Abstract
To advance the application of continuum robots in the medical field, this study proposes the integration of compliant bi‐stability in continuum robots to enable the ability to form custom shapes. The process includes designing a compliant bistable mechanism (CBM), deconstructing a ball‐joint‐based continuum robot segment, and then integrating the two. This allows the resultant continuum segment to become bistable. Two versions of this CBM‐integrated continuum segment arose from the design process: an “Extending” version that improves the effective length and reachability of the segments, and a “Locking” version that locks certain regions and enhances stiffness. When used together, these two segment types enable the CBM‐based continuum robot to demonstrate mechanical intelligence by achieving custom shapes in different configurations through passive mechanical design. The paper also presents an analytical model to characterize the CBM. Simulation and experimental results for the segments establish a 50% increase in workspace by using the extending segment. Using the locking segment results in an 80% to 100% increase in stiffness. A shape formation test for a liver biopsy procedure shows a decrease of 61% in the tip‐to‐target deviation, demonstrating a potential application for minimally invasive surgeries.Keywords
Funding Information
- National Research Foundation of Korea (RS‐2021‐NR059747)
- Ministry of Trade, Industry and Energy (20023168)
- Ministry of Trade, Industry and Energy (RS‐2024‐00423853)
This publication has 54 references indexed in Scilit:
- Variable stiffness methods of flexible robots for minimally invasive surgery: A reviewBiomimetic Intelligence and Robotics, 2024
- Continuum Robots: An OverviewAdvanced Intelligent Systems, 2023
- A Novel Distal Hybrid Pneumatic/Cable‐Driven Continuum Joint with Variable Stiffness Capacity for Flexible Gastrointestinal EndoscopyAdvanced Intelligent Systems, 2023
- Magnetically Actuated Continuum Medical Robots: A ReviewAdvanced Intelligent Systems, 2023
- Bistable, Pneumatically Actuated Microgripper Fabricated Using Two‐Photon Polymerization and Oxygen Plasma EtchingAdvanced Intelligent Systems, 2023
- A Soft Growing Robot Using Hyperelastic MaterialAdvanced Intelligent Systems, 2022
- Endoscopic Ultrasound-Guided Liver Biopsy in Clinical PracticeGastro Hep Advances, 2022
- A Switchable Dual‐Mode Actuator Enabled by Bistable StructureAdvanced Intelligent Systems, 2022
- Robot-Assisted Uterine Artery Embolization: A First-in-Woman Safety Evaluation of the Magellan SystemJournal of Vascular and Interventional Radiology, 2014
- Robot-assisted Fenestrated Endovascular Aneurysm Repair (FEVAR) Using the Magellan SystemJournal of Vascular and Interventional Radiology, 2013