Brain iron detected by SWI high pass filtered phase calibrated with synchrotron X‐ray fluorescence
Authors:
Open Access
- 24 May 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 31 (6) , 1346-1354
Abstract
Purpose: To test the ability of susceptibility weighted images (SWI) and high pass filtered phase images to localize and quantify brain iron. Materials and Methods: Magnetic resonance (MR) images of human cadaver brain hemispheres were collected using a gradient echo based SWI sequence at 1.5T. For X‐ray fluorescence (XRF) mapping, each brain was cut to obtain slices that reasonably matched the MR images and iron was mapped at the iron K‐edge at 50 or 100 μm resolution. Iron was quantified using XRF calibration foils. Phase and iron XRF were averaged within anatomic regions of one slice, chosen for its range of iron concentrations and nearly perfect anatomic correspondence. X‐ray absorption spectroscopy (XAS) was used to determine if the chemical form of iron was different in regions with poorer correspondence between iron and phase. Results: Iron XRF maps, SWI, and high pass filtered phase data in nine brain slices from five subjects were visually very similar, particularly in high iron regions. The chemical form of iron could not explain poor matches. The correlation between the concentration of iron and phase in the cadaver brain was estimated as cFe [μg/g tissue] = 850Δϖ + 110. Conclusion: The phase shift Δϖ was found to vary linearly with iron concentration with the best correspondence found in regions with high iron content. J. Magn. Reson. Imaging 2010;31:1346–1354.Keywords
This publication has 43 references indexed in Scilit:
- Magnetic field correlation as a measure of iron‐generated magnetic field inhomogeneities in the brainMagnetic Resonance in Medicine, 2009
- Tracing Copper−Thiomolybdate Complexes in a Prospective Treatment for Wilson’s DiseaseBiochemistry, 2009
- An iterative reconstruction technique for geometric distortion-corrected segmented echo-planar imagingMagnetic Resonance Imaging, 2008
- Increased Levels of Magnetic Iron Compounds in Alzheimer's DiseaseJournal of Alzheimer’s Disease, 2008
- Age-Dependent Normal Values of T2* and T2′ in Brain ParenchymaAmerican Journal of Neuroradiology, 2008
- Establishing a baseline phase behavior in magnetic resonance imaging to determine normal vs. abnormal iron content in the brainJournal of Magnetic Resonance Imaging, 2007
- Role of Iron in Neurodegenerative DisordersTopics in Magnetic Resonance Imaging, 2006
- Clinical applications of neuroimaging with susceptibility‐weighted imagingJournal of Magnetic Resonance Imaging, 2005
- Imaging iron stores in the brain using magnetic resonance imagingMagnetic Resonance Imaging, 2005
- Formalin fixed brains are useful for magnetic resonance imaging (MRI) studyJournal of the Neurological Sciences, 1987