Did the use of the Guideliner V2TM guide catheter extension increase complications? A review of the incidence of complications related to the use of the V2 catheter, the influence of right brachiocephalic arterial anatomy and the redesign of the V3TM Guideliner and clinical outcomes
Authors:
Open Access
- 27 January 2016
- journal article
- review article
- Published by BMJ in Open Heart
- Vol. 3 (1) , e000331
Abstract
Objective We sought to investigate the incidence of complications associated with V2 Guideliner, understand the mechanisms and evaluate the impact of alterations made to the V3 Guideliner. Methods Retrospective analysis of consecutive cases employing V2 Guideliner from two university teaching hospitals. Complications were identified, analysed and classified into major versus minor ones. To understand the potential anatomical mechanism of these complications, analysis of normal great vessel anatomy was undertaken in separate cohort of patients undergoing cardiac catheterisation via right radial approach. Further analysis of consecutive cases employing V3 Gudieliner took place and the incidence of complications were compared between V2 and V3 groups. Results Total of 188 cases of V2 Guideliner use were identified. One major complication was reported (coronary dissection). Proximal collar interaction and stent damage occurred in 19 cases (10%). Anatomical data suggest that extending the V2 Guideliner tubing sited the proximal collar of the device in the brachiocephalic/subclavian artery, a potential site of tortuosity and potential cause of the Guideliner proximal collar-stent interaction. Further analysis of 124 cases of V3 Guideliner use demonstrated no cases with proximal collar-stent interactions, one case of longitudinal stent deformation and two incidents of stent interaction with the distal edge of the V3 Guideliner. Conclusions We have demonstrated a higher incidence of V2 Guideliner complications compared to previous series. The change in design of the V2 Guideliner was a likely contributor but the modifications with V3 Guideliner appear to have ameliorated this issue.Keywords
This publication has 6 references indexed in Scilit:
- Extended use of the GuideLiner in complex coronary interventionsEuroIntervention, 2015
- Usefulness and safety of the GuideLiner catheter to enhance intubation and support of guide catheters: insights from the Twente GuideLiner registryEuroIntervention, 2012
- Guideliner® catheter—Friend or foe?Catheterization and Cardiovascular Interventions, 2011
- Transfemoral use of the guideLiner catheter in complex coronary and bypass graft interventionsCatheterization and Cardiovascular Interventions, 2011
- The use of the GuideLiner™ catheter as a child-in-mother technique: an initial single-center experienceHeart and Vessels, 2011
- Distal stent delivery with guideliner catheter: First in man experienceCatheterization and Cardiovascular Interventions, 2010