Evaluation of the new restandardized Abbott Architect 25‐OH Vitamin D assay in vitamin D‐insufficient and vitamin D‐supplemented individuals
Authors:
- 19 September 2017
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 32 (4) , e22328
Abstract
Background: Recently, Abbott Diagnostics has restandardized the Architect 25(OH)D assay against the NIST SRM 2972. We have evaluated the analytical and clinical performance of the restandardized Architect 25(OH)D assay and compared its performance with a NIST‐traceable liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) method and the Roche total 25(OH)D assay in vitamin D‐insufficient individuals before and after vitamin D3 supplementation.Methods: Frozen serum samples were obtained from 88 healthy subjects with self‐perceived fatigue and vitamin D‐insufficiency −1 who were randomized to receive a single 100 000 IU dose of vitamin D3 (n = 48) or placebo (n = 40). Total 25(OH)D concentrations were measured before and 4 weeks after supplementation by the restandardized Architect 25(OH)D assay, LC‐MS/MS, and Roche assay.Results: The Architect 25(OH)D assay showed an intra‐ and inter‐assay imprecision of −1) with a mean negative bias of 17.1%, this negative bias turned into a positive bias in supplemented subjects. Overall there was a moderate agreement in classification of vitamin D‐insufficient and ‐supplemented individuals into different vitamin D states between the Architect 25(OH)D method and LC‐MS/MS.Conclusion: The routine use of the restandardized Architect 25(OH)D results in a slight underestimation of circulating total 25(OH)D levels at lower concentrations and thus potential misclassification of vitamin D status.Keywords
This publication has 14 references indexed in Scilit:
- Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assaysClinical Chemistry and Laboratory Medicine (CCLM), 2016
- Performance characteristics of six automated 25-hydroxyvitamin D assays: Mind your 3s and 2sClinical Biochemistry, 2015
- Analytical Bias in the Measurement of Serum 25-Hydroxyvitamin D Concentrations Impairs Assessment of Vitamin D Status in Clinical and Research SettingsPLOS ONE, 2015
- Analytical and clinical evaluation of the new Fujirebio Lumipulse®G non-competitive assay for 25(OH)-vitamin D and three immunoassays for 25(OH)D in healthy subjects, osteoporotic patients, third trimester pregnant women, healthy African subjects, hemodialyzed and intensive care patientsClinical Chemistry and Laboratory Medicine (CCLM), 2015
- 25-Hydroxy-Vitamin D Status: Limitations in Comparison and Clinical Interpretation of Serum-Levels Across Different Assay MethodsClinical Laboratory, 2014
- Agreement of seven 25-hydroxy vitamin D3 immunoassays and three high performance liquid chromatography methods with liquid chromatography tandem mass spectrometryClinical Chemistry and Laboratory Medicine (CCLM), 2014
- Vitamin D Assays: Past and Present Debates, Difficulties, and DevelopmentsCalcified Tissue International, 2013
- State-of-the-Art Vitamin D Assays: A Comparison of Automated Immunoassays with Liquid Chromatography–Tandem Mass Spectrometry MethodsClinical Chemistry, 2012
- 25-Hydroxyvitamin D Assays: The Quest For AccuracyClinical Chemistry, 2009
- Candidate Reference Method for the Quantification of Circulating 25-Hydroxyvitamin D3 by Liquid Chromatography–Tandem Mass SpectrometryClinical Chemistry, 2004