Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Open Access
- 1 September 2015
- journal article
- Vol. 40 (5) , 418-424
Abstract
Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. 52 primary cementless total hip arthroplasty in 42 patients with the mean age of 48.8 years were retrospectively studied. Two groups of prosthesis had been implanted: Harris-Galante II (HGII) in 15 and Versys-Trilogy (V-T) in 37 hips, both from Zimmer company. The patients were assessed clinically, radiographically and with Harris hip score, SF36, WOMAC, and MACTAR questionnaires, with 65 months (26-136) mean follow-up. All the V-T prostheses had survived well. Eight of HG II were revised by the last follow-up in 19-102 months. All had undergone acetabular revision and 2 combined with femoral revision. Broken tines of HGII cups were seen in 4 radiographs. The 65 months overall survival was 96.2% for femoral and 84.6% for acetabular components. 90% had good or excellent Harris hip scores. The functional scores were poorer in the HG II group. Pain relief and improved walking were the two main patients’ expectations fulfilled in 97.6% and 92.8%, respectively. The outcome of cementless total hip arthroplasty (THA) is satisfactory and comparable with the literature based on the results of function and survival of this small comparative group. The use of HGII acetabular component should be abandoned.Keywords
This publication has 35 references indexed in Scilit:
- Acetabular Components in Total Hip Arthroplasty: Is There Evidence That Cementless Fixation Is Better?Journal of Bone and Joint Surgery, 2013
- Cementless acetabular revision: past, present, and futureInternational Orthopaedics, 2011
- The Long-Term Results of the Original Exeter Polished Cemented Femoral ComponentThe Journal of Arthroplasty, 2009
- Total Hip Arthroplasty with a Cemented, Polished, Collared Femoral Stem and a Cementless Acetabular ComponentJournal of Bone and Joint Surgery, 2007
- Long-term results of the cementless porous-coated anatomic total hip prosthesisThe Journal of Bone and Joint Surgery. British volume, 2005
- Long-Term Results of Use of the Anatomic Medullary Locking Prosthesis in Total Hip Arthroplasty*Journal of Bone and Joint Surgery, 1997
- The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection.1992
- The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series.Journal of Bone and Joint Surgery, 1988
- Loosening of the femoral component after total hip replacement. The thin black line and the sinking hip.1986
- Conventional total hip arthroplasty for degenerative joint disease in patients between the ages of forty and sixty years.Journal of Bone and Joint Surgery, 1984