Mechanical considerations for the syndesmosis screw. A cadaver study.
Authors:
- P A LabropoulosPLP A Labropoulos
- P McCowinPMP McCowin
- W F LestiniWLW F Lestini
- S R HurwitzSHS R Hurwitz
- 1 December 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 71 (10) , 1548-1555
Abstract
Mounted through the tibia to a frame so that multiple radiographs could be made with a constant relationship between the specimen and the x-ray apparatus. A standardized pronation-external rotation load was applied to the foot, and widening of the syndesmosis was studied on mortise radiographs that were made after each experimental step. On the basis of previous investigations, we developed a model for pronation-external rotation injuries that included disruption of the syndesmosis and interosseous membrane up to the level of the fibular fracture. Accordingly, multiple repaired fibular fractures could be simulated at several levels in the same specimen by incremental proximal division of the interosseous membrane. Specimens were separated into two groups. Group I consisted of thirteen specimens in which the deltoid ligament, syndesmosis, and interosseous membrane were serially sectioned in 1.5-centimeter increments. Group II (ten sections) was subjected to the same protocol, except that the deltoid ligament was kept intact until the final step. The five fresh specimens were sectioned in the same way as those in Group I. In Group I, since the simulated pronation-external rotation injury included a deltoid tear, rigid medial fixation was not possible; accordingly, there was rigid fibular fixation only.(ABSTRACT TRUNCATED AT 250 WORDS) The purpose of this study was to examine the mechanical necessity of using a syndesmosis screw to supplement rigid internal fixation of the fibula and medial malleolus in the treatment of pronation-external rotation fractures. The legs of thirty embalmed and five fresh cadavera were dissected and mounted through the tibia to a frame so that multiple radiographs could be made with a constant relationship between the specimen and the x-ray apparatus. A standardized pronation-external rotation load was applied to the foot, and widening of the syndesmosis was studied on mortise radiographs that were made after each experimental step. On the basis of previous investigations, we developed a model for pronation-external rotation injuries that included disruption of the syndesmosis and interosseous membrane up to the level of the fibular fracture. Accordingly, multiple repaired fibular fractures could be simulated at several levels in the same specimen by incremental proximal division of the interosseous membrane. Specimens were separated into two groups. Group I consisted of thirteen specimens in which the deltoid ligament, syndesmosis, and interosseous membrane were serially sectioned in 1.5-centimeter increments. Group II (ten sections) was subjected to the same protocol, except that the deltoid ligament was kept intact until the final step. The five fresh specimens were sectioned in the same way as those in Group I. In Group I, since the simulated pronation-external rotation injury included a deltoid tear, rigid medial fixation was not possible; accordingly, there was rigid fibular fixation only.(ABSTRACT TRUNCATED AT 250 WORDS) Copyright © 1989 by The Journal of Bone and Joint Surgery, Incorporated...Keywords
This publication has 10 references indexed in Scilit:
- The effect of the syndesmotic screw on the extension capacity of the ankle jointArchives of orthopaedic and trauma surgery, 1985
- Ligamentous injury of the lower tibiofibular syndesmosis: radiographic evidence.Radiology, 1985
- Instability of the distal tibiofibular syndesmosis after bimalleolar and trimalleolar ankle fractures.Journal of Bone and Joint Surgery, 1984
- Quantitative criteria for prediction of the results after displaced fracture of the ankle.Journal of Bone and Joint Surgery, 1983
- Distal Tibiofibular Ligaments:Analysis of FunctionActa Orthopaedica, 1982
- INFERIOR TIBIO-FIBULAR DIASTASIS TREATED BY STAPLE FIXATION1981
- The Lauge Hansen Classification of Malleolar FracturesActa Orthopaedica, 1980
- Fractures of the fibula proximal to the distal tibiofibular syndesmosis.Journal of Bone and Joint Surgery, 1978
- The key role of the lateral malleolus in displaced fractures of the ankleJournal of Bone and Joint Surgery, 1977
- The Mechanical and Structural Characteristics of the Tibio-Fibular Interosseous MembraneActa Orthopaedica, 1976