Multiple electrode piezoelectric micromachined ultrasonic transducers
Authors:
- 1 September 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 305-308
Abstract
Piezoelectric micromachined ultrasonic transducers (pMUTs) with multiple electrodes were shown to have enhanced effective electromechanical coupling factors, about 211% larger than that of the state-of-the-art, single electrode design. In this work, a theoretical model of the electromechanical coupling is developed for the circular-shape, clamped unimorph pMUTs and validated with published experimental results on single electrode structures. A 4-electrode design with a 5 μm-thick poly-Si structural layer, 2 μm-thick PZT piezoelectric layer, and 135 μm in radius has an effective electromechanical coupling of 13.72%, which is 211% higher than that of a conventional single-electrode pMUT. As such, multiple electrode pMUTs could replace the state-of-art, single-electrode pMUTs for high electromechanical coupling in various ultrasonic transduction applications, such as gesture recognition and medical imaging.Keywords
This publication has 16 references indexed in Scilit:
- Improved acoustic coupling of air-coupled micromachined ultrasonic transducers2014
- Highly responsive curved aluminum nitride pMUT2014
- Analytic solution for N-electrode actuated piezoelectric disk with application to piezoelectric micromachined ultrasonic transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Three-dimensional micro electromechanical system piezoelectric ultrasound transducerApplied Physics Letters, 2012
- Theoretical modeling and equivalent electric circuit of a bimorph piezoelectric micromachined ultrasonic transducerIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- A micromechanical ultrasonic distance sensor with >1 meter range2011
- Enhanced actuation and acoustic transduction by pressurization of micromachined piezoelectric diaphragmsSensors and Actuators A: Physical, 2010
- 5I-2 Thick PZT Sol-Gel Films for pMUT Transducers Performances Improvement2006
- Piezoelectric micromachined ultrasonic transducers based on PZT thin filmsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- Calculation and measurement of electromechanical coupling coefficient of capacitive micromachined ultrasonic transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2003