Determination of the optimal first‐order gradient moment for flow‐sensitive dephasing magnetization‐prepared 3D noncontrast MR angiography
Authors:
Open Access
- 24 February 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 65 (4) , 964-972
Abstract
Flow‐sensitive dephasing (FSD) magnetization preparation has been developed for black‐blood vessel wall MRI and noncontrast MR angiography. The first‐order gradient moment, m1, is a measure of the flow‐sensitization imparted by an FSD preparative module. Determination of the optimal m1 for each individual is highly desirable for FSD‐prepared MR angiography. This work developed a 2D m1‐scouting method that evaluates a range of m1 values for their effectiveness in blood signal suppression in a single scan. The feasibility of using the 2D method to predict blood signal suppression in 3D FSD‐prepared imaging was validated on a flow phantom and the popliteal arteries of 5 healthy volunteers. Excellent correlation of the blood signal measurements between the 2D scouting and 3D FSD imaging was obtained. Therefore, the optimal m1 determined from the 2D m1‐scouting scan may be directly translated to 3D FSD‐prepared imaging. In vivo studies of additional 10 healthy volunteers and 2 patients have demonstrated the proposed method can help significantly improve the signal performance of FSD MR angiography, indicating its potential to enhance diagnostic confidence. Further systematic studies in patients are warranted to evaluate its clinical value. Magn Reson Med, 2011.Keywords
Funding Information
- National Institutes of Health (1R01HL096119)
This publication has 16 references indexed in Scilit:
- Nonenhanced MR Angiography of the Hand with Flow-Sensitive Dephasing–prepared Balanced SSFP Sequence: Initial Experience with Systemic SclerosisRadiology, 2011
- 3D noncontrast MR angiography of the distal lower extremities using flow‐sensitive dephasing (FSD)‐prepared balanced SSFPMagnetic Resonance in Medicine, 2009
- Effective motion‐sensitizing magnetization preparation for black blood magnetic resonance imaging of the heartJournal of Magnetic Resonance Imaging, 2008
- Noise Measurement and Estimation in MR Imaging ExperimentsRadiology, 2007
- Improved suppression of plaque‐mimicking artifacts in black‐blood carotid atherosclerosis imaging using a multislice motion‐sensitized driven‐equilibrium (MSDE) turbo spin‐echo (TSE) sequenceMagnetic Resonance in Medicine, 2007
- Diffusion-Prepared Segmented Steady-State Free Precession: Application to 3D Black-Blood Cardiovascular Magnetic Resonance of the Thoracic Aorta and Carotid Artery WallsJournal of Cardiovascular Magnetic Resonance, 2007
- Lipid-Rich Atherosclerotic Plaques Detected by Gadofluorine-Enhanced In Vivo Magnetic Resonance ImagingCirculation, 2004
- Flow effects in balanced steady state free precession imagingMagnetic Resonance in Medicine, 2003
- Pulsed arterial spin labeling using TurboFLASH with suppression of intravascular signalMagnetic Resonance in Medicine, 2003
- A Comparison between Different Imaging Strategies for Diffusion Measurements with the Centric Phase-Encoded TurboFLASH SequenceJournal of Magnetic Resonance, 1997