Abstract
Background and Aims: The baseline radiostereometric analysis (RSA) is usually performed during the first postoperative week. We investigated the micromotion of two uncemented press fit acetabular cups during the first week after total hip arthroplasty. Material and Methods: All study patients had unilateral osteoarthritis of the hip and received an uncemented THA combination consisting of a CLS stem and either an Allofit or an Interop acetabular cup. The study group consisted of 24 patients who underwent RSA within 1 hour after skin closure, and at 1 and 7 days after surgery. Results: The upper limit of the 95% confidence interval for micromotion was less than or close to the precision of the method for all studied directions during the first week after surgery. Mean values indicate proximal and medial translation of the uncemented cup at one week. Conclusions: We found only minimal micromotion, barely above the precision limit, measured as medial and proximal translations of these uncemented cups. This indicates that the first postoperative RSA measurement following a primary THA with an uncemented press fit acetabular cup should be made as early as possible after the first postoperative day.Keywords
This publication has 18 references indexed in Scilit:
- Immediate weight bearing after uncemented total hip arthroplasty with an anteverted stem: A prospective randomized comparison using radiostereometryActa Orthopaedica, 2007
- Early Migration Pattern of the Uncemented CLS Stem in Total Hip ArthroplastiesClinical Orthopaedics and Related Research, 2007
- No difference in migration or wear between cemented low-profile cups and standard cups : A randomized radiostereographic study of 53 patients over 3 yearsActa Orthopaedica, 2007
- Early Aseptic Loosening of a Modern Acetabular Component Secondary to a Change in ManufacturingThe Journal of Arthroplasty, 2006
- Guidelines for standardization of radiostereometry (RSA) of implantsActa Orthopaedica, 2005
- Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis.Journal of Bone and Joint Surgery, 1994
- In vivo Messung der Hüftgelenkbelastung 1. Teil: KrankengymnastikZeitschrift für Orthopädie und ihre Grenzgebiete, 1989
- Roentgen stereophotogrammetry: Review of orthopedic applicationsActa Orthopaedica, 1989
- Roentgen stereophotogrammetryActa Orthopaedica, 1989
- Stability of femoral neck fractures: A postoperative roentgen stereophotogrammetric analysisActa Orthopaedica, 1989