Mapping conduction velocity of early embryonic hearts with a robust fitting algorithm
- 18 May 2015
- journal article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (6) , 2138-2157
Abstract
Cardiac conduction maturation is an important and integral component of heart development. Optical mapping with voltage-sensitive dyes allows sensitive measurements of electrophysiological signals over the entire heart. However, accurate measurements of conduction velocity during early cardiac development is typically hindered by low signal-to-noise ratio (SNR) measurements of action potentials. Here, we present a novel image processing approach based on least squares optimizations, which enables high-resolution, low-noise conduction velocity mapping of smaller tubular hearts. First, the action potential trace measured at each pixel is fit to a curve consisting of two cumulative normal distribution functions. Then, the activation time at each pixel is determined based on the fit, and the spatial gradient of activation time is determined with a two-dimensional (2D) linear fit over a square-shaped window. The size of the window is adaptively enlarged until the gradients can be determined within a preset precision. Finally, the conduction velocity is calculated based on the activation time gradient, and further corrected for three-dimensional (3D) geometry that can be obtained by optical coherence tomography (OCT). We validated the approach using published activation potential traces based on computer simulations. We further validated the method by adding artificially generated noise to the signal to simulate various SNR conditions using a curved simulated image (digital phantom) that resembles a tubular heart. This method proved to be robust, even at very low SNR conditions (SNR = 2-5). We also established an empirical equation to estimate the maximum conduction velocity that can be accurately measured under different conditions (e.g. sampling rate, SNR, and pixel size). Finally, we demonstrated high-resolution conduction velocity maps of the quail embryonic heart at a looping stage of development.Keywords
Funding Information
- National Institutes of Health (RO1HL083048, R01HL095717, R21HL115373, K99HL112724)
- Ohio Wright Center of Innovation and Biomedical Research and Technology Transfer award
- The Biomedical Structure, Functional and Molecular Imaging Enterprise
This publication has 48 references indexed in Scilit:
- Bloomsbury report on mouse embryo phenotyping: recommendations from the IMPC workshop on embryonic lethal screeningDisease Models & Mechanisms, 2013
- Notch signaling regulates murine atrioventricular conduction and the formation of accessory pathwaysJournal of Clinical Investigation, 2011
- Optical pacing of the embryonic heartNature Photonics, 2010
- Wnt11 patterns a myocardial electrical gradient through regulation of the L-type Ca2+ channelNature, 2010
- Development of the cardiac conduction systemSeminars in Cell & Developmental Biology, 2007
- Optical Mapping of Electrical Activation in the Developing HeartMicroscopy and Microanalysis, 2005
- Emerging patterns of cardiac conduction in the chick embryo: Waveform analysis with photodiode array‐based optical imagingDevelopmental Dynamics, 2005
- Functional pacemaking area in the early embryonic chick heart assessed by simultaneous multiple-site optical recording of spontaneous action potentials.Journal of General Physiology, 1988
- The design of digital filters for biomedical signal processing Part 3: The design of Butterworth and Chebychev filtersJournal of Biomedical Engineering, 1983
- Myocardial cell shape change as a mechanism of embryonic heart loopingDevelopmental Biology, 1972