Biomechanical study of a prosthetic solution based on an angled abutment: Case of upper lateral incisor
Authors:
- M. DaasMDM. Daas
- A.S. BonnetABA.S. Bonnet
- P. LipinskiPLP. Lipinski
- 8 December 2006
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 29 (9) , 989-998
Abstract
To study the complex behaviour of an upper lateral incisor restoration using an angled abutment, a mechanical analysis of the abutment bearing capacity was firstly carried out. The evolution of bone properties around implant was then simulated as a function of time to estimate the maximal load that could be supported by the prosthetic solution without bone damage. According to the Food and Drug Administration procedure, experimental tests were firstly carried out on five samples. A 25 degrees -angled abutment screwed to an implant embedded into a massive steel bloc was submitted to a static loading. Two finite element models were also built: the first one (I) to interpret and complete the results obtained in the experimental part and the second one (II) to simulate bone remodelling around implant considering a strain energy stimulus. According to experiments, the abutment straightening was observed for an average force of 869N. Numerical model (I) confirmed this result and indicated that the initial irreversible deformation (yielding) of abutment was obtained for a 283N compressive force. It could thus be deduced that this abutment can safely be used for an incisor restoration. Model (II) showed that, after 26 months, some of the cancellous bone initially present in an approximately one millimetre thick shell surrounding the implant had reached the density of cortical bone. A safe load notion corresponding to the force leading to the maximal admissible strain value for trabecular bone was introduced. It evolved from 44N after surgery to approximately 160N after 26 months.Keywords
This publication has 33 references indexed in Scilit:
- Peri-implant osteogenesis in health and osteoporosisMicron, 2005
- Bone reactions to longstanding functional load at implants: an experimental study in dogsJournal of Clinical Periodontology, 2005
- A radiographic assessment of progressive loading on bone around single osseointegrated implants in the posterior maxillaClinical Oral Implants Research, 2004
- Modelling bone tissue fracture and healing: a reviewEngineering Fracture Mechanics, 2004
- Numerical study of shear deformation in Ti–6Al–4V at medium and high strain rates, critical impact velocity in shearInternational Journal of Impact Engineering, 2002
- Immediate loading of single‐tooth ITI implants in the anterior maxilla: a prospective 5‐year pilot studyClinical Oral Implants Research, 2002
- Biomechanical characterization of osseointegration: An experimental in vivo investigation in the beagle dogJournal of Orthopaedic Research, 1998
- Cancellous Bone Young’s Modulus Variation Within the Vertebral Body of a Ligamentous Lumbar Spine—Application of Bone Adaptive Remodeling ConceptsJournal of Biomechanical Engineering, 1995
- A Three‐Dimensional Finite Element Stress Analysis of Angled Abutments for an Implant Placed in the Anterior MaxillaJournal of Prosthodontics, 1995
- Trabecular bone exhibits fully linear elastic behavior and yields at low strainsJournal of Biomechanics, 1994