Impact of charge transfer inefficiency on transit light curves
Open Access
- 13 March 2026
- journal article
- research article
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 707, A200
Abstract
Context . PLATO is designed to detect Earth-sized exoplanets orbiting solar-type stars and to measure their radii (relative to the star radii) with an accuracy better than 2% via the transit method. Charge transfer inefficiency (CTI), a by-product of radiation damage to charge-coupled devices (CCDs), can jeopardise this accuracy constraint and therefore must be corrected to reach scientific requirements. Aims . We assessed and quantified the impact of CTI on transit depth measurements. Our objective was to demonstrate the need for CTI correction and to develop a correction strategy that restores CTI-biased transit depths with an acceptable residual within the accuracy budget. Methods . Using a calibration dataset generated with PLATOSim to simulate a realistic stellar field, we modelled the parallel overscan signal as the sum of exponential decays and used least-squares fitting to infer the number of trap species and initial estimates for the release times ( τ r,k ). Smearing was then modelled with an exponential-plus-constant function and removed on a column-wise basis. We modelled the spatial variation in the trap density with a quadratic polynomial function of the radial distance from the centre of the focal plane. The polynomial coefficients ( a p,k ) of this model, the well-fill power index ( β ), and the release times ( τ r,k ) were subsequently adjusted via an iterative application of the extended pixel edge response method combined with a CTI correction algorithm. This yielded the final calibration model that underpins our correction strategy. Results . In the worst-case scenario (8-year mission, high CTI impact zone), we found that CTI induced a bias of approximately 4% in the measured transit depth. The polynomial coefficients from our trap density model were then used to correct the CTI-affected transit depths. Our correction reduced the bias to a residual of 0.06%, which is comfortably within PLATO’s accuracy requirements. Conclusions . We quantified the CTI-induced bias in transit depth measurements and implemented a calibration strategy that incorporates spatial variations in trap density. From the calibrated parameters, we derived a correction scheme that brought the photometric measurements within PLATO’s noise budget, ensuring that the mission’s precision requirements are met.Keywords
All Related Versions
Funding Information
- France 2030 (ANR-23-CMAS-0041)
This publication has 15 references indexed in Scilit:
- The PLATO missionExperimental Astronomy, 2025
- Investigation of an irradiated CCD device: Building and testing a Charge Transfer Inefficiency correction pipeline using the Pyxel frameworkNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2024
- PlatoSim: an end-to-end PLATO camera simulator for modelling high-precision space-based photometryAstronomy & Astrophysics, 2024
- Array programming with NumPyNature, 2020
- SciPy 1.0: fundamental algorithms for scientific computing in PythonNature Methods, 2020
- In-flight photometry extraction of PLATO targetsAstronomy & Astrophysics, 2019
- The PLATO Solar-like Light-curve SimulatorAstronomy & Astrophysics, 2019
- An analytical model of radiation-induced Charge Transfer Inefficiency for CCD detectorsMonthly Notices of the Royal Astronomical Society, 2013
- KeplerPresearch Data Conditioning II - A Bayesian Approach to Systematic Error CorrectionPublications of the Astronomical Society of the Pacific, 2012
- Analytic Light Curves for Planetary Transit SearchesThe Astrophysical Journal, 2002