential Utility of Computer-aided DetectionRadiology, 2001
- Effective mapping of biomedical text to the UMLS Metathesaurus: the MetaMap program.2001
- Automatic Structuring of Radiology Free-Text ReportsRadioGraphics, 2001
- Role and evaluation of mammography and other imaging methods for breast cancer detection, diagnosis, and stagingSeminars in Nuclear Medicine, 1999
- Automatic extraction of PIOPED interpretations from ventilation/perfusion lung scan reports.1998
- Quality mammography standards--FDA. Final rule.1997